background image

With discharge pump

Section E. 

Cleaning & Maintenance

Gulfstream Plastics Ltd highly recommends the 
following cleaning regimen.  You should always
contact your local governing agency for their 
specific cleaning and disinfecting requirements and
regulations for pedicure spas.  For your clients 
safety, always use the regulations as a minimum 
standard for cleaning and disinfecting.  Combining
your states standards with the regimen listed below
will provide your clients with a safe and healthy
pedicure spa environment experience.

1. Routine maintenance.

Powdered cleansers or

abrasives are NOT RECOMMENDED.  A clean towel
or sponge, are all that are usually needed.  A soft
bristled brush may be used when excessive residue
is present.  Use a mild soap and water solution to
clean the upholstery, but do not over wet.  Wipe
dry with a clean towel. No internal maintenance of
the spa components is necessary.  Remove clean jet
caps and spray with disinfectant after each use.  
For extra protection, our recommendation is that
the system be flushed daily or weekly depending
on use.  To flush the clean jet system fill spa with
hot water to just above the jets.  Add disinfectant.
Run whirlpool for 15 minutes, drain and then wipe
dry with clean soft cloth.

NOTE:  Cleaning or sanitizing is NOT 
disinfecting.  According to the Centers for
Disease Control and Prevention (CDC), and
the US Environmental Protection Agency
(EPA), disinfecting occurs only when there is
a reduction of pathogenic microbes at
99.999%.  Sanitizing is only a reduction of
99.9%.  Cleaning of whirlpool pedicure spas
requires surfactants and chelating 
detergents that are low-foaming and have
the ability to remove body oils, organic oil
additives, mineral oil, skin cells, nail 
clippings etc that can accumulate both in
the basin and the jets which may become 
a fertile area for micro organisms to grow.

The use of oil based products can build up in the
whirlpool system causing clogging in the jets.
Adherence to the above cleaning will minimize
build up.  Gulfstream Plastics Ltd does not 
recommend the use of mineral oil based products.

TESTING/FLUSHING FOOT SPA

After foot spa has been installed, fill tub with water
just above the jets.  Carefully check for leaks at
drain and overflow.  After checking underside for
leaks turn on system by pushing whirlpool button
and watch for leaks as water circulates.  Let tub run
full cycle.  Open drain plug for water discharge.

6

Содержание spas

Страница 1: ...Section A La Rose Component Locations Hand held sprayer Drain control On Off button for CleanJet motor Water fill valve Shiatsu massage back 1 ...

Страница 2: ...rge pump optional ABS piping from drain to discharge Hot cold hoses Clean Jet pump Drain with P Trap Discharge pump 1 2 outlet Outlet switch Hot Cold flex hose 1 2 outlet Top View Sprayhead Switch for discharge pump optional Knob for drain On Off button for jet LED light switch ...

Страница 3: ...nnections The La Rose hot and cold connections are located at the rear of the unit 1 2 Fittings 4 Electrical installation Have a qualified licensed electrician to install the wiring according to local codes The CleanJets are 1 5 hp 120V 15 AMP 60OHZ A GFI protected circuit must be used to supply power to the unit The roller back massage chair uses a 115V supply 5 Secure the base The La Rose base s...

Страница 4: ...the sprayer handle This will turn on the water When you release pressure on the thumb control this will turn the water off 5 Adjustable footrest The La Rose utilizes a comfortable 3 position footrest system in which the footrest can be adjusted by pulling out the pin located at the centre of the La Rose base and placing the pin in one of the tree holes situated on the footrest stand You can also s...

Страница 5: ...t unless they are supervised at all times 3 Use this unit only for its intended use as described in this manual Do not use attachments that are not recommended by the manufacturer 4 Never drop or insert any object into any opening 5 Do not block jets during whirlpool operation 6 The unit must be connected to an electrical supply circuit that is protected by a ground fault circuit interrupter 7 SAV...

Страница 6: ...a with hot water to just above the jets Add disinfectant Run whirlpool for 15 minutes drain and then wipe dry with clean soft cloth NOTE Cleaning or sanitizing is NOT disinfecting According to the Centers for Disease Control and Prevention CDC and the US Environmental Protection Agency EPA disinfecting occurs only when there is a reduction of pathogenic microbes at 99 999 Sanitizing is only a redu...

Страница 7: ... bristled brush or cloth and low foam soap to remove any visible residue Rinse with sprayhead Cold water Remove screen by turning counter clockwise Clean back of screen Jet with same soft brush or cloth Rinse with cold water Replace screen by turning clockwise 7 ...

Страница 8: ...With discharge pump Section F Specifications 8 52 48 29 37 15 ...

Страница 9: ...ble for shipping defective parts back to Gulfstream These parts must be packaged correctly in order to protect against any further damage 4 All parts are to be shipped by UPS Ground Service average 2 5 days 5 All defective parts must be shipped back to Gulfstream withing 30 days of receiving the new replacement parts or warranty will be void 6 Any warranty claim that cannot be determined over the ...