Important Safety Instructions

Before  using  this  equipment  read  all  manuals  and  other  documents  related  to this  unit  and  other  equipment

connected to this unit.  Always have a copy of a units manual on file nearby, in a safe place; if a replacement

copy of a manual is needed it can be found at the www.lamarchemfg.com.

Electrical Safety

WARNING:

Hazardous Voltages are present at the input of power systems.  The output from rectifiers

and from batteries may be low in voltage, but can have a very high current capacity that may cause

severe or even fatal injury.

When working with any live battery or power system, follow these precautions:

Never work alone on any live power system, someone should always be close enough to come to your aid

Remove personal metal items such as rings, bracelets, necklaces, and watches.

Wear complete eye protection (with side shields) and clothing protection.

Always wear gloves and use insulated hand tools.

WARNING:

Lethal Voltages are present within the power system.  Parts inside the unit may still be

energized even when the unit has been disconnected from the AC input power.  Check with a meter

before proceeding. Do not touch any uninsulated parts.

A licensed electrician should be used in the installation of any unit.

Always disconnect the unit from the supply, batteries and loads before performing maintenance or cleaning.

If the unit is hot-swappable, simply remove it from the shelf for any maintenance or cleaning.

Always assume that an electrical connection is live and check the connection relative to ground.

Be sure that neither liquids nor any wet material come in contact with any internal components.

Do not operate this unit outside the input and output ratings listed on the unit nameplate.

Do not use this unit for any purpose not described in the operation manual.

Mechanical Safety

This unit or parts of the unit may get very hot during normal operation, use care when working nearby.

Do not expose equipment to rain or snow.  Always install in a clean, dry location.

Do not operate equipment if it has received a sharp blow, been dropped, or otherwise damaged in any way.

Do not disassemble this unit.  Incorrect re-assembly may result in a risk of electric shock or fire.

Battery Safety

WARNING:

Follow all of the battery manufacturer’s safety recommendations when working with or

around battery systems. DO NOT smoke or introduce a spark or open flame in the vicinity of a battery.

Some batteries generate explosive gases during normal battery operation.

To reduce risk of arc, connect and disconnect the battery only when the unit is off.

If it is necessary to remove the battery connections, always remove the grounded terminal from the battery

first.

Remove personal metal items such as rings, bracelets, necklaces, and watches.

Always wear rubber gloves, safety glasses, and a rubber lined vest/apron when working near a battery.

Have plenty of fresh water and soap nearby in case the battery electrolyte contacts skin, clothing, or eyes.

If the battery electrolyte contacts skin or clothing, wash immediately with soap and water.

If the electrolyte enters the eye, immediately flood the eye with running cold water for at least ten (10) minutes

and seek medical attention immediately.

Do not drop metal on a battery.  A spark or short-circuit could occur and could cause an explosion.

Содержание MSM 10-12V

Страница 1: ...fg com MSM V 3 Marine High Frequency Battery Charger Installation and Operation Manual 106 Bradrock Dr Des Plaines 60018 1967 Tel 847 299 1188 Fax 847 299 3061 CPN 136069 Instruction Drawing Number P2...

Страница 2: ...hat neither liquids nor any wet material come in contact with any internal components Do not operate this unit outside the input and output ratings listed on the unit nameplate Do not use this unit fo...

Страница 3: ...you have all the necessary parts per your order for proper assembly CAUTION Failure to properly file a claim for shipping damages or provide a copy of the claim to La Marche may void warranty service...

Страница 4: ...1 Controls 7 3 2 2 LED Indicators Alarms 8 3 3 Configure Mode 9 3 3 1 Setting Output Mode 10 3 3 2 Setting Battery Type 10 3 3 3 Setting Float Voltage 10 3 3 4 Setting Equalize Voltage 10 3 3 5 Setti...

Страница 5: ...connections for charging up to three independent battery banks simultaneously The unit is built in a robust non corrosive aluminum enclosure that in conjunction with the drip shield and conformal coat...

Страница 6: ...to the table below Output Voltage Ampere Rating AC Input Voltage AC Input Draw 100 load Case Dimensions W x D x H Weight 12 VDC 10 ADC 120 1 5 201 9 6 X 4 6 X 12 2 5 240 0 8 20 ADC 120 3 1 201 9 6 X...

Страница 7: ...1 Mounting The MSM can be wall mounted using four 10 bolts Install the MSM using appropriate hardware on the wall Figure 1 MSM Mounting Dimensions for Small Case 201 Figure 2 MSM Mounting Dimensions f...

Страница 8: ...loads it is recommended to apply AC power and set the configuration for the correct output see section 3 3 for the configuration instructions Once the configuration is set remove AC power to the charg...

Страница 9: ...r the DC wiring from the wire size Table 2 above If the distance between the charger s DC output and the battery load exceeds 10 feet use the Power Cable Guide in Appendix C to minimize the voltage dr...

Страница 10: ...o the unit is off Disconnect the battery from the charger via the battery disconnect breaker or by manually disconnecting the battery cables Verify that no voltage is present by using a voltmeter at a...

Страница 11: ...Display and Indicators Upon powering up the MSM the LCD will display the unit s software revision and LED s will perform a lamp test After the unit has completed the Start up procedure the AC ON indi...

Страница 12: ...it and the LCD display will read CHARGER FAIL with the following charger conditions Charger is not able to regulate the output voltage AC input is out of range below 95 or above 270VAC LCD will also d...

Страница 13: ...he Up and Down buttons to cycle through the available options and the set button to choose the highlighted option See the chart below for the adjustable settings in the calibration mode The controller...

Страница 14: ...t voltage setting for 24V units is 21 28 2V with a default value of 27 2V Pressing the SET button will store the value in memory and return to the configuration menu 3 3 4 Setting Equalize Voltage Pre...

Страница 15: ...sing the DOWN button will decrement the current limit by 1 The range for the battery current limit is 50 100 The default value is 100 Please consult the battery manufacturer for the maximum charging c...

Страница 16: ...rrent alarm The asterisk on the display indicates the current setting When enabled the Low Current Alarm will be activated when the DC current is below 0 25 Amps The Low Current Alarm shares the same...

Страница 17: ...ld be performed only by trained service personnel or experienced electricians Before setting up any complicated testing give the unit a general inspection Check the following 1 Check DC output cables...

Страница 18: ...ed and recharge it without clearing any protective devices ENVIROMENTAL Audible Noise Less than 65dBA at any point 5 feet from any vertical surface Operating Temperature 4 to 122 F 20 to 50 C Storage...

Страница 19: ...5 0 459 5 390 6 68 9 236 203 11 40 12V 40 6 0 3 2 15 0 612 7 520 8 91 9 314 203 11 60 12V 60 9 2 4 8 15 0 919 1 781 2 137 9 471 205 18 80 12V 80 12 0 6 4 20 0 1225 4 1041 6 183 8 628 205 18 24 Volt Sy...

Страница 20: ...inum Calculating Wire Size Requirements AVD K LF A CMA Calculating Current Carrying Capacity of Wire Table 4 Wire Size Area Table K LF AVD CMA MaxAmp Example If the charger being used has a max ampere...

Страница 21: ...r elects not to return the equipment to the factory and wishes a factory service representative to make adjustments and or repairs at the equipment location La Marche s field service labor rates will...

Страница 22: ...18 Appendix E Document Control and Revision History Part Number 136069 Instruction Number P25 LMSM 3 Issue ECN 21428 21428 4 17 21448 5 17 21478 6 17...