![LA Fitness 15 Neon II Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/la-fitness/15-neon-ii/15-neon-ii_owners-manual_3107238033.webp)
32
“
C
ONSOLE
T
ROUBLE
S
HOOTING
G
UIDE
“
PROBLEM POSSIBLE
CAUSE
SOLUTION
1. Motor Malfunction
Replace Motor
2. Magnetic System
Malfunction or got
stuck
Replace Magnetic System/Flywheel
3. Connection Wires
are not well-connected
or broken
Check whether the wires are well-connected or
replace the broke wires with the new wires
E1
No Motor signal
4. Console Malfunction Replace Console
1. Disconnect the Adaptor or Batteries. Reconnect the Adaptor or Batteries to
REBOOT the system. Wait two minutes then verify that the system works correctly
2. If IC Chips is not well-assembled. Remove and reinsert the IC Chip
E2
The Computer
cannot make contact
with the IC Chip
3. If the above solutions couldn’t solve the problem, replace the IC chip
with a New IC Chip
E3
No heart rate
signal after Body
Fat testing result
when in
Body
Fat Program
(P8)
If you do not place your hands on the
Pulse Sensors
correctly, the
Pulse Sensors
won’t be able pick up the signals. The console would then display an error message
“E3”. To test it again, be sure to place your hands back on the
Pulse Sensors
correctly
1. Check whether the wires
are broken or well-connected
Replace the broken wires with new wires or
re-connected the wires
2. Check whether the motor
is broken (has struggle to
adjust the resistance and will
make an abnormal noise)
Replace Motor
E5
Motor couldn’t
return to the initial
setup value/zero
point
Replace Magnetic System
The Computer is
NOT receiving a
Pulse Signal
Verify that the Hand Pulse Sensor Wire Plugs are connected FIRMLY and correctly
The Hand Pulse Sensors will NOT operate correctly if your skin is extremely dry.
Moisten your hands with a little water and try again.
Grasp the Hand Pulse Sensors firmly and avoid moving your hands while exercising.
The computer will need a few seconds to detect and display your correct pulse rate. If
this does not work, try relaxing your grip on the Hand Pulse Sensors
Clean the Hand Pulse Sensors to ensure a good contact between your body and the
Pulse Sensors
No Hand
Pulse
Signal or
incorrect
Hand Pulse
Signal
The Computer is
receiving a faint or
intermittent Pulse
Signal
The problem still exists, replace the Hand Pulse Sensors.
The Adaptor is not
plugged in (item
power supply from
Adaptor)
Check that the Adaptor is correctly connected to an electrical outlet and plugged into
the socket on the machine correctly
The LCD
Screen does
not display
anything
The Computer is
faulty
Replace the Computer
Содержание 15 Neon II
Страница 37: ...36 FRONT B A C K...