Carefully open the package and check that the following contents are complete: 

Wind Sensor 

TS805 

Rain Sensor 

TS906 

Thermo-Hygro Sensor 

TS21

 

Wireless Display 

WS-1517 

 

 

 

Requires 4 mounting 
screws  

 

Requires 2 AA batteries 
(not included) 

 

1 hex key  wrench 

 

 

 

 
 

 

Requires 4 mounting 
screws 

 

Requires 2 AA batteries 
(not included) 

 
 
 
 

 
 
 
 
 
 

 

Wall mount adapter 

 

Requires 2 AAA batteries 
(not included)  

 

 

 

7.5 V AC/DC 
adapter 
(included)  

 

4 AA batteries  
(not included)

 

Wind Sensor also Protected under 
U.S. Patent: 6,761,065; RE42,057

 

All items, including Wind Sensor, are Protected under U.S. Patents: 
5,978,738; 6,076,044; & 6,597,990 

 

 

 

Setup Instructions Step-by-Step 

 

IMPORTANT:

 Make sure to observe the correct polarity when inserting batteries 

(not included)

.  The "+" markings on the batteries must line 

up with the diagrams inside the battery compartments.  

Inserting the batteries incorrectly may result in permanent damage to the 

weather station.

 During the setup process, place the wireless display and the outdoor sensors on a surface with 5-10 feet between each 

sensor and the display.  

Batteries:

 We recommend using Alkaline batteries for the remote sensors and the weather station when temperatures are above 32°F 

(0°C). We recommend using Lithium batteries for the remote sensors when temperatures are below 32°F (0°C). 

Note:  

Setup all three sensors and allow them to run for at least 

two minutes

 before powering the weather station. Ensure all sensor 

readings are received to the weather station before mounting sensors outside.

 

 
STEP 1: 

Complete initial setup on a table with all components within 10 feet of each other. 

 

 

STEP 2: Wind 
Wind Cups 

1. 

With a flashlight, look into the mounting hole of the wind cups.  

2. 

Check that the set screw is backed off appropriately, not obstructing the opening. 

3. 

Place the wind cups over the axle shaft of the wind sensor and gently slide them into place. 

4. 

Use the hex key wrench tool provided to tighten the small set screw inside the cups. 

5. 

Test to assure the wind cups are securely mounted on the anemometer shaft and spin freely 

 
Battery installation 

1. 

Remove four (4) screws from the battery compartment. 

2. 

Open the battery compartment and install 2 AA Alkaline batteries (not included) matching the polarities shown. 

3. 

Replace the battery compartment door and secure the screws. 

 

STEP 3: Thermohygro 

1. 

Install 2 AAA Alkaline batteries (not included) matching the polarities shown in the battery compartment. 

2. 

Replace the battery compartment door.

 

 

 

STEP 4: Rain

 

1. 

Unlock the funnel-shaped top on the rain sensor by turning both knobs on the sides in a counter-clockwise direction.  

2. 

Lift the funnel-shaped top off the rain sensor bucket.  

3. 

Remove seven (7) small screws from the battery compartment cover. 

4. 

Insert 2 AA Alkaline batteries (not included), matching the polarities as shown in the battery compartment.  

Содержание WS-1517

Страница 1: ...32 F 0 C Note Setup all three sensors and allow them to run for at least two minutes before powering the weather station Ensure all sensor readings are received to the weather station before mounting...

Страница 2: ...ult settings for pressure and altitude sea level indoor outdoor temperature and humidity wind and rain readings etc STEP 6 Set Wind Direction 1 Wait until all the sensor readings are received by the w...

Страница 3: ...ce the range by one half Place sensors and weather station in desired locations and wait approximately 15 minutes before permanently mounting to ensure that there is proper reception Wind For most acc...

Страница 4: ...e elevation must be programmed according to GPS readings internet etc Sea Level Pressure reflects pressure changes in your surrounding metro area The Sea level barometric pressure value can be adjuste...

Страница 5: ...mfort level Wet Comfort or Dry Dew Point based on temperature humidity readings Temperature alarms can be set on the weather station Thermohygro sensor remote battery status is monitored on the main w...

Страница 6: ...he UP or DOWN arrow button to enable or disable it 3 If the alert is disabled the OFF will be displayed 4 Press ALARM CHART button to confirm selection and the weather station will return to the rainf...

Страница 7: ...RT button to confirm your selection 9 When programming is completed the weather station will return to the alarm selection screen Enable Disable Time Alarms 1 Press the ALARM CHART button to display t...

Страница 8: ...for pressure and altitude sea level indoor outdoor temperature and humidity wind and rain readings etc 6 Follow the program menu to set language and city code then any custom settings desired Changin...

Страница 9: ...9 9 Km h 173 7 Knots 89 3 m s Resolution 0 1mph 0 16 Km h Starting Threshold 3mph 4 8 Km h Wind Gust Speed Update Interval 33 seconds Wind Gust Sampling Interval 11 seconds Operating Range 100 feet 30...

Страница 10: ...BRE Nairobi Kenya 3 NBO Houston TX 6 Hou Brussels Germany 1 BRU Nanjing Nanking China 8 NKG Memphis TN 6 MEM Buenos Aires Argentina 3 BUA Odessa Ukraine 2 ODS Mexico City Mexico 6 MEX Budapest Hungary...

Страница 11: ...SUME LIABILITY FOR INCIDENTAL CONSEQUENTIAL PUNITIVE OR OTHER SIMILAR DAMAGES ASSOCIATED WITH THE OPERATION OR MALFUNCTION OF THIS PRODUCT THIS PRODUCT IS NOT TO BE USED FOR MEDICAL PURPOSES OR FOR PU...