23
EOLO - COMFORT 80
EN
POS. REFERENCE
DESCRIZIONE
6
BUZZER MODE (acoustic
alarm)
Press P3 key and with P1 and P2 keys put in "OFF" or "ON".
7
INITIAL LOAD
At the first ignition of the stove, the auger is completely emty. If necessary have a
preloading pressing P3 key, then P1 for start-up and P4 to stop.
8
STOVE STATE
Displays all parameters connected to stove state: this is the menu for Autorized
Technician.
9
TECHNICA SETTING
Only for Autorized Technician
10
FLAME SETTING
Enables to adjust the flame depending on chimney flue draught.
12.4
IGNITION
We remind you that the first ignition must be executed by authorized and skilled technical personnel who checks
that all is installed in compliance with current regulations and verifies stove's efficiency.
•
If inside the combustion chamber there are booklets, manuals, etc.… please remove them.
•
Check if there are pellets in the hopper.
•
Check that the door is correctly closed.
•
Check that the plug is correctly put into the electric socket.
•
Before starting up the stove, please assure you that the burning pot is clean.
•
To start up the stove, keep pressed P4 key for little while till it appears “START” and then “PREHEATI WAIT"
which starts the preheating of the ignition resistance. After 2 minutes, the display shows “PELLET LOAD, FIRE
WAIT” when the auger load the pellet and the heating of the resistance goes on. When the temperature is
sufficiently high (after about 7-10 minutes), the ignition has occured and the display shows “FLAME PRESENT”.
•
When “FLAME PRESENT” stage has finished, the control unit enters on "WORK” mode and displays the selected
calorific power and room temperature. It is in this stage that P5 and P6 keys adjust the power from 1 to 5. If
room temperature exceeds the limit established during the setting, the calorific power falls at the minimum
displaying “WORK, MODULAT”. When the room temperature returns below the selected temperature, the
stove returns to the set power.
12.5
STOVE ADJUSTMENT
The stove is set in compliance with chimney flue and used pellets data, according to technical characteristics
). If the data do not correspond, the technician can set the stove.
•
If the pellets is small in size and with a greater calorific power, (for example because of encrusted fire pot)
decrease the pellet drop through the menu "FLAME SETTING", press P3 key "PELLET TYPE", press again P3 "PELLET
LOAD" and with P2 key decrease the pellet quantity from -1 (i.e. -2%) to -9 (i.e. -18%).
•
If the chimney flue has a lower draught (for example because of a weak flame or sooty glass) increase the
fume motor revolutions through the menu "FLAME SETTING", press P5 key "CHIMNEY TYPE", press P3 key "FUME-
EXT, CHIMNEY" and with P1 key increase the exhaust fan from +1 (i.e. +5%) to +9 (i.e. +30%).
•
If the chimney flue has a greater draught (for example because of pellet fall from the burning pot) decrease
the exhaust fan revolutions from -1 to -9.
Pay attention to positive and negative values.
12.6
FAILED IGNITION
If the pellets do not burn, the failed ignition will be indicated by the alarm "NO IGNITION"
•
If the room temperature is lower than 10°C, the plug is not able to bear the ignition stage. To support it please
insert some pellets in the burning pot and a piece of burning firelighter igniter material on the pellets (for
example firelighters cubes).
After a failed ignition the burning pot must be empty from the amassed pellets, before
starting up again the stove.
•
Too much pellets in the burning pot, or humid pellets, or sooty burning pot make ignition difficult and create
dense white smoke which is harmful to health and can cause explosions on the combustion chamber. It is
therefore necessary not to stand in front of the stove during ignition stage if dense white smoke is present.