31
english
The display shows
Water Filter
xxxxx
where xxxxx is a selectable value of between 0 ÷ 5000 in steps of 1 litre
If you wish to modify the “water filter” parameter relating to the litres counted, use the
K1gR1
(+) or
K2gR1
(-) keys to increase or decrease the value.
Press the
K5gR1
key (MENU) again to quit the TECHNICAl lEVEl Programming phase.
The display shows
OFF hh:mm
Note:
once you are in the TECHNICAL LEVEL Programming environment, to quit it you will need to scroll
through all the menus by pressing the K5GR1 key (MENU) until you return to the OFF status.
7.6 Alarm signals
bOIlER (FIllING) lEVEl TIME-OUT
When the display shows
Time-Out alarm
Boiler Filling Up
this means that the boiler water level filling time has been exceeded.
Indeed, every time the level probe detects water shortage (probe bare), the filling phase is enabled (EVlIV +
PUMP).
If EVlIV + PUMP remain energised continuously for longer than the time-out set in the TECHNICAl lEVEl
Programming, the dosage of all its main functions is overridden. The keyboards are disabled, and all the ac-
tuators for all operations are overridden.
All the lEDs on the push button panel will start to flash (½ ON, ½ OFF) to signal visually to the user that the
alarm stage has been entered.
GR1
TUTTI I LED SONO LAMPEGGIANTI
GR2
TUTTI I LED SONO LAMPEGGIANTI
GR3
TUTTI I LED SONO LAMPEGGIANTI
To quit the alarm signalling, turn the dosage off and back on again.
All The leDs ARe FlAshing
All The leDs ARe FlAshing
All The leDs ARe FlAshing