background image

EN

4

2)

 

  This  operating  manual 

is  an  integral  and  essential 

part  of  the  product  and 

must  be  supplied  to  users. 

Users  are  asked  to  read 

the  enclosed  warnings  and 

cautions  carefully,  as  they 

provide  valuable  information 

concerning  safety  during 

installation,  operation  and 

maintenance.    This  manual 

must  be  kept  in  a  safe 

place  and  be  available  for 

consultation  to  new  and 

experienced users alike.

3)

  Ensure  product’s  integrity 

by inspecting the packaging, 

making  sure  it  presents  no 

signs of damage which might 

have  affected  the  enclosed 

machine.

4)

  Check  the  machine’s 

integrity after having carefully 

removed the packaging.

Note: In case of doubt, do not go on 

any further and contact your dealer 

or  retailer  immediately.  They  will 

send  out  specialized  personnel 

authorized  to  perform  service  on 

the espresso machine.

5)

  Packaging  (boxes,  plastic 

bags, foam parts and whatever 

else) must not be left around 

within easy reach of children, 

due to the potential danger it 

represents, nor be discarded 

in the environment.

6)

 Check to see that data on 

the  rating  plate  corresponds 

to those of the main electrical 

supply  which  the  machine 

will be hooked up to.

7)

  The  equipment  must  be 

installed  to  comply  with  the 

applicable  federal,  state  or 

local electrical and plumbing 

codes. 

The 

installation 

also  must  comply  to  the 

manufacturer’s  instructions, 

and  must  be  performed  by 

qualified  and  authorized 

personnel.

8)

 

Incorrect  installation  may 

cause  for  injury/damages  to 

people,  animals  or  objects, 

for  which  the  manufacturer 

shall not be held responsible.

9)

 Safe electrical operation of 

this  device  will  be  achieved 

only when the connection to 

the  power  outlet  has  been 

completed  correctly  and 

in  observance  of  all  local, 

national,  and  international 

electrical  codes  and  safety 

regulations,  and  particularly 

by  grounding  the  unit.  

Make  sure  grounding  has 

been  done  properly  as  it 

represents  a  fundamental 

safety  requirement.    Ensure 

qualified  personnel  check 

Содержание A01808

Страница 1: ...ide precise direct pressure control Motor speed control with La Marzocco s classic paddle interface Absolute and direct control of pressure at any point during the extraction Manuallt operated by the...

Страница 2: ...page 25 page 26 certifications available This additional manual contains information about the one brewing group version For all the other information you need to consult the operating manual of strad...

Страница 3: ...ch of children less than 8 years of age WARNING This machine is for professional use only and should be installed in locations where its use and maintenance is restriced to trained personnel Children...

Страница 4: ...else must not be left around within easy reach of children due to the potential danger it represents nor be discarded in the environment 6 Check to see that data on the rating plate corresponds to th...

Страница 5: ...d not be installed in kitchens 13 Using any electrical device requires that certain fundamental rules be observed In particular do not touch the device with wet or humid hands and feet do not use the...

Страница 6: ...r do not cover the cup warmer tray with cloths or other items 19 The machine s power supply cable must not be replaced by users In case the power supply cable becomes damaged shut off the machine and...

Страница 7: ...th a rated residual operating current not exceeding 30mA is installed 26 This machine is designed only for preparing coffee and hot drinks 27 Any modification to the equipment is prohibited the manufa...

Страница 8: ...220 COLLEGAMENTI VEDERE I PER DETTAGLI ELETTRICI MOD LE SERIE GROUPE V Hz PUISSANCE NOMINALE W ENTR E NOMINALE NOMINALE A PUISSANCE CHAUDI RE CAFE CHAUDI RE VAPEUR PUISSANCE PUISSANCE TOTALE DIMENSION...

Страница 9: ...optimal air circulation WARNING The manufacturer declines any responsibility for any event leading to liability suits whenever grounding has not been completed according to current local national and...

Страница 10: ...less than 30mg l Respecting these values allows the machine to operate at maximum efficiency If these parameters are not present a specific filtration device should be installed while always adhering...

Страница 11: ...sition 1 the steam boiler will then automatically fill to a predetermined level When the correct water level in the steam boiler is reached the machine will automatically stop filling NOTE It may be n...

Страница 12: ...ar NOTE As the steam boiler reaches operating temperature you may hear air and steam escapingfromtheboiler Thisisanormalsound Asthewaterboils airintheboilerisreplacedby steamandexitsthroughthevacuumbr...

Страница 13: ...justment screw and loosen the lock nut 3 Adjust the volumetric pump pressure to the desired measurement looking at the relative pressure gauge 4 Rotate clockwise to increase pressure and counter clock...

Страница 14: ...d residual operating current not exceeding 30mA is installed WARNING The machine must not be dipped in nor splashed with water in order to clean it For cleaning operations please follow the instructio...

Страница 15: ...any leftover grounds 5 Cleaning the body Wipe the stainless steel surfaces with a soft non abrasive cloth in the direction of the glazing marks if any Do not use any alcohol or solvents whatsoever on...

Страница 16: ...n any case after long periods of being idle in order to use the machine to its full potential it is necessary to perform some cleaning cycles before brewing beverages as follows Groups with the portaf...

Страница 17: ...4 Connect to power supply 5 Turn on main power 6 Monitor coffee boiler pressure 7 Adjust the expansion valve 8 Monitor steam boiler pressure 9 Brew espresso 10 Verify working boiler pressures page 18...

Страница 18: ...er Slide the reservoir back into position and replace the drain box Make sure the drain box is inserted fully The water reservoir must make contact with the level indicators on the rear side NOTE The...

Страница 19: ...erted fully The water reservoir must make contact with the level indicators on the rear side If the water tank is empty on the display you will find the following allarm Connect the power cord to a po...

Страница 20: ...t in front of the machine 5 5 WARNING The manufacturer declines any responsibility for any event leading to liability suits whenever grounding has not been completed according to current local nationa...

Страница 21: ...limit the maximum pressure in the coffee boiler to 13 bar Please monitor the coffee boiler pressure gauge during the initial heating process You should notice the gauge approach 13 bar and stop If th...

Страница 22: ...xpansion valve rotate the valve clockwise to raise the pressure and counter clockwise to reduce the pressure It may be necessary to use a spanner to rotate the expansion valve in 1 4 turn or less incr...

Страница 23: ...progress by watching the steam boiler pressure gauge The steam boiler is set at approximately 1 4 Bar of pressure at the factory Once the pressure gauge reaches this point the heating will stop 8 8 C...

Страница 24: ...ilter and activate the brewing process When brewing the coffee boiler pressure should be between 0 13 bar The steam boiler pressure should be set at 1 4 bar but can operate at any setting between 1 3...

Страница 25: ...GE FITTING QUICK CONNECTION 7 L325 150CM S S BRAIDED HOSE G3 8 G1 4 GS3 Item Part number Description 1 914 PLUMBING CONNECTION KIT ETL 2 L308 CLEAR ARMOURED DRAIN HOSE 3 L312 HOSE CLAMP 4 F 8 003 HOSE...

Страница 26: ...rench 27 mm WARNING Hazardous voltage disconnect from power supply before servicing WARNING The coffee group and steam boiler contain water at elevated temperature Water temperature over 125 F 52 C ca...

Страница 27: ...EN 27 4 5 6 7 No 17 No 27...

Страница 28: ...EN 28 8 9 10 No 21 11...

Страница 29: ...EN 29 12 13 14 15 OF F 0 0 0 0 Te c h n i c a l x 10 L a n g u a g e ENGL I SH 14 Clicks Wa t e r t a n k DI SABL ED Turn to select Press to confirm OF F 0 0 0 0 Press until you exit the menu...

Страница 30: ......

Отзывы: