background image

 

14 

 

 
 
 
 
 
 
 
 

 

 

TOGGLING AND RESETTING THE OUTDOOR RECORDINGS: 

1. 

To toggle between the outdoor current, MIN/MAX temperature and humidity data and the times  (for 
temperature data only) that were recorded press the MIN/OUT key: 
Once to show the MAX outdoor temperature and humidity data with the recorded time and date.  
Twice to show the MIN outdoor temperature and humidity data with the recorded time and date.  
Three times to return to the current displayed values.  

2. 

To toggle between transmitters, press the CH/+ key: 
Once to show transmitter 2 
Twice to show transmitter 3 
Three times to return to transmitter 1 

Note:  The transmitter number will only be displayed if there is more than one transmitter being 

used

3. 

To reset the MIN/MAX outdoor temperature, and the time at which they were recorded, press and 
hold the MIN/OUT key for about 4 seconds. This will reset all MIN/MAX data recorded to the 
displayed values for that particular transmitter.  

 

TO EXIT THE MANUAL SETTING MODE 

To exit the manual setting mode anytime during the manual setting modes, press the SNOOZE key anytime 
or wait for automatic timeout. The mode will return to normal time display. 

 

E.L. BACK-LIGHT 

The back-light is automatically switched ON when any keys are pressed. The back-light will be switched on 
for approximately 10 seconds before automatically switching OFF. However, if the SNOOZE key is pressed 
and held down, then back-light will remain ON constantly until the key is released.

 

 

ABOUT THE OUTDOOR REMOTE TEMPERATURE/HUMIDITY SENSOR 

The range of the remote temperature/humidity sensor may be affected by the temperature. At cold 
temperatures the transmitting distance may be decreased. Please bear this in mind when positioning the 
sensor. The battery life may be reduced as well at cold temperatures. 

 

CHECKING FOR 433MHz RECEPTION 

If the outdoor temperature and humidity data is not being received within three minutes after setting up 
(the display shows “- -. - °F” and “- -%” on the outdoor section of the weather projection station after 3 
attempts during normal operation), please check the following items: 
1. 

The distance of the weather projection station or remote temperature/humidity sensor should be at 
least 6 feet (2 meters) away from any interfering sources such as computer monitors or TV sets. 

2. 

Avoid placing the remote temperature/humidity sensor onto or in the immediate proximity of metal 
window frames. 

3. 

Using other electrical products such as headphones or speakers operating on the 433MHz-signal 
frequency may prevent correct signal transmission or reception. Neighbors using electrical devices 
operating on the 433MHz-signal frequency can also cause interference. 

 

Outdoor 
temperature 
in °F/ °C 

Outdoor relative 
humidity in RH%

Transmitter 
identification number 
(only if there is more 
than one transmitter) 

Outdoor reception 
indicator 

Содержание WS-9520U

Страница 1: ...calendar moon phase indoor and outdoor temperature indoor and outdoor relative humidity this unit will never keep you guessing on current and future weather conditions Operation of this product is sim...

Страница 2: ...n orientation possible LCD contrast selectable E L back light Low battery indicator Table standing AC DC power adapter included The Remote Temperature Humidity Sensor Remote transmission of outdoor te...

Страница 3: ...data is displayed proceed to step 2 2 Within 4 minutes of activating the weather projection station place the batteries into the remote temperature humidity sensor see To install and replace batterie...

Страница 4: ...ries and wait for at least 3 minutes before reinserting them 2 Within 4 minutes of activating the weather projection station place the batteries into the remote temperature humidity sensor see To inst...

Страница 5: ...humidity sensor need to be reset when one of the following conditions occur Unsuccessful 433MHz signal reception Malfunction of the units Batteries need replacement For resetting remove all batteries...

Страница 6: ...me announced at the top of the minute in Coordinated Universal Time which is also known as Greenwich Mean Time GMT This time does not follow Daylight Saving Time changes After the top of the minute a...

Страница 7: ...on HOUR IN key Press to set the alarm hour inside alarm setting mode Press shortly to toggle between MIN MAX and current indoor temperature and humidity data Press and hold for 4 seconds to reset the...

Страница 8: ...er identification number Outdoor relative humidity in RH WWVB Signal Reception Icon LCD SCREEN The LCD screen is split into 5 sections displaying the information for time date weather forecast indoor...

Страница 9: ...be adjusted according to Daylight Saving Time in the spring and fall For areas that do not recognize DST changes Arizona and parts of Indiana turn the DST OFF 1 The digit ON will start flashing on th...

Страница 10: ...set time into the received time During reception attempts the WWVB tower icon will flash If reception has been unsuccessful then the WWVB tower icon will not appear but reception will still be attempt...

Страница 11: ...ations with rapid changes of weather conditions the weather icons can be set to a different level for faster display of weather conditions 1 The current sensitivity value will start flashing 2 Use the...

Страница 12: ...in the air pressure the weather icons will update accordingly to represent the change in weather If the icons do not change then it means either the air pressure has not changed or the change has bee...

Страница 13: ...te Once the weather tendency indicator has registered a change in air pressure it will remain permanently visualized on the LCD WEATHER BOY FORECASTING ICONS A total of 24 Weather Boy icons combinatio...

Страница 14: ...3 Three times to return to transmitter 1 Note The transmitter number will only be displayed if there is more than one transmitter being used 3 To reset the MIN MAX outdoor temperature and the time at...

Страница 15: ...ment and interference levels If no reception is possible despite the observation of these factors all system units have to be reset see Setting up above POSITIONING THE REMOTE TEMPERATURE HUMIDITY SEN...

Страница 16: ...0 2 x 169 6 x 74 4 mm Remote temperature humidity sensor 6 29 x 1 69 x 0 90 inches 160 x 43 x 23 mm LIABILITY DISCLAIMER The manufacturer and supplier cannot accept any responsibility for any incorrec...

Страница 17: ...warranty covers only actual defects within the product itself and does not cover the cost of installation or removal from a fixed installation normal set up or adjustments claims based on misrepresen...

Страница 18: ...ICE COMPLIES WITH PART 15 OF THE FCC RULES OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS 1 THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND 2 THIS DEVICE MUST ACCEPT INTERFERENCE RECEIVED INC...

Отзывы: