La Marche A31 Скачать руководство пользователя страница 20

16 

 

Appendix D

: Manufacturer’s Extended Parts Warranty

 

 (THIS  IS  YOUR  WARRANTY  IF  YOU  HAVE  PURCHASED  THE  EXTENDED  PARTS  WARRANTY  AS  SHOWN  ON  OUR 

INVOICE TO YOU OR IF YOU PURCHASE THE EXTENDED PARTS WARRANTY ANYTIME DURING THE FIRST 12 MONTHS 
AFTER THE DATE OF OUR INVOICE) 

 
All La Marche Manufacturing Co. equipment has been thoroughly tested and found to be in proper operating condition upon shipment 

from the factory. Any part or parts of the equipment (except protective devices, d.c. connectors and other wear-related items) that 
prove defective within a one (1) year period from the date of our invoice to you shall be replaced without charge providing such 

defect, in our opinion, is due to faulty material or workmanship and not caused by tampering, abuse, misapplication or improper 
installation. Labor and parts are covered during this one (1) year period. 

 

For the next four (4) years after the expiration of the one-year warranty, on a parts replacement only basis, any part 

or  parts  of  the  equipment  (except  protective  devices,  d.c.  connectors  and  other  wear-related  items)  that  prove 
defective within the additional four (4) year period shall be replaced providing such defect, in our opinion, is due to 

faulty material or workmanship and not caused by tampering, abuse, misapplication or improper installation. During 
this four (4) year period, the warranty covers parts replacement only, no labor or other services are provided by La 

Marche, nor is La Marche obligated to reimburse the owner or any other person for work performed. If you return the 
equipment to our factory (freight prepaid), we will repair and cover parts and labor.  

 
In addition, magnetics and power diodes are warranted for ten (10) years after the date of our invoice to you. The defect in  the 

magnetics or power diodes must, in our opinion, be due to faulty material or workmanship and not caused by tampering, abuse 
misapplication, or improper installation. Labor and replacement magnetics and power diodes are covered under the extended warranty 

during the initial five (5) year period from the date of our invoice to you. During the next five (5) years of this ten (10) year warranty 
period for magnetics and power diodes, the warranty covers parts replacement only, no labor or other services are provided by La 

Marche, nor is La Marche obligated to reimburse the owner or any other person for work performed. 
 

Should a piece of equipment require major component replacement or repair during the extended warranty period, these can be 
handled in one of three ways: 

1.

 

If  the  Purchaser  elects  to  take  the  responsibility  of  repairing  the  equipment  and  requests  replacement  part(s),  Purchaser  or  Sales 
Representative must contact Factory for return authorization and a purchase order must be issued. Replacement part(s) will be promptly 

shipped and invoiced. After the defective part(s) are returned and inspected at the Factory, if the defect(s) were due to faulty material 

or workmanship, credit will be issued. 

2.

 

The equipment can be returned to the La Marche factory to have the inspections, parts replacements and testing performed by factory 

personnel. Should it be necessary to return a piece of equipment or parts to the factory, the customer or sales representative must 
obtain authorization from the factory. If upon inspection at the factory, the defect was due to faulty material or workmanship, all repairs 

will be made at no cost to the customer under the Extended Warranty. Transportation charges or duties shall be borne by Purchaser. 

3.

 

If the purchaser elects not to return the equipment to the factory and wishes a factory service representative to make adjustments 

and/or  repairs  at  the  equipment  location,  La  Marche's  field  service  labor  rates  will  apply.  A  purchase  order  to  cover  the  labor  and 
transportation cost is required prior to the deployment of the service representative. 

 
In accepting delivery of the equipment, the purchaser assumes full responsibility for proper installation, installation adjustments and 

service arrangements. Should minor adjustments be required, the local La Marche sales representative should be contacted to provide 
this service only. 

 
All sales are final. Only standard La Marche units will be considered for return. A 25% restocking fee is charged when return is factory 

authorized. Special units are not returnable. 
 

In no event shall La Marche Manufacturing Co. have any liability for consequential damages, or loss, damage or expense directly or 
indirectly arising from the use of the products, or any inability to use them either separately or in combination with other equipment 

or materials, or from any other cause. In addition, any alteration of equipment made by anyone other than La Marche Manufacturing 
Co. renders this warranty null and void. 

 
La Marche Manufacturing Co. reserves the right to make revisions in current production of equipment, and assumes no obligation to 

incorporate these revisions in earlier models. 
The failure of La Marche Manufacturing Co. to object to provisions contained in customers' purchase orders or other communications 

shall not be deemed a waiver of the terms or conditions hereof, nor acceptance of such provisions. 

 

THE ABOVE WARRANTY IS EXCLUSIVE, SUPERSEDES AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR 
IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS. NO PERSON, AGENT OR DEALER 

IS  AUTHORIZED  TO  GIVE  ANY  WARRANTIES  ON  BEHALF  OF  THE  MANUFACTURER,  OR  TO  ASSUME  FOR  THE 
MANUFACTURER ANY OTHER LIABILITY IN CONNECTION WITH ANY OF ITS PRODUCTS UNLESS MADE IN WRITING 

AND SIGNED BY AN OFFICIAL OF THE MANUFACTURER. 

 

 

Содержание A31

Страница 1: ...www lamarchemfg com 106 Bradrock Dr Des Plaines IL 60018 1967 CPN 40966 Instruction Drawing Number P25 LA31STD 1 Tel 847 299 1188 Fax 847 299 3061 Revision A08 Rev Date 01 21 ECN 22782 Installation a...

Страница 2: ...ngs listed on the inverter nameplate Do not use this inverter for any purpose not described in the operation manual Mechanical Safety This inverter or parts of the inverter may get very hot during nor...

Страница 3: ...verter sent back for evaluation and repair CAUTION Failure to properly file a claim for shipping damages or provide a copy of the claim to La Marche may void warranty service for any physical damages...

Страница 4: ...1 Rack Mounting the A31 3 2 1 2 Floor Mounting the A31 4 2 2 Making the DC Input Connections 5 2 3 Making the AC Output AC Bypass Line Connections 6 3 0 Operation 6 3 1 A31 Start Up 6 3 2 Checking th...

Страница 5: ...and high voltage conditions the unit is turned off automatically if the DC input is not within the proper range Understanding the Model Number The A31 model number is coded to describe the features t...

Страница 6: ...Installation 2 1 Mounting the A31 When mounting the A31 in any configuration consider the size and weight of the inverter The rack and or floor must be able to support the weight of the inverter as we...

Страница 7: ...ary brackets installed for rear mounting on a relay rack The rack mounting bracket for the 39 enclosure allows for mounting on a 19 or 23 rack and the 9D 9E and 33 enclosures allow for mounting on a 2...

Страница 8: ...olts into the floor Place the inverter on the anchor bolts add appropriate mounting hardware and tighten securely Refer to the figure below for hardware specifications and floor mounting dimensions Al...

Страница 9: ...60 6 10 70 6 8 80 4 8 90 4 8 100 4 8 125 2 6 150 1 6 175 1 0 6 200 2 0 6 250 4 0 4 300 250 MCM 4 Table 4 AC DC Ground Wire Size Minimum Requirements All wires specified in the table are rated at 90 C...

Страница 10: ...164 or 165 also connect the AC bypass line phase hot to the LINE terminal and the AC bypass line neutral to the LINE N terminal Figure 5 One Line Diagram for Typical A31 Inverter Application 3 0 Opera...

Страница 11: ...rees with nameplate For Inverters with 10 15ms Static Switch Option 164 165 1 Push and hold the Pre Charge button until the green READY LED illuminates 2 Release the Pre Charge button and immediately...

Страница 12: ...the specified voltage threshold The LED will turn off once the high DC voltage condition is no longer present Low DC Voltage LV The LV LED will turn on and output from the inverter will be inhibited...

Страница 13: ...nce Although minimal maintenance is required on the A31 inverter routine checks and adjustments are recommended to ensure optimum system performance Yearly 1 Confirm air vents are open Remove dust and...

Страница 14: ...be caused by defective batteries and user loads make sure batteries and loads are free from defects NOTE If the problem is found to be located in the printed circuit boards the board should be replac...

Страница 15: ...ctive Inverter AC Breaker Defective Inverter DC Breaker Broken Wire Shorted or Open C1 Capacitor Low or High DC Voltage Shutdown Activated or Improperly Set Open F2 Fuse Open Fuse on S2A 297 S2A 306 I...

Страница 16: ...sistance between the middle K1 and A2 terminal and a low resistance between terminal A1K2 NOTE A wiring diagram of the module is located on the side of the component IGBT Modules With an ohmmeter meas...

Страница 17: ...Bypass Line Fuse ENVIRONMENTAL Audible Noise Less than 65dBA at any point 5 feet from any vertical surface Operating Temperature 32 to 122 F 0 to 50 C Storage Temperature 40 to 140 F 40 to 60 C Relati...

Страница 18: ...loop feet MaxAmp Maximum allowable amps for given voltage drop AVD Allowable voltage drop K 11 1 for commercial TW copper wire 17 4 for aluminum Calculating Wire Size Requirements AVD K LF A CMA Table...

Страница 19: ...g the first year If the Extended Warranty is purchased the parts required for repair will also be at no cost but La Marche will notify the Purchaser of the costs of Labor to replace the defective part...

Страница 20: ...for return authorization and a purchase order must be issued Replacement part s will be promptly shipped and invoiced After the defective part s are returned and inspected at the Factory if the defect...

Страница 21: ...E Document Control and Revision History Part Number 40966 Instruction Number P25 LA31STD 1 Issue ECN 12266 08 98 22782 01 21 18601 03 10 16816 09 05 16651 01 05 15884 04 03 15349 05 06 02 14575 02 01...