INSTALLATION AND 

USER’S MANUAL 

 

 

External and internal  

temperature recorders

 

 

 

 
 
 
 

DataCOLD 500 T/R 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

   

Carrier Transicold Europe – 10, Bd de l’Oise – 95031 Cergy Pontoise Cédex – France

                                                                       Carrier Transicold North America, 700 Olympic Drive, Athens, Ga. 30601 - U.S.A.

 Carrier Refrigeration Operation 2003   Printed in France 02-03 / 62-61138-20

 

Содержание DATACOLD 500 T/R

Страница 1: ...perature recorders DataCOLD 500 T R Carrier Transicold Europe 10 Bd de l Oise 95031 Cergy Pontoise Cédex France Carrier Transicold North America 700 Olympic Drive Athens Ga 30601 U S A Carrier Refrigeration Operation 2003 Printed in France 02 03 62 61138 20 ...

Страница 2: ...he R Version is suitable for in cab installation and the T Version for outside mounting on a trailer Both versions are available with or without integrated printer A printer can be retrofitted at any time the recorder has been designed already with hardware and software DataCOLD 500 R The R Version has been developed for mounting in the truck cab The chassis of the recorder meets the dimensions of...

Страница 3: ... MENU S 12 3 1 Print menu 12 3 2 Alarm menu 14 3 3 User settings 15 3 4 Status menu 16 4 PARAMETER MENU 17 Menu 5 Temperature inputs settings 17 Menu 6 Digital inputs settings 19 Menu 7 Compartment settings 19 Menu 8 Alarm settings 20 Menu 9 Printer settings 20 Menu 10 General settings 21 Menu 11 Communication settings 21 5 ACCESSORIES AND SPARE PARTS 23 Enclosure A Technical data 25 Enclosure B R...

Страница 4: ...s The actual function of the buttons are always displayed on the bottom line To navigate through the menu s and change settings two different kinds of button functions are applicable To navigate through the menu s and to select parameters in the edit mode use the buttons as described below Blue Next menu point In edit mode Next choice from table Yellow Previous menu point In edit mode Previous cho...

Страница 5: ...be connected The main steps of the installation are described in the following chronological order 2 1 Positioning Connections Temperature sensors DataCOLD 500 T R temperature recorders can only be used with temperature sensors supplied with the DataCOLD 500 T R package Before the installation it is necessary to determine how many measurement points are required to retrieve the desired information...

Страница 6: ...serting it into the slot and bending the fixing blades to secure it in the facia Slide the recorder into the cage until it locks into position Once fitted into the cage the removal procedure is to insert the keys provided into the keyways at each side of the front face of the recorder to release the locks 1 Select a suitable position for the DataCOLD for example a free car radio slot in the dashbo...

Страница 7: ...corder should be mounted with the optional mounting kit This will replace a radio slot and can be fixed either on or under the dashboard as well as on the back wall Ensure that the position chosen allows the driver to see the display and operate the operator keyboard In addition it must be remembered that access to the printer drawer is required to replace the paper roll and this requires clearanc...

Страница 8: ...ch 10mm drill 2 Insert the four rubber mounting nuts Mount recorder using the four screws and washers provided note metal washer to be located on the outside of the mounting lug fixed to the box Ensure screws are screwed in tight 3 Drill hole large enough at suitable location through bulkhead to pass the temperature sensors through 4 Connect power cable directly to the battery as described in the ...

Страница 9: ...WARNING DISCONNECT THE RECORDER FROM THE BATTERY IF THE REFRIGERATION UNIT IS NOT USED FOR MORE THAN TEN 10 DAYS Page 9 62 61138 20 02 03 ...

Страница 10: ... polarity must be wired correctly Pin 2 4 6 and 8 are internally connected to ground Pin 1 3 5 and 7 are signal inputs Connector CON 4 temperature inputs DataCold 500 T R recorders offer the possibility to connect up to 4 temperature sensors Pin 1 8 are accordingly marked with T1 T4 T1 Pin 1 2 Pin 2 4 6 and 8 are signal inputs and pin 1 3 5 and 7 are internally connected to ground The polarity of ...

Страница 11: ...ground light must switch on after pressing any key except if using the permanent background light function and an acoustic signal audible The display shows the actual temperatures of the activated temperature inputs Temperature sensors After approx 5 minutes the temperature must be correctly displayed A value of 40 F 40 C indicates the possibility of a non connected sensor or a cable failure A val...

Страница 12: ...ameter report By pressing the Green button accept the parameter report will be printed after entering the correct PIN code 1 3 Print parameter report accept menu 3 1 4 Set print date With edit you can select a historical date for printing After confirmation of the date with accept you can select the required report with the Blue button Printing starts with a delay of 2 seconds 1 4 Set print date 0...

Страница 13: ...Page 13 62 61138 20 02 03 Print time period is set to 0 hour only the Day start time is applicable ...

Страница 14: ... will open With you can toggle between the pre set compartments Between the actual setting is displayed By pressing edit you can determine an alarm for the relevant compartment 2 1 Comp 1 off edit menu With you select the desired alarm type including alarm off By pressing accept the chosen alarm will be activated 2 1 Comp 1 Frozen accept cncl Note In case of an alarm condition an acoustic signal w...

Страница 15: ...tic European daylight savings time adjustment or No adjustment press Edit green button and the display will show ENTER PIN code The factory setting of the PIN code is 1212 3 2 Date setting ENTER PINCODE 1 2 3 4 Select Automatic Adjustment or No Adjustment select No Adjustment for North American use with Confirm the setting with accept Green 3 1 Time setting 14 09 03 cncl accept 3 3 3 Date setting ...

Страница 16: ... Buzzer frequency setting accept cncl 3 3 10 Buzzer on time setting Change the buzzer on time with and confirm it with accept 3 9 Buzzer on time setting accept cncl 3 3 11 Display software version Displays the actual software version of the recorder DATACOLD 500 1 00 8 11 12 2002 15 49 menu 3 4 Status menu Press RED button 4 The display mode will change between full menu information or only showin...

Страница 17: ...sor any time see menu 10 5 Parameter Settings ENTER PINCODE 1 2 3 4 After entering the correct PIN code you have access to the parameter menu s and the first menu level is displayed Select the desired menu with and press edit to enter one of the following parameter menu s 5 Temperature input settings 6 Digital inputs settings 7 Compartment settings 8 Alarm settings 9 Printer settings 5 Temperature...

Страница 18: ...Page 18 62 61138 20 02 03 T3 Input on off Menu structure as 5 1 T4 Input on off Menu structure as 5 1 ...

Страница 19: ...r door contacts active open 6 1 3 Alarm on off Activates the alarm for this input 6 1 4 Delay Time 10 Minute s Alarm delay time in minutes 6 2 Digital inp 2 on off Menu structure as menu 6 1 6 3 Digital inp 3 on off Menu structure as menu 6 1 6 4 Digital inp 4 on off Menu structure as menu 6 1 Menu 7 Compartment settings In this menu you have to configure the print and alarm functions for up to ma...

Страница 20: ...y time Each enabled alarm type can be activated by the user for any compartment although per compartment only one alarm group can be set at the same time 9 1 Graph upper limit 15 C Upper limit for graphical print out 9 2 Graph lower limit 30 C Lower limit for graphical print out Attention If the total temperature range between upper and lower limit is dividable by 9 you achieve a optimal result fo...

Страница 21: ...orrect recorder operation Select a code between 1111 and 9999 The factory setting is 1111 digit 0 is not available Attention Do not forget to note the new PIN code and store it in a safe place There is no master code available to get later access to the parameter menu 10 6 Correction factor 0 Correction factors from 9 to 9 for calibrating the temperature sensing circuitry To be used with diagnosti...

Страница 22: ...to Enclosure E wiring diagrams as above R TR to communicate with the RS 232 of the R TR unit micro without any control panel connected on the same port refer to Enclosure E wiring diagrams as above R TR control panel to communicate with the RS 232 of the R TR unit micro with one control panel or two control panels connected on the same port refer to Enclosure E wiring diagrams as above TMS protoco...

Страница 23: ...0585 66 Lock for Trailer box T 12 12 00585 67 Front lid Trailer box T 13 12 00585 68 Set of plastic bezel printer upper and lower 14 12 00585 69 Cable Grommets 3 grommets 15 12 00585 70 DataCOLD 500 R installation set with 4 connectors 16 12 00585 71 Universal mounting kit for cab version for DataCOLD R 17 12 00585 72 Mounting frame kit for DataCOLD R NS 12 00585 73 Main PCB 500R house display NS ...

Страница 24: ...Page 24 62 61138 20 02 03 ...

Страница 25: ...nector for external devices b Ventilation No special requirements DataCold 500 T R recorders are designed for use in an automotive environment c IP rating DataCOLD T Trailer version for outside mounting IP65 DataCOLD R Cab version for mounting in the cab IP22 d Dimensions W x H x D DataCOLD T 9 65 x 7 95 x 4 3 inches 245 x 202 x 110mm DataCOLD R 7 4 x 2 3 x 5 7 inches 188 x 58 x 145mm e Maintenanc...

Страница 26: ...ly upwards and pull the printer module carefully forward 2 Open the upper part of the front panel 3 Insert a new paper roll on the spindle 4 Place the printer module carefully back into the recorder until it is locked again Attention For the T version first check if the connector is fitted properly in the original position Page 26 62 61138 20 02 03 ...

Страница 27: ...int T4 No 7 1 9 Alarm on T4 No 7 1 10 Print D1 No 7 1 11 Print D2 No 7 1 12 Print D3 No 7 1 13 Print D4 No Yes with Carrier Unit 7 2 Compartment 2 Off 7 3 Compartment 3 Off 7 4 Compartment 4 Off 8 Alarm settings 8 1 Alarm group 1 Off Frozen 8 2 Alarm group 2 Off Chilled 8 3 Alarm group 3 Off Dry 8 4 Alarm group 4 Off Free text 9 Printer settings 9 1 Graph upper limit 59 F 15 C 9 2 Graph lower limi...

Страница 28: ...ing individual sensors Note that the effect on the measured and displayed Temperature is not linear Page 28 62 61138 20 02 03 Set the correction factor Connect to Temperature input 1 a precision resistor of 1500 Ω 0 1 Parameter Settings ENTER PINCODE 1 2 3 4 Enter the parameter menu by pressing the green button for 2 seconds The display will show ENTER PINCODE The factory setting of the pin code i...

Страница 29: ...GHT DIRECTLY TO THE BATTERY CONNECTOR 3 DIGITAL INPUTS configuration example 1 SUPPLY POSITIVE 2 REFRIGERATION 3 SUPPLY POSITIVE 4 BACK DOOR 5 SUPPLY POSITIVE 6 DEFROST RELAY 7 SUPPLY POSITIVE 8 SIDE DOOR relay door switch defrost relay door switch CONNECTOR 4 TEMPERATURE INPUTS 1 TEMPERATURE 1 2 TEMPERATURE 1 3 TEMPERATURE 2 4 TEMPERATURE 2 5 TEMPERATURE 3 6 TEMPERATURE 3 7 TEMPERATURE 4 8 TEMPER...

Страница 30: ... 1 GND 2 RXD 3 TXD 4 CTS 5 RTS Unit microprocessor connector Communication cable 2 way P N 22 60297 00 Y communication cable P N 22 60296 00 Control panel connector DataCOLD 500 c Serial communication with micro of the refrigeration unit with two control panels and RS232 interface 1 GND 2 RXD 3 TXD 4 CTS 5 RTS Power supply 12V Communication cable 3 way P N 22 60633 00 Control panel 1 connector RS ...