Newport Oil-Fired Heater

Page 11

SECTION 2.
Replacement Parts

2.1  Ordering Information

To order or purchase parts for Laars products, 

contact your nearest Laars dealer of distributor. If they 
cannot supply you with what you need, contact Laars 
Customer Service at the address shown on the back 
cover of this manual.

Visit our website at 

www.Laars.com 

for Service 

Center listings.

2.2  Parts List

Part Number        Description                                     Size

52-002                  Boiler Body ................................... 85/110
51-056                  Base Assembly  ............................ 85/110
                                (after 1990 - includes 51-058 panel)
51-058                  Burner Panel Assembly ................ 85/110
                                Use with P/N 51-056
51-090                  Flue Cover Assembly.................... 85/110
52-108                  Front Panel Assembly .................. 85/110
52-116                  Left Panel Assembly ..................... 85/110
52-124                  Right Panel Assembly .................. 85/110
51-128                  Top Panel Assembly..................... 85/110
52-136                  Rear Panel Assembly ................... 85/110
51-088                  Chamber ....................................... 85/110
51-053                  Baffle, 85-115 (14), 125-155 (18),
                                175-200 (30)  .................................... All

Part Number        Description                                     Size

54-002                  Boiler Body ................................. 125/150
53-056                  Base Assembly  .......................... 125/150
                                (after 1990 - includes 53-058 panel)
53-058                  Burner Panel Assembly  ............. 125/155
                                Use with p/n 53-0560
53-090                  Flue Cover Assembly.................. 125/150
54-108                  Front Panel Assembly ................ 125/150
54-116                  Left Panel Assembly ................... 125/150
54-124                  Right Panel Assembly ................ 125/150
53-128                  Top Panel Assembly................... 125/155
54-136                  Rear Panel Assembly ................. 125/155
53-088                  Chamber ..................................... 125/150

OUT OF

PRODUCTION

Содержание newport

Страница 1: ...ich could cause serious injury property damage or death Improper installation and or operation will void the warranty WARNING If the information in this manual is not followed exactly a fire or explos...

Страница 2: ...er normally fitted 4 1 10 Installation of Alternate Nozzles for Higher Output 4 1 11 Boiler Controls normally fitted 3 1 12 Oil 3 1 13 Oil Storage and Pipe Layout 3 1 14 Electrical Wiring 4 1 15 Opera...

Страница 3: ...gnee 1 3 Boiler Location The boiler should be positioned as near to the chimney as possible and have a minimum smoke pipe connector length of 18 457mm CAUTION Newport boilers must not be directly conn...

Страница 4: ...unit Important Refer to burner pump instructions for detailed fuel line and pump usage information All installations must conform to local and national codes See Figures 5A and 5B Figure 5A One pipe...

Страница 5: ...tire flue and venting system inspected 1 17 Cleaning the Boiler To maintain the high thermal efficiency and a long life from your boiler it should be cleaned at least once a year preferably at the end...

Страница 6: ...be causing a blockage 1 19 Servicing the Burner This should only be carried out by a trained and licensed service technician in accordance with the burner maker s instructions 1 20 Maintenance of the...

Страница 7: ...35 133 30 150 44 160 47 177 52 Output MBTU hr kW 90 26 105 30 116 34 130 38 139 40 154 48 Efficiency AFUE 83 6 83 1 83 1 83 7 83 0 83 0 Net Stack Temperature F C 312 156 353 178 371 188 351 177 386 1...

Страница 8: ...front panel 3 with screws 2 Slide assembled jacket over boiler and secure side panels to base tray 3 Fix rear panel 4 to sides 4 Adjust corner brackets 5 on heat exchanger so they touch inside of jack...

Страница 9: ...rmation Air vent Fill pipe Valve Figure 5A 1 min Oil tank H Filter P Burner Boiler Air vent 1 min Fill pipe Oil tank Figure 5B Valve Filter Burner Boiler H PIPE LENGTHS H One Pipe Gravity System 3 8 O...

Страница 10: ...verload protection as required 24V Room Thermostat 1K L1 Hot Power Supply 120V L2 Circulator Switch Low Limit Circulator Hi Limit 1K2 Oil Burner Relay Heating Circulator AQUASTAT RELAY L8124A 1K1 WIRI...

Страница 11: ...85 110 Use with P N 51 056 51 090 Flue Cover Assembly 85 110 52 108 Front Panel Assembly 85 110 52 116 Left Panel Assembly 85 110 52 124 Right Panel Assembly 85 110 51 128 Top Panel Assembly 85 110 5...

Страница 12: ...Fax 800 559 1583 Customer Service Service Advisors 20 Industrial Way Rochester NH 03867 603 335 6300 Fax 603 335 3355 1869 Sismet Road Mississauga Ontario Canada L4W 1W8 905 238 0100 Fax 905 366 0130...

Отзывы: