background image

Model: 308-2316                          www.lacrossetechnology.com/support                                                             

Page | 18

  

Pressure Sensitivity Setting 

 

Pressure sensitivity settings are changed when your forecast icons do not seem to be changing 

properly after the weather station has been set up for a week. People who live near large bodies 
of water or in the desert may need to adjust this setting. Most of the time it will not need 

adjustment. 

Note:

 The lowest number is used near the coastline, the highest number is for the desert, and 

middle number is for everywhere else.  

 
1.

 

Hold SET button to enter setting mode. The word 

ZON

 will appear in the upper right corner 

and -5 will flash. 

2.

 

Press the SET button 11 times to select pressure sensitivity.  

3.

 

The number 

2, 3, 

or

 4

 will flash in the pressure area. 

4.

 

Press + or MIN/MAX button to select 2, 3, or 4 for a sensitivity setting.  

5.

 

Press the SET button to confirm selection and move to set the storm warning threshold. Or 

press the History button to exit setting mode. 

 

Storm Warning Threshold 

 

The Storm Warning Threshold is a low pressure warning that is set in the 
settings mode.   

 
1.

 

Hold SET button to enter setting mode. The word 

ZON

 will appear in the 

upper right corner and -5 will flash. 

2.

 

Press the SET button 12 times to select pressure sensitivity.  

3.

 

The number 

4

 will flash in the pressure area. 

4.

 

Press + or MIN/MAX button to select a number between 3 and 9 for a 
sensitivity setting.  

5.

 

Press the SET button to confirm selection then the History button to exit setting mode. 

 
When the warning threshold is met over a 3 hour period, the storm warning icon will flash for 3 

hours.  This warning is always active so you need to set the threshold to the highest number (9) 
if you do not want it to flash regularly (no sound). 

 

Changing Batteries 

 

Sensors only:

 When only changing batteries in the outdoor sensor only, allow up to 3 hours for 

the weather station to aquire the signal again. 

 
Weather Station & sensors:

 Remove batteries from the weather station & outdoor sensor and 

press a button 20 times. After 15 minutes, return to 

Setup Instructions Step-by-Step

 

WWVB Radio-controlled Time Signal 

 

WWVB Signal Search:

 The Thermo-hygro sensor receives the WWVB time signal and transmits 

it to the weather station. After power up, the thermo-hygro sensor will transmit weather data 

within the first 24 seconds. Then, the sensor will start radio controlled time (WWVB) reception.  

 

During the time reception period (maximum 5 minutes), no weather data will be transmitted. 

 

The LED indicator will be blink 5 times once WWVB signal is received.  

 

Weather data will be sent again once the WWVB search finished.  

 

If the WWVB time signal is not received, the thermo-hygro sensor will search every 2 hours 

until received.  

 

Weather data will be transmitted when not in search mode. 

 

Содержание 308-2316

Страница 1: ...weather station offers weather forecasting indoor outdoor temperature humidity wind rain data and precise atomic time date all on one comprehensive device Battery Compartment 3 AA Outdoor Temperature...

Страница 2: ...231W Connection Ports Rain Sensor TX231R Pole NOT INCLUDED Wind Cups Thermo Hygro TX231TH Note There are 2 different sizes of U bolts One set small for the rain mounting bracket and one set large for...

Страница 3: ...ure Sensitivity Settings 2 3 or 4 10 Storm Warning Threshold 3 9 10 Wind Speed Units mph km h m s knots and bft 10 Rainfall Units Inches or Millimeters 10 Quick Display Mode 10 Outdoor Temperature Win...

Страница 4: ...12 or 24 hour time display Perpetual calendar with Radio Controlled Clock RCC Time alarm High light LED backlight Wall hanging or free standing Synchronized instant reception Low power consumption ov...

Страница 5: ...transmitted when not in search mode Restart If there is no outdoor temperature or wind data after 10 minutes remove batteries from the weather station outdoor sensor and press a button 20 times After...

Страница 6: ...e rain sensor will need to be cleaned periodically 4 Batteries need to be changed every two years 5 Mount the sensors at least 6 from any building structure ground or roof top that may provide radiant...

Страница 7: ...e and humidity display 13 Outdoor temperature and humidity low alarm and high alarm 14 Temperature display unit 15 General outdoor alarm icon 16 Weather forecast icon 17 Weather tendency indicator 18...

Страница 8: ...sensitivity setting default 2 Note The lowest number is used near the coastline the highest number is for the desert and middle number is for everywhere else 13 Storm warning threshold setting defaul...

Страница 9: ...meric date will flash Press or MIN MAX button to select the correct date Press the SET button to confirm selection and move to the date format 17 Press the SET button to confirm selection and select F...

Страница 10: ...ree hour period 30 The number 4 storm warning threshold will flash in the pressure area 31 Press or MIN MAX button to select a threshold from 3 9 for the storm warning 32 Press the SET button to confi...

Страница 11: ...Absolute Pressure Wind Speed or Wind Gust display 5 Press and release the SET button three times The Wind Speed number will flash 6 Press the or MIN MAX buttons to display Wind Speed or Wind Gust Rain...

Страница 12: ...t 7 days Monthly rainfall rainfall over the past 30 days Total rainfall Total since the startup of weather station until reset To view different rainfall readings 1 Press and release the SET button fo...

Страница 13: ...17 Press the ALARM button to activate or deactivate the alarm 18 Press the SET button to select the Wind Chill High Alarm 19 Press the or MIN MAX buttons to adjust the wind chill value 20 Press the AL...

Страница 14: ...utton to activate or deactivate the alarm 15 Press the SET button to select the Outdoor Temperature Low Alarm 16 Press the or MIN MAX buttons to adjust the temperature value 17 Press the ALARM button...

Страница 15: ...aximum records and seven minimum records to view with time and date of occurance You may choose to view and or reset any or all of these records 1 Press the MIN MAX button once to enter MAX mode 2 Pre...

Страница 16: ...speed maximum value with time and date stamp 17 With the value flashing press the SET button to reset the record to current value date and time 18 Press the button to view wind gust maximum value with...

Страница 17: ...w wind chill temperature minimum value with time and date stamp 11 With the value flashing press the SET button to reset the record to current value date and time 12 Press the button to view dew point...

Страница 18: ...in the pressure area 4 Press or MIN MAX button to select a number between 3 and 9 for a sensitivity setting 5 Press the SET button to confirm selection then the History button to exit setting mode Wh...

Страница 19: ...range 300 1100hPa 8 85 32 5inHg Alarm interval 120 seconds Outdoor Temperature Range 40 F to 149 F 40 C to 65 C OFL outside this range Alkaline Batteries 20 F to 149 F 28 8 C to 65 C Lithium Batteries...

Страница 20: ...dren The product is not to be used for medical purpose or for public information It is intended for home use only The specs of this product may change without prior notice Improper use or unauthorized...

Страница 21: ...ipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device must not be co located or operat...

Отзывы: