Technical Specifications 

 

 

AC input

 

Voltage and frequency 

Auto ranging 105-264 VAC, 45-65 Hz 

Rated Current 

2.6A @120VAC, 1.4A @240VAC (for 24V 10A output mode) 

Input protection 

AC Fuse (250V, 5A Glass type) 

Inrush limiting 

Inrush current limited NTC 

Efficiency 

Exceeds CEC-400-2012-019-CM requirements 

Power factor 

0.9 

Input Terminals 

Terminal blocks (Push-In Springable type); AWG 24 - AWG 12 

Charger output

 

Nominal voltage rating 

24 volt nominal or field selectable 12/24-volt 

Voltage adjustment 

According to selected number of cells/ Battery type and 

Volt/cell. 

Current 

10A at 24V and 20A at 12V 

Charging characteristic 

ULTRACAP Mode 

Battery Mode 

Line and load 

regulation 

±0.5%  

Output ripple 

<100mV rms 

Temperature 

compensation 

Enable/ Disable, Remote temperature sensing through probe. 

Output protection 

Electronic current limit, Transient protection, 

DC fuse (32V, 20A Blade Fuse- Plug-In type) 

Output Terminals 

Terminal blocks (Lockable type); AWG 24 – AWG 10 

Status 

indication

 

LED status indicator 

AC ON (Green LED), Float (Green LED), Equalize (Yellow LED), 

Fault (Red LED) 

Display  and 

Alarms

 

Display 

LCD Display (16x2) 

LCD Dot Matrix Display 

Displays volts, amps, Mode of operation and Status messages 

Relay Alarm contacts 

Charger Fail, AC Fail, Low DC Voltage, High DC Voltage, 

Summary 

Relay Alarm contact 
ratings 

Rated 2A @ 30 VDC, 0.5A @ 125VAC 
Single form C dry type 

Alarm Terminals 

Spring Cage;  AWG 24 - AWG 16 

Environmental

 

Operating temperature 

-40°C to 65°C (-40°F to 149°F) 

Storage temperature 

-40°C to 85°C (-40°F to 185°F) 

Over temperature 

protection 

Derates over 50C up to 70C 

Above 70C, switches off. 

Humidity 

0% to 95% non-condensing 

Physical

 

Ingress Protection 

IP-20; NEMA-1 

Dimensions 

7.9 x 4.1 x 10.7 in        (W x D x H) 

801 x 105 x 273 mm     (W x D x H) 

Weight 

6.4 lbs (2.9 Kgs) 

 

 
 
 
 
 
 
 
 
 
 

Содержание ULTRA SERIES

Страница 1: ...www lamarchemfg com ULTRA SERIES CHARGER Installation and Operation Manual 106 Bradrock Dr Des Plaines 60018 1967 CPN 134372 Tel 847 299 1188 Fax 847 299 3061 Instruction Drawing Number P25 LUSC 1 Rev...

Страница 2: ...that neither liquids nor any wet material come in contact with any internal components Do not operate this unit outside the input and output ratings listed on the unit nameplate Do not use this unit...

Страница 3: ...or provide a copy of the claim to La Marche may void warranty service for any physical damages reported for repair Returns for Service Save the original shipping container If the product needs to be r...

Страница 4: ...lectrical Connections 6 3 1 Input AC Connections 7 3 2 Output DC Connections 7 3 3 Power Cabling Guide 8 Table 2 Recommended Wire Size table 8 Table 3 Wire Size Area table 8 3 4 Alarm Connections 9 Ta...

Страница 5: ...ndicates that correct AC voltage is present in the Rectifier FLOAT Green Indicates charger is running in floating mode EQ Yellow Indicates charger is running in equalize mode FAULT Red Indicates any f...

Страница 6: ...the front cover to access the Input Output and Alarm connectors See the Figure 3 and Figure 4 in section 3 1 and 3 2 on the next page for reference CAUTION All wiring must be performed by a qualified...

Страница 7: ...recommended wire sizes Note Verify that the connections are tight by tugging on the wires CAUTION When connecting the DC cables to the battery be certain the positive terminal of the charger is connec...

Страница 8: ...20189 Calculating Wire Size Requirements Calculating Current Carrying Capacity of Wire AVD K LF A CMA K LF AVD CMA MaxAmp Note AC wiring terminals can accept wire up to 12 AWG DC wiring terminals can...

Страница 9: ...utput Fuse The Ultra Series charger is equipped with one DC output fuse Refer to unit specifications Section 7 for fuse size information Table 4 Alarm Relay Logic The Ultra series charger is equipped...

Страница 10: ...er This higher current can result in overcharging the Ultracap battery which in turn can result in damage or significantly shorten the life of the Ultracap battery The temperature compensation conside...

Страница 11: ...is equipped with 6 control switches See information below for details on the function of each switch B Float EQ Allows the user to select the mode among Float mode or Equalize mode If charger is opera...

Страница 12: ...IT RESET EXIT performs the back operation from any menu of the system RESET Unit RESET will be initialized when the button is pressed during normal operation not in calibration mode or in alarm state...

Страница 13: ...13 5 3 User Menu Symbols Default Value Press MENU ENTER button to advance to the right and EXIT button to navigate to the left Use UP DOWN buttons to navigate between settings and settings values...

Страница 14: ...Self protect mode It will start automatically after 2 min Over Temperature 1 Check that the unit ventilation is not obstructed e g nothing resting on top of the unit 2 Wait for the charger temperatur...

Страница 15: ...ugh probe Output protection Electronic current limit Transient protection DC fuse 32V 20A Blade Fuse Plug In type Output Terminals Terminal blocks Lockable type AWG 24 AWG 10 Status indication LED sta...

Страница 16: ...16 Document Control and Revision History Part Number 134372 Instruction Number P25 USC 1 Issue ECN 21203 1 21367 02 17 21341 01 17 21203 1 08 16 21203 07 16...

Отзывы: