23
english
iMPORTAnT: the programming made on the FiRsT UniT is not automatically transferred to all the
other units. To copy the doses onto the other units, press the related continuous keys. This does not
however affect the possibility of programming the remaining units independently from the first via
the operations described in points
,
and
.
If the “prebrewing” function is active (see dedicated paragraphs), the dosage in programming
phase still enables this particular function. therefore wait for it to have ended before stopping the
dispensing in progress.
Note:
During the programming of a unit, the other units remain disabled, along with the tea and steam.
IF A COFFEE DOSE IS NO lONGER ACTIVATED …
Possible troubleshooting:
if, after programming a volumetric dose, the same is no longer dispensed, it is possible that the dosage func-
tion, for some reason, did not receive the pulses from the volumetric meter and thus programmed a dose
amounting to 0 pulses.
Possible causes to verify: volumetric meter incorrectly connected, volumetric meter mixed up with that of
another unit, inoperational water circuit.
PROGRAMMING TEA DOSES
The quantities relating to the tea doses can be modified and stored (by timed control) by following the pro-
cedure below:
In IDlE-ON status, press the
K5gRx
(1..3) key and keep pressing it for 10 seconds; make sure that the
lighting of the lEDs
l5gRx
(1..3) switches from fixed to flashing.
The display shows
Doses setting
Select within30s
Within 30 seconds (time-out to quit the programming phase), press the
K6gRx
key combined with the tea
dose. The lED relating to the
K6gRx
key will flash.
The EVTEA actuator is enabled for the entire duration of tea dose programming.
When the quantity of tea with which the dose is to be programmed is achieved, press the
K6gRx
key used
previously to interrupt product dispensing again, with the consequent de-energising of the EVTEA.
The new time for the tea dose duration is stored.
• To proceed with programming the other tea doses, (if the programming time-out of 30 seconds is not ex-
ceeded and you entered the programming environment from unit 1 by pressing the
K5gR1
key), repeat in
sequence points
and
.
• If the time-out (30 seconds) is triggered during the programming phase, to proceed with its performance,
you will need to repeat the entire sequence described in points
,
and
.
iMPORTAnT: the programming of the tea dose made on the FiRsT UniT is neVeR automatically
transferred to all the other units. To program the tea dose on the remaining units, simply repeat the
operations described in pints
,
and
.
Note:
when programming a Tea dose, the units remain disabled, along with the dispensing of other teas.
PROGRAMMING FOR STEAM TEMPERATURE SIMUlATION
The temperature at which the EVVAP should be deactivated can be modified and stored for simulation by
following the procedure below.