CP-2500
Installation Manual
0040-17251-01
General Information
Page 1-5
Revision D
March 15, 2018
1.4 MODIFICATIONS
Modification (MOD) for the CP-2500 is identified by an entry on the S/N & ID tag on individual units.
Table 1-2: Hardware Modifications
MOD #
EFFECTIVITY / COMPLIANCE
DESCRIPTION
None
1.5 CONFIGURATON VERSIONS
Configuration version for the CP-2500 is shown on the display during startup.
Table 1-3: CP-2500 Configuration Versions
PART NUMBER
FIRMWARE REVISION
HARDWARE REVISION
CP-2500
(9080-17250-01)
09
01
CP-2500
(9080-17250-02)
15, 16, 17
01
CP-2500
(9080-17250-12)
15, 16, 17
01
Note – An update to the firmware requires the unit be sent to ACSS for an exchange.
1.6 INTERFACES
The electrical characteristics of all input and output signals are detailed in Appendix A.
1.7 EQUIPMENT REQUIRED NOT SUPPLIED
ITEM
DESCRIPTION
Cables and Wiring:
The installer will supply all system wires and cables. All wires are #22 AWG as
noted in the installation section. Use
MIL-DTL-16878 or equivalent wire and
use M27500 or equivalent for twisted shielded wire for installation.
Circuit Breaker:
Installer responsible for determining appropriate circuit breakers needed to
protect aircraft wiring. Manufacturer recommends the following:
•
1.0 amp breaker (connected to its own breaker with 14 or 28 VDC input)
•
The CP-2500 can be installed on the same breaker as the Lynx MSS.
Refer to the appropriate Lynx MSS Installation manual for breaker and
interconnect information.
Connector Installation Crimping Tool: M22520/2-01
Positioner: M22520/2-10
Insertion/Removal: M81969/14-10