All La Marche Manufacturing Co. equipment has been thoroughly tested and found to be in proper operating condition upon

shipment from the factory and is warranted to be free from any defect in workmanship and material that may develop within

one year from date of purchase. In addition to the standard one (1) year warranty, La Marche warrants it’s magnetics and

power diodes on a parts replacement basis only for one (1) additional year under normal use.

Any part or parts of the equipment (except fuses, d.c. connectors and other wear-related items) that prove defective within a

one  (1)  year  period  shall  be  replaced  without  charge  providing  such  defect,  in  our  opinion,  is  due  to  faulty  material  or

workmanship and not caused by tampering, abuse, misapplication or improper installation. Magnetics and power diodes are

warranted for two (2) years after date of purchase. During the last one (1) year of this two (2) year warranty period, the

warranty covers parts replacement only, and no labor or other services are provided by La Marche, nor is La Marche obligated

to reimburse the owner or any other person for work performed.

Should a piece of equipment require major component replacement or repair during the first year of the warranty period,

these can be handled in one of two ways:

1. The equipment can be returned to the La Marche factory to have the inspections, parts replacements and testing

performed by factory personnel. Should it be necessary to return a piece of equipment or parts to the factory, the

customer or sales representative must obtain authorization from the factory. If upon inspection at the factory, the

defect was due to faulty material or workmanship, all repairs will be made at no cost to the customer during the

first year. Transportation charges or duties shall be borne by purchaser.

2. If the purchaser elects not to return the equipment to the factory and wishes a factory service representative to

make adjustments  and/or repairs at the  equipment location, La Marche's field service labor rates will apply. A

purchase  order  to  cover  the  labor  and  transportation  cost  is  required  prior  to  the  deployment  of  the  service

representative.

In  accepting  delivery  of  the  equipment,  the  purchaser  assumes  full  responsibility  for  proper  installation,  installation

adjustments and service arrangements. Should minor adjustments be required, the local La Marche sales representative should

be contacted to provide this service only.

All sales are final. Only standard La Marche units will be considered for return. A 25% restocking fee is charged when return

is factory authorized. Special units are not returnable.

In no event shall La Marche Manufacturing Co. have any liability for consequential damages, or loss, damage or expense

directly or indirectly arising from the use of the products, or any inability to use them either separately or in combination with

other equipment or materials, or from any other cause. In addition, any alterations of equipment made by anyone other than

La Marche Manufacturing Co. renders this warranty null and void.

La  Marche  Manufacturing  Co.  reserves  the  right  to  make  revisions  in  current  production  of  equipment,  and  assumes  no

obligation to incorporate these revisions in earlier models.

The  failure  of  La  Marche  Manufacturing  Co.  to  object  to provisions  contained  in  customers'  purchase  orders  or  other

communications shall not be deemed a waiver of the terms or conditions hereof, nor acceptance of such provisions.

The above warranty is exclusive, supersedes and is in lieu of all other warranties, expressed or implied, including any implied

warranty  of  merchantability  or  fitness.  No  person,  agent  or  dealer  is  authorized  to  give  any  warranties  on  behalf  of  the

Manufacturer, nor to assume for the Manufacturer any other liability in connection with any of its products unless made in

writing and signed by an official of the manufacturer.

Содержание MSM 10-12V

Страница 1: ...fg com MSM V 3 Marine High Frequency Battery Charger Installation and Operation Manual 106 Bradrock Dr Des Plaines 60018 1967 Tel 847 299 1188 Fax 847 299 3061 CPN 136069 Instruction Drawing Number P2...

Страница 2: ...hat neither liquids nor any wet material come in contact with any internal components Do not operate this unit outside the input and output ratings listed on the unit nameplate Do not use this unit fo...

Страница 3: ...you have all the necessary parts per your order for proper assembly CAUTION Failure to properly file a claim for shipping damages or provide a copy of the claim to La Marche may void warranty service...

Страница 4: ...1 Controls 7 3 2 2 LED Indicators Alarms 8 3 3 Configure Mode 9 3 3 1 Setting Output Mode 10 3 3 2 Setting Battery Type 10 3 3 3 Setting Float Voltage 10 3 3 4 Setting Equalize Voltage 10 3 3 5 Setti...

Страница 5: ...connections for charging up to three independent battery banks simultaneously The unit is built in a robust non corrosive aluminum enclosure that in conjunction with the drip shield and conformal coat...

Страница 6: ...to the table below Output Voltage Ampere Rating AC Input Voltage AC Input Draw 100 load Case Dimensions W x D x H Weight 12 VDC 10 ADC 120 1 5 201 9 6 X 4 6 X 12 2 5 240 0 8 20 ADC 120 3 1 201 9 6 X...

Страница 7: ...1 Mounting The MSM can be wall mounted using four 10 bolts Install the MSM using appropriate hardware on the wall Figure 1 MSM Mounting Dimensions for Small Case 201 Figure 2 MSM Mounting Dimensions f...

Страница 8: ...loads it is recommended to apply AC power and set the configuration for the correct output see section 3 3 for the configuration instructions Once the configuration is set remove AC power to the charg...

Страница 9: ...r the DC wiring from the wire size Table 2 above If the distance between the charger s DC output and the battery load exceeds 10 feet use the Power Cable Guide in Appendix C to minimize the voltage dr...

Страница 10: ...o the unit is off Disconnect the battery from the charger via the battery disconnect breaker or by manually disconnecting the battery cables Verify that no voltage is present by using a voltmeter at a...

Страница 11: ...Display and Indicators Upon powering up the MSM the LCD will display the unit s software revision and LED s will perform a lamp test After the unit has completed the Start up procedure the AC ON indi...

Страница 12: ...it and the LCD display will read CHARGER FAIL with the following charger conditions Charger is not able to regulate the output voltage AC input is out of range below 95 or above 270VAC LCD will also d...

Страница 13: ...he Up and Down buttons to cycle through the available options and the set button to choose the highlighted option See the chart below for the adjustable settings in the calibration mode The controller...

Страница 14: ...t voltage setting for 24V units is 21 28 2V with a default value of 27 2V Pressing the SET button will store the value in memory and return to the configuration menu 3 3 4 Setting Equalize Voltage Pre...

Страница 15: ...sing the DOWN button will decrement the current limit by 1 The range for the battery current limit is 50 100 The default value is 100 Please consult the battery manufacturer for the maximum charging c...

Страница 16: ...rrent alarm The asterisk on the display indicates the current setting When enabled the Low Current Alarm will be activated when the DC current is below 0 25 Amps The Low Current Alarm shares the same...

Страница 17: ...ld be performed only by trained service personnel or experienced electricians Before setting up any complicated testing give the unit a general inspection Check the following 1 Check DC output cables...

Страница 18: ...ed and recharge it without clearing any protective devices ENVIROMENTAL Audible Noise Less than 65dBA at any point 5 feet from any vertical surface Operating Temperature 4 to 122 F 20 to 50 C Storage...

Страница 19: ...5 0 459 5 390 6 68 9 236 203 11 40 12V 40 6 0 3 2 15 0 612 7 520 8 91 9 314 203 11 60 12V 60 9 2 4 8 15 0 919 1 781 2 137 9 471 205 18 80 12V 80 12 0 6 4 20 0 1225 4 1041 6 183 8 628 205 18 24 Volt Sy...

Страница 20: ...inum Calculating Wire Size Requirements AVD K LF A CMA Calculating Current Carrying Capacity of Wire Table 4 Wire Size Area Table K LF AVD CMA MaxAmp Example If the charger being used has a max ampere...

Страница 21: ...r elects not to return the equipment to the factory and wishes a factory service representative to make adjustments and or repairs at the equipment location La Marche s field service labor rates will...

Страница 22: ...18 Appendix E Document Control and Revision History Part Number 136069 Instruction Number P25 LMSM 3 Issue ECN 21428 21428 4 17 21448 5 17 21478 6 17...