ALARM HISTORY
Alarm history
1
X - YYYYY JJ Z
YY-MM-DD HH:MM
Alarm history
1
X - YYYYY JJ Z
YY-MM-DD HH:MM
Enter
+ / -
Esc
1 - 10 : is the sequence number of the alarm
X : is the alarm number
YYYYY : is the description of the alarm
JJ : is the code of the alarm
Z : is the number of times the alarm occurred in a row ( 2 - 255 )
YY-MM-DD : Indicates the date of the alarm .
HH:MM : Indicates the clock of the alarm
: indicates that the alarm
has already been inspected
by technician
Alarm history
10
X - YYYYY JJ Z
YY-MM-DD HH:MM
PRESS INFO KEY TO DISPLAY THE TROUBLE SHOOTING OF THE ALARMS
System manager
- Machine configuration
- Machine parameters
- System clock programming
- Display regulation
- Service
- Smart card manager
- Change password
- Group manual movements
- Test actuators
- Boiler draining
- Preset configuration data
Alarm history
Enter
+
-
Please Note:
a)
The maximum alarm number the machine can save is 10.
b)
To reset the alarm data memory, carry out “Preset Configuration Data” procedure.
Press the N°7 Enter key to return to the previous environment and/or exit
ALARM DETAILS
ALARM CODE
NO H. MOTOR PULS
10
NO L. MOTOR PULS
11
H. MOTOR ERROR
12
L. MOTOR ERROR
13
FILLING UP T.O.
32
COFFEE HEAT T.O.
33
STEAM HEAT T.O.
34
CHECK FLOW LINE
35
COFFEE TEMPERATURE
37
STEAM TEMPERATURE
38
INFUSION T.O.
41
CORRUPTED DATA
60
CLOCK ERROR
63
MOTOR BLOCK
65
COIN VALIDATOR ERROR
70
CHANGE H2O FILTER
90
GROUP MAINTENA.
91
GRINDER MAINTENA.
93
TOO MUCH COFFEE
15
MAINTENANCE
92