background image

 
 
 
WARRANTY INFORMATION 
 

La Crosse Technology provides a 1-year warranty on this weather station.  Contact La Crosse Technology immediately upon 
discovery of any defects covered by this warranty. 
 
Before sending the Weather Station in for repairs, contact La Crosse Technology.  The Weather Station will be repaired or replaced 
with the same or similar model. 
 
This warranty does not cover any defects resulting from improper use, unauthorized repairs, faulty batteries, or the Weather Stations 
inability to receive a signal due to any source of interference. 
 
LA CROSSE TECHNOLOGY WILL NOT ASSUME LIABILITY FOR INCIDENTAL, CONSEQUENTIAL, PUNITIVE, OR 
OTHER SIMILAR DAMAGES ASSOCIATED WITH THE OPERATION OR MALFUNCTION OF THIS WEATHER STATION.  
THIS PRODUCT IS NOT TO BE USED FOR MEDICAL PURPOSES OR FOR PUBLIC INFORMATION.  THIS PRODUCT IS 
NOT A TOY.  KEEP OUT OF CHILDRE’S REACH. 
 
This warranty gives you specific legal rights.  You may also have other rights specific to your State.  Some States do no allow the 
exclusion of consequential or incidental damages therefore the above exclusion of limitation may not apply to you. 
 
For warranty work, technical support, or information contact 
 

La Crosse Technology 

700 East Main Street 

Spring Grove, MN 55974 

Phone: 507.895.7095 

Fax: 507.895.8000 

 

e-mail: 

[email protected]

 

(warranty work) 

[email protected]

 

(information on other products) 

web: 

www.lacrossetechnology.com

 

 
 
 

FCC DISCLAIMER 

 
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO 
CONDITIONS: 
 
1. THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND 
2. THIS DEVICE MUST ACCEPT INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE 

UNDESIRED OPERATION. 

 
FCC ID: OMO-01RX (Receiver), OMO-01TX (transmitter) 
 

Freq. 433.92 MHz 

La Crosse Technology 

Made in China 

WS-7395U 

 
 
081703 
All rights reserved.  This handbook must not be reproduced in any form, even in excerpts, or duplicated or processed using electronic, 
mechanical or chemical procedures without written permission of the publisher. 
This handbook may contain mistakes and printing errors.  The information in this handbook is regularly checked and corrections 
made in the next issue.  We accept no liability for technical mistakes or printing errors, or their consequences. 

 

21

Содержание WS-7395U

Страница 1: ...WS 7395U Wireless 433 MHz Radio controlled Weather Station Instruction Manual...

Страница 2: ...ting the Time 8 Setting the Year Day and Month 9 Setting the Snooze 9 Setting the Temperature Format 9 Setting the Forecast Sensitivity 10 Features Weather Forecast Icons and Tendency Arrows 11 Indoor...

Страница 3: ...cy Division WWVB radio station is located in Ft Collins Colorado and transmits the exact time and date signal continuously throughout the United States at 60 kHz The signal can be received up to 2 000...

Страница 4: ...nsors and source of transmission for all remote sensor data The remote temperature humidity sensor should be placed in a dry shaded area Fog and mist will not harm your remote temperature humidity sen...

Страница 5: ...TATION 1 Remove the battery cover To do this insert a solid object in the space provided at the lower central position of the battery cover then push up and pull out on the battery cover 2 Observe the...

Страница 6: ...t setting I PROGRAMMING SEQUENCE AND DEFAULT SETTINGS The programming sequence and default factory settings are as follows LCD Contrast 5 Time Zone 5 Eastern Daylight Saving Time ON Radio controlled t...

Страница 7: ...LCD and the number setting will flash 3 Press and release the SET button twice 4 DST will appear in the DATE LCD and either ON or OFF will flash in the TIME LCD 5 Press and release the ALM button to s...

Страница 8: ...ch every night between these hours and overrides any manually set time The WWVB tower icon appearing in the TIME LCD will flash when a signal search is in progress and a signal is being received and w...

Страница 9: ...ET button to confirm and advance to the snooze setting X SETTING THE SNOOZE 1 Press and hold the SET button for 5 seconds 2 LCD will show in the TIME LCD and the number setting will flash 3 Press and...

Страница 10: ...ess and hold the SET button for 5 seconds 2 LCD will show in the TIME LCD and the number setting will flash 3 Press and release the SET button twelve times 4 Either 1 2 or 3 will flash in the TIME LCD...

Страница 11: ...nge to occur quickly If the symbols do not change then the weather has not changed or the change has been slow and gradual B WEATHER TENDENCY ARROWS Other possible displays in the FORECAST LCD are 2 w...

Страница 12: ...in once while MAX is still displayed twice otherwise MIN appears to the right of the outdoor temperature indicating that the minimum temperature and the time and date of occurrence are displayed 3 Whi...

Страница 13: ...he display will automatically go back to the normal display mode showing the current dew point reading To reset the maximum or minimum dew point record While viewing either the maximum or minimum dew...

Страница 14: ...l To reset the maximum and minimum wind wind chill values 1 Select the value you wish to reset by pressing and releasing the WIND SNZ button 2 Press and hold the SET button for 5 seconds 3 The record...

Страница 15: ...aper Small waves develop becoming longer whitecaps 5 19 24 mph 29 38 kph 17 21 knots Fresh Breeze Small trees sway White crested wavelets whitecaps form some spray 6 25 31 mph 39 49 kph 22 27 knots St...

Страница 16: ...egin to flash in the DATE LCD 3 Press and release the IN HR button to adjust the hour Note When in the 12 hour mode and setting an alarm for a time between noon and midnight PM will appear to the left...

Страница 17: ...ITY SENSOR The remote temperature humidity sensor can be mounted in several ways With the use of screws Using adhesive tape Using nylon straps A B C MOUNTING WITH SCREWS 1 Remove the mounting bracket...

Страница 18: ...making sure to lock it in place MOUNTING WITH NYLON STRAPS 1 Unlock the mounting bracket from the remote wind speed sensor leaving the wire going through the bracket 2 Place two nylon straps through t...

Страница 19: ...lem Temperatures do not match if units are placed next to each other Solution Each temperature humidity sensor is manufactured to be accurate to within 2 degree plus or minus and under normal conditio...

Страница 20: ...re checking interval Every 15 seconds Indoor humidity checking interval Every 20 seconds Outdoor temperature checking interval remote temperature humidity sensor Every 128 seconds Outdoor humidity che...

Страница 21: ...ental damages therefore the above exclusion of limitation may not apply to you For warranty work technical support or information contact La Crosse Technology 700 East Main Street Spring Grove MN 5597...

Страница 22: ...22 All trademarks and patents are acknowledged...

Отзывы: