5.1.2 Alarms Page BIT Details
Expanded details of specific BIT failure can be reviewed from the Alarms page. Operators can access the Alarms
page by selecting the Alarms action field located at the bottom of user menus. The Alarms page will list the following
BIT details:
•
Alarm Timestamp
•
Alarm Description
•
Alarm Summary
•
Alarm BIT Error Code
Alerts are retained on the alarms page until the system component returns to its fully functioning state. Restoring a
component’s function might be accomplished by restarting the system, running a BIT test, or the component may
require maintenance. The software is capable of storing up to 16 alert messages only. Additional alerts are added
by dropping the previous alerts with the oldest time stamp.
Table 5-1 Status Indications in the System Status Main Menu
Status
State
Description
Recommended Action
OK,
MINOR,
MAJOR
STARTUP
Component Initializing:
• Some components are warmed or cooled
before they can be operated.
None.
–
N/A
Communication failure with component.
Review the Alarms page.
OK
OPERATIONAL
Component is in a fully functioning state.
None.
OK
STOWED
Turret is operational but in the Stow position
Steer turret to Forward or manual
position to establish video.
MINOR
OPERATIONAL
Component BIT test failed but still functional:
• Component capabilities are out of tolerance,
e.g. focus position exceeded tolerance set
point.
Review BIT from the Alarms page.
MAJOR
OPERATIONAL
Component BIT test failed but still functional:
• The system has forced a partial shutdown of
capability. For example, the EOW mechanism
caused Iris function to shutdown, but zoom and
focus capability remain.
Review BIT from the Alarms page.
MAJOR
FAILED
Component BIT failed and is shutdown.
• The system has forced a shutdown of a
capability. For example, the internal gimbal
temperature is too hot so the EON is shutdown.
Review BIT from the Alarms page.