Note:

  Before permanently mounting ensure that the indoor weather station is able to receive WWVB signals from the 

desired location.  Also, extreme and sudden changes in temperature will decrease the accuracy of the indoor weather station, 
and changes in elevation will result with inaccurate weather forecasting for the next 12 to 24 hours.  These changes will 
require a 12 to 24 hour wait before obtaining reliable data. To achieve a true temperature reading, avoid mounting where 
direct sunlight can reach the remote temperature/humidity sensor or indoor weather station. While the remote 
temperature/humidity sensor is weather proof, avoid submersion in water or snow. We recommend that you mount the 
remote temperature/humidity sensor on an outside North-facing wall.  The sending range is 80ft—obstacles such as walls, 
concrete, and large metal objects can reduce the range.  Place both units in their desired location, and wait approximately 15 
minutes before permanently mounting to ensure that there is proper reception.  The indoor weather station should display a 
temperature and humidity in the OUTDOOR LCD and wind speed (can be 0.0) in the WIND SPEED LCD within 4 minutes 
of setting up.   

 

I. 

THE REMOTE TEMPERATURE/HUMIDITY SENSOR 

 

The remote temperature/humidity sensor can be mounted in several ways: 

• 

With the use of screws 

• 

Using adhesive tape 

• 

Using nylon straps 

 

A. 

B. 

C. 

MOUNTING WITH SCREWS 

 

1) 

Remove the mounting bracket from the remote 
temperature/humidity sensor. 

2)  Place the mounting bracket over the desired location. 
3) Through the two screw holes of the bracket, mark the 

mounting surface with a pencil. 

4)  Screw mounting bracket onto the mounting surface.  Ensure 

that the screws are tight against the bracket. 

5) Insert the remote temperature/humidity sensor into the 

bracket. 

 

MOUNTING WITH ADHESIVE TAPE 

 

1)  With a nonabrasive solution, clean and dry the back of the mounting bracket and the mounting surface 

to ensure a secure hold.  The mounting surface should be smooth and flat. 

2)  Remove the protective strip from one side of the tape. 
3)  Adhere the tape to the designated area on the back of the mounting bracket. 
4)  Remove the protective strip from the other side of the tape. 
5)  Position the remote temperature/humidity sensor in the desired location, ensuring that the indoor 

weather station can receive the signal. 

 

MOUNTING WITH NYLON STRAPS

 

 

1) 

Remove the mounting bracket from the remote 
temperature/humidity sensor. 

2)  Place two nylon straps through the slots on the mounting bracket. 
3)  Place the remote temperature/humidity sensor in your desired 

mounting location. 

4)  Fasten the two nylon straps securely around the mounting 

location. 

 

 
 
 
 
 
 
 
 
 

 

17

Содержание WS-7395U

Страница 1: ...WS 7395U Wireless 433 MHz Radio controlled Weather Station Instruction Manual...

Страница 2: ...ting the Time 8 Setting the Year Day and Month 9 Setting the Snooze 9 Setting the Temperature Format 9 Setting the Forecast Sensitivity 10 Features Weather Forecast Icons and Tendency Arrows 11 Indoor...

Страница 3: ...cy Division WWVB radio station is located in Ft Collins Colorado and transmits the exact time and date signal continuously throughout the United States at 60 kHz The signal can be received up to 2 000...

Страница 4: ...nsors and source of transmission for all remote sensor data The remote temperature humidity sensor should be placed in a dry shaded area Fog and mist will not harm your remote temperature humidity sen...

Страница 5: ...TATION 1 Remove the battery cover To do this insert a solid object in the space provided at the lower central position of the battery cover then push up and pull out on the battery cover 2 Observe the...

Страница 6: ...t setting I PROGRAMMING SEQUENCE AND DEFAULT SETTINGS The programming sequence and default factory settings are as follows LCD Contrast 5 Time Zone 5 Eastern Daylight Saving Time ON Radio controlled t...

Страница 7: ...LCD and the number setting will flash 3 Press and release the SET button twice 4 DST will appear in the DATE LCD and either ON or OFF will flash in the TIME LCD 5 Press and release the ALM button to s...

Страница 8: ...ch every night between these hours and overrides any manually set time The WWVB tower icon appearing in the TIME LCD will flash when a signal search is in progress and a signal is being received and w...

Страница 9: ...ET button to confirm and advance to the snooze setting X SETTING THE SNOOZE 1 Press and hold the SET button for 5 seconds 2 LCD will show in the TIME LCD and the number setting will flash 3 Press and...

Страница 10: ...ess and hold the SET button for 5 seconds 2 LCD will show in the TIME LCD and the number setting will flash 3 Press and release the SET button twelve times 4 Either 1 2 or 3 will flash in the TIME LCD...

Страница 11: ...nge to occur quickly If the symbols do not change then the weather has not changed or the change has been slow and gradual B WEATHER TENDENCY ARROWS Other possible displays in the FORECAST LCD are 2 w...

Страница 12: ...in once while MAX is still displayed twice otherwise MIN appears to the right of the outdoor temperature indicating that the minimum temperature and the time and date of occurrence are displayed 3 Whi...

Страница 13: ...he display will automatically go back to the normal display mode showing the current dew point reading To reset the maximum or minimum dew point record While viewing either the maximum or minimum dew...

Страница 14: ...l To reset the maximum and minimum wind wind chill values 1 Select the value you wish to reset by pressing and releasing the WIND SNZ button 2 Press and hold the SET button for 5 seconds 3 The record...

Страница 15: ...aper Small waves develop becoming longer whitecaps 5 19 24 mph 29 38 kph 17 21 knots Fresh Breeze Small trees sway White crested wavelets whitecaps form some spray 6 25 31 mph 39 49 kph 22 27 knots St...

Страница 16: ...egin to flash in the DATE LCD 3 Press and release the IN HR button to adjust the hour Note When in the 12 hour mode and setting an alarm for a time between noon and midnight PM will appear to the left...

Страница 17: ...ITY SENSOR The remote temperature humidity sensor can be mounted in several ways With the use of screws Using adhesive tape Using nylon straps A B C MOUNTING WITH SCREWS 1 Remove the mounting bracket...

Страница 18: ...making sure to lock it in place MOUNTING WITH NYLON STRAPS 1 Unlock the mounting bracket from the remote wind speed sensor leaving the wire going through the bracket 2 Place two nylon straps through t...

Страница 19: ...lem Temperatures do not match if units are placed next to each other Solution Each temperature humidity sensor is manufactured to be accurate to within 2 degree plus or minus and under normal conditio...

Страница 20: ...re checking interval Every 15 seconds Indoor humidity checking interval Every 20 seconds Outdoor temperature checking interval remote temperature humidity sensor Every 128 seconds Outdoor humidity che...

Страница 21: ...ental damages therefore the above exclusion of limitation may not apply to you For warranty work technical support or information contact La Crosse Technology 700 East Main Street Spring Grove MN 5597...

Страница 22: ...22 All trademarks and patents are acknowledged...

Отзывы: