selecting all rechargeable batteries) or NUMBER key then MODE key (for selecting
individual rechargeable battery). 8 seconds after the last key press the LCD will blink
one time to indicate the end of changing.
z
When overheating condition occurs (over about 53°C, usually due to too high a charging
current selected), the charging will be stopped immediately and the display will shown
“000 mA”, the charging process will only resume once the temperature of the
rechargeable batteries drops to a safe level. If overheat conditions continue to occur,
the rechargeable batteries shall be taken out to cool down and then charged at a lower
current.
When the battery is overheated the
charging will ceases automatically.
“000 mA” will be displayed.
z
For new rechargeable battery it is recommended to charge it with 200 mA current for re-
conditioning it from the long storage status.
DISCHARGE MODE
Discharge mode will first discharge the rechargeable battery then charge it. It is for removing