KeyAT-5 Keyboard Port Adapter
L3 Systems
15
11/14/2011
The configuration settings are defined as follows.
The underlined characters represent the minimum
required entry in each field:
9600
–
Baud Rate
: 1200, 2400, 4800, 9600, 19200, 38400,
and 57600 are valid. 9600 is the default setting.
8
–
Number of RS232 Data bits
: Valid settings are 7 or 8.
This must be 8 if parity is disabled. The default is 8.
NoPar
–
RS-232 Parity
: Valid settings are NoPar for no
parity, Even for even parity,
and Odd for odd parity. The
default is NoPar.
Yecho
– Echoing
RS-232 characters
: Valid settings are
Necho for no echo, and Yecho for echo enabled. The
default is Yecho.
YesCmd
–
Command mode
: YesCmd enables KeyAT
commands and NoCmd
disables these commands. The
default is YesCmd.
NoCR
–
CR Pass through mode
: NoCR does not send
through the <CR> or <ENTER> at end of command
line. YesCR will send it through.
LM
–
Entry Mode
: LM (default) enables “line Mode”, IM
enables Immediate mode
OD
–
End-of-line character
: Default is 0D, (<CR> or
<ENTER> character)
7E
–
Command prefix character
: Default is 7E, tilde (~)
character.
03
–
Delay between keystrokes
: Default is 03, (30ms).