S1 Owner’s Manual
Page 4
Contact your S1 vendor for advice
if the solution isn’t obvious. Also, your S1 vendor
may request that you check that your water hardness is below a certain level to ensure
long life and trouble free operation. Hardness test strips may be included for this
purpose. If your water fails this test, contact your S1 dealer and discuss the available
options.
Once water supply is properly attached, turned on, and the desired basket has been
inserted into one of the portafilter handles, attach the portafilter to the group. Be sure
that the drip tray is installed by sliding it into place at the bottom front of the machine.
3.3 Turning On and Heating the Machine
1) Insert the plug into the 110V AC socket, the On/STBY light (22) starts flashing to
show the connection to the electric network (Stand-by mode).
2) Press the ON / OFF (27) button and keep it pressed for about 3 seconds, the
green On/STBY light (22) changes from flashing to steady indicating the machine
is ON. At the same time the lights from (14) to (21) turn on steadily for about a
second (indicating power on test mode).
3) The light corresponding to the set temperature starts flashing to indicate that the
group is heating and the automatic boiler refill starts until the water level preset
by the manufacturer is reached.
4) Once the filling process is finished, the boiler light (13) starts flashing to indicate
that the boiler is heating. However, after first switching on, the boiler doesn't
work until the group has reached the set temperature.
5) Fasten the portafilter handle (11) to the brewing group (10).
6) Wait until the set temperature is reached, by checking that the lights on the
control panel (9) gradually turn on as the temperature rises. The visualization
starts as soon as the temperature reaches 85°C (turning on of light 14) and
continues until the machine has reached its operating temperature (light from
flashing to fixed).
7) When the group has reached the set temperature, the boiler heating starts (boiler
light (13) flashing), once it reaches the set temperature the light becomes fixed.
8) Every time the group temperature or the boiler temperature drops under the set
value, the respective light starts flashing (heating phase) until the set
temperature is reached.
9) The machine is now ready.