background image

 

6

Program Mode 

 
Programming Note:
 If 30 seconds are allowed to pass or either the IN or 
the OUT button is pressed during programming modes, the unit will set the 
last information entered—the display will stop flashing and return to 
normal time-date readings 

 

A.  Function Keys 

 

There are four function buttons on the 
WS-7049U. The two buttons on the 
front are labeled 

“MIN/MAX/RESET”

 

and 

“CH”

.  The two buttons on the 

back are labeled 

“SET”

 and 

“+”

 

B.

 

Time Setting 

 

1.

 

Press and hold the 

“SET”

 button for 3 seconds 

2.

 

The hour digit will flash. 

3.

 

Press and release the 

“+”

 button to change the hour.  Press 

the 

“+”

 button once and the hour will increase by one, twice 

and the hour will increase by two, etc.   

4.

 

Press and release the 

“SET” 

button to confirm the hour 

setting and to advance to the minute setting mode. 

5.

 

The minute digits should be flashing. 

6.

 

Press and release the 

"+”

 button to change the minutes—

increasing the minutes by increments of 1 with each press of 
the 

“+”

 button. 

7.

 

Press and release the 

“SET”

 button to confirm the minutes 

and complete the time setting. 

 
 
 
 
 
 
 
 
 

Содержание WS-7049U

Страница 1: ...WS 7049U Wireless 433 MHz Weather Station with Forecast Instruction Manual...

Страница 2: ...m Mode Function Keys 6 Time Setting 6 Features Weather Forecast 7 8 Indoor Temperature and Humidity 9 Outdoor Temperatures 9 Minimum Maximum Records Indoor Outdoor Resetting 9 Additional Remote Temper...

Страница 3: ...rews 4 One strip double sided adhesive tape 5 Instruction manual and warranty card ADDITIONAL EQUIPMENT not included 1 Two fresh AA 1 5V batteries for indoor weather station 2 Two fresh AA 1 5V batter...

Страница 4: ...s you can place your remote temperature sensor outdoors and set your time The remote temperature sensor should be placed in a dry shaded area The remote temperature sensor has a range of 80 feet Any w...

Страница 5: ...o this insert a solid object in the space provided at the lower central position of the battery cover then push up and pull out on the battery cover 2 Observe the correct polarity and install 2 AA bat...

Страница 6: ...labeled SET and B Time Setting 1 Press and hold the SET button for 3 seconds 2 The hour digit will flash 3 Press and release the button to change the hour Press the button once and the hour will incr...

Страница 7: ...e readings to provide an accurate forecast creating a necessity to disregard all weather forecasting for 12 24 hours after the unit has been set up reset or moved from one altitude to another i e from...

Страница 8: ...It will not change from sunny directly to rainy although it is possible for the change to occur quickly If the symbols do not change then the weather has not changed or the change has been slow and g...

Страница 9: ...rature Sensors IV Minimum and Maximum Temperature Records The WS 7049U keeps a record of the MINIMUM and MAXIMUM temperature for both the indoor and outdoor modes A Viewing Minimum and Maximum Tempera...

Страница 10: ...ture on its LCD and the TX3UP will monitor the temperature via a probe for measuring soil or water temperatures Note When setting up multiple units it is important to remove the batteries from all exi...

Страница 11: ...the MIN MAX RESET button 3 The maximum recorded temperature will be displayed 4 Press and release the MIN MAX RESET button while MIN is still displayed otherwise press the button twice 5 The minimum r...

Страница 12: ...units in their desired location and wait approximately 10 minutes before permanently mounting to ensure that there is proper reception The indoor weather station should display a temperature in the O...

Страница 13: ...he indoor temperature station can receive the signal II THE INDOOR TEMPERATURE STATION The indoor temperature station can be mounted in two ways with the table stand or on the wall with the use of a w...

Страница 14: ...sensor is manufactured to be accurate to within 1 degree plus or minus and under normal conditions so two sensors could be as much as 2 degrees different However the difference can be exaggerated fur...

Страница 15: ...displays and units with a soft damp cloth Do not use solvents or scouring agents They may mark the displays and casings Do not submerge in water Immediately remove all low powered batteries to avoid l...

Страница 16: ...ng interval Every 10 seconds Indoor humidity checking interval Every 1 minute Outdoor temperature checking interval Remote Temperature Sensor Every 1 minute Outdoor temperature reception Indoor Weathe...

Страница 17: ...d for the repairs or examination The owner must pay any shipping charges incurred in getting your La Crosse Technology Ltd product to a La Crosse Technology Ltd authorized service center La Crosse Tec...

Страница 18: ...complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received includ...

Отзывы: