40
Table 2. DISCHARGE MODE Current
User-selected Discharging
current
100 mA
250 mA
350 mA
Thereafter Charging
current
200 mA
500 mA
700 mA
Finally batteries will be fully charged in discharge mode and “Full” will be displayed. If user
presses DISPLAY key at this time, "charge" icon instead of "discharge" icon will be displayed.
REFRESH MODE
Old rechargeable batteries and those have not been used for a long time require refreshing.
This process will recover the optimum capacity of the rechargeable batteries. By pressing the
MODE key within 8 seconds after inserting the rechargeable batteries, the Refresh mode can
be selected.
Refresh mode will start with discharging the rechargeable battery, then charging it. The
repeated discharging and charging cycles will be launched until no further increase in the
measured capacities is estimated.