MANAGEMENT OF OPERATING WARNINGS:
DELIVERY GROUP TEMPERATURE NOT REACHED WARNING
Appliance-stopping warning. If during the delivery group’s initial heating phase, the temperature does not reach at least 50°C within 8 minutes,
the
icon will appear in the place where relative group temperature is displayed.
Reset the warning by turning off and switching the respective group back on, using button 5 (PAGE 4).
GROUP TEMPERATURE TOO HIGH WARNING
Appliance-stopping warning. When the temperature detected by the delivery group’s temperature probe exceeds 140°C, the
icon will
appear in the place
where group temperature is displayed.
Reset the warning by turning off and switching the respective group back on, using button 5 (PAGE 4).
STEAM BOILER PRESSURE NOT REACHED WARNING
Steam boiler-stopping warning only. If, when the steam boiler is turned on at the start of the day, the pressure does not reach 0.5 bars in 20
minutes, the
icon will appear in the place of the steam boiler on/off button.
The warning is reset by pressing (turning off) this button on the main display.