33
Installation Instructions
Everhot Horizontal Discharge Vent System
Identify the vent location
Figure 32
Steps:
- Place horizontal discharge adapter on water heater
- Mark position on wall
- Or use template provided with water heater
- Cut hole, covering the top of the water heater to prevent debris from entering
Measure dimension to fit
Figure
34
Figure 33
NOTICE
Note: if the vent system is shorter than 5 ft. (1,52 m) and no condensate collector is installed, be
sure to install the wall terminal with a 1° angle to the outside of the building.
NOTICE
Note: 3.5” (90 mm) is the minimum outer cap length. If needed the length outside the wall may
exceed this dimension.