background image

 

 

  Key (DIRECTION key) 

 

Project the image direction (can display 4 different orientations) 

 Back-light 

on

 

 

DISPLAY key

 

 

Toggle between the time and outdoor temperature or automatic alternates time/outdoor temperature 
every 5 seconds display mode for projection 

 Back-light 

on 

 

ALARM 1 key

 

 

Enter/exit the alarm 1 setting mode 

 

Active/de-active the alarm time 1 (even inside snooze mode) 

 

Stop the alarm during alarm ringing 

 Back-light 

on 

 

HOUR/IN key 

 

Press to set the alarm hour (inside alarm setting mode) 

 

Press shortly to toggle between MIN/MAX and current indoor temperature and humidity data 

 

Press and hold for 4 seconds to reset the MIN/MAX indoor temperature and humidity data 

 

Stop the alarm during alarm ringing 

 

Stop snooze mode 

 Back-light 

on 

 

MIN/OUT key  

 

Press shortly to toggle between MIN/MAX and current temperature/humidity values for selected 
outdoor temperature channel. 

 

Press and hold for 4 seconds to reset the MIN/MAX records for selected channel. 

 

Press to set the alarm minute (inside alarm setting mode) 

 

Stop the alarm during alarm ringing 

 

Stop snooze mode 

 Back-light 

on 

 

ALARM 2 key

 

 

Enter/exit the alarm 2 setting mode 

 

Active/de-active the alarm time 2 (even inside snooze mode) 

 

Stop the alarm during alarm ringing

 

 Back-light 

on

 

 

SNOOZE key  

 Active/de-active 

snooze 

function

 

 

Active the projection in battery operated mode

 

 

Press and hold 2 seconds to stop the alarm during alarm ringing

 

 

Exit the setting modes

 

 Back-light 

on

 

Содержание WS-9520U

Страница 1: ...calendar moon phase indoor and outdoor temperature indoor and outdoor relative humidity this unit will never keep you guessing on current and future weather conditions Operation of this product is sim...

Страница 2: ...n orientation possible LCD contrast selectable E L back light Low battery indicator Table standing AC DC power adapter included The Remote Temperature Humidity Sensor Remote transmission of outdoor te...

Страница 3: ...data is displayed proceed to step 2 2 Within 4 minutes of activating the weather projection station place the batteries into the remote temperature humidity sensor see To install and replace batterie...

Страница 4: ...ries and wait for at least 3 minutes before reinserting them 2 Within 4 minutes of activating the weather projection station place the batteries into the remote temperature humidity sensor see To inst...

Страница 5: ...humidity sensor need to be reset when one of the following conditions occur Unsuccessful 433MHz signal reception Malfunction of the units Batteries need replacement For resetting remove all batteries...

Страница 6: ...me announced at the top of the minute in Coordinated Universal Time which is also known as Greenwich Mean Time GMT This time does not follow Daylight Saving Time changes After the top of the minute a...

Страница 7: ...on HOUR IN key Press to set the alarm hour inside alarm setting mode Press shortly to toggle between MIN MAX and current indoor temperature and humidity data Press and hold for 4 seconds to reset the...

Страница 8: ...er identification number Outdoor relative humidity in RH WWVB Signal Reception Icon LCD SCREEN The LCD screen is split into 5 sections displaying the information for time date weather forecast indoor...

Страница 9: ...be adjusted according to Daylight Saving Time in the spring and fall For areas that do not recognize DST changes Arizona and parts of Indiana turn the DST OFF 1 The digit ON will start flashing on th...

Страница 10: ...set time into the received time During reception attempts the WWVB tower icon will flash If reception has been unsuccessful then the WWVB tower icon will not appear but reception will still be attempt...

Страница 11: ...ations with rapid changes of weather conditions the weather icons can be set to a different level for faster display of weather conditions 1 The current sensitivity value will start flashing 2 Use the...

Страница 12: ...in the air pressure the weather icons will update accordingly to represent the change in weather If the icons do not change then it means either the air pressure has not changed or the change has bee...

Страница 13: ...te Once the weather tendency indicator has registered a change in air pressure it will remain permanently visualized on the LCD WEATHER BOY FORECASTING ICONS A total of 24 Weather Boy icons combinatio...

Страница 14: ...3 Three times to return to transmitter 1 Note The transmitter number will only be displayed if there is more than one transmitter being used 3 To reset the MIN MAX outdoor temperature and the time at...

Страница 15: ...ment and interference levels If no reception is possible despite the observation of these factors all system units have to be reset see Setting up above POSITIONING THE REMOTE TEMPERATURE HUMIDITY SEN...

Страница 16: ...0 2 x 169 6 x 74 4 mm Remote temperature humidity sensor 6 29 x 1 69 x 0 90 inches 160 x 43 x 23 mm LIABILITY DISCLAIMER The manufacturer and supplier cannot accept any responsibility for any incorrec...

Страница 17: ...warranty covers only actual defects within the product itself and does not cover the cost of installation or removal from a fixed installation normal set up or adjustments claims based on misrepresen...

Страница 18: ...ICE COMPLIES WITH PART 15 OF THE FCC RULES OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS 1 THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND 2 THIS DEVICE MUST ACCEPT INTERFERENCE RECEIVED INC...

Отзывы: