Mascot ST Tankless Water Heater
Page 23
Model
MSTWW199
Maximum Input
(BTU/H)
199,000
Indoor make up air is
provided, a minimum free
area of 1 in 2 per
1,000 BTU/H
199 in 2
14 1/4"
(W) x
14 1/4" (H)
All Terminations:
• After connecting terminals, install vent
screens on both the vent and air inlet.
4.7.3 Single Venting
Read and Follow Sections 4.3 Guidelines First.
1. Insert the termination end cap into the intake air
duct.
2. Provide two openings to allow for circulation of
combustion air as specified by ANSI Z224.1/NFPA
54 or CAN/CGA B-149.1:
4.8
Vent / Air Pipe Termination
Vertical Vent Termination
• Direct Vent - Vertical Terminations
with Sloped Roof
Vent Screens
are required
Two 3” vent screens are included with each unit.
Additional replacement screens are available for
purchase.
2” Vent Screen P/N - FT1508
3” Vent Screen P/N - FT1730