Towfish Commands
C-17
C.6 Towfish Commands
Although sonar control is normally performed using the Ethernet or NMEA
interfaces, direct control of the towfish is possible. Various parameters of sonar
operation are performed in the towfish, such as waveform selection, TVG page,
etc. These parameters are set by transmitting control messages to the towfish via
the downlink telemetry. The control messages take the form:
$XYd <CR><LF>
where X is the destination, Y is the command and dd is the data for the command.
The destination of the command instructs the downlink processor where to route
the command as there are multiple possible destinations for a command. For
example, one can send commands to the on-board compass, the Transmitter PCB,
the MUX PCB, etc. For the 5000 System the possible destinations are M for the
MUX PCB, T for the Transmitter PCB and C for the Compass module. For the
3000 System the possible destinations are M for the MUX PCB, S for the SBP, C
for the Compass module and A for the auxiliary RS-232 port. For the System 5900
the possible destinations are M for the MUX board, D for the DSP board, X for
Transmitter board #1 and Y for Transmitter board #2.
Issuing commands to the towfish can be done in a number of ways. The most
straightforward technique is to use the towfish command interface in the SonarPro
software. The desired command is simply entered and then sent to the towfish.
Another technique is to use the $PKLA,FC command via the NMEA interface
(COM2). The desired command is simply typed after the ‘FC’. For example,
$PKLA,FC$MT9<CR><LF>. The final technique is to use the towfish diagnostics
connectors located inside the TPU. On the 5000 System a special cable is needed
to break out a header on the DEMUX board to a DB-25 connector. This connector
can then be hooked to a terminal and direct control of the towfish achieved. This is
normally reserved for factory use. For the 3000 System a terminal can be
connected to COM3 on the DEMUX board. Once again, this is normally reserved
for factory use.
C.6.1 5000 System MUX Commands
The following commands are available to control the 5000 System Multiplexer:
$MTd:
Sets the TVG page where d = 0 – F in hexadecimal format.
The default page is 7. Increasing the value increases the
gain by 3 dB for each increment. Conversely decreasing this
value decreases the gain by 3 dB.
NOTE
The systems are available with a range of pressure sensors. This is
the reason that absolute depth is not calculated by the TPU.
Содержание SERIES 5000
Страница 27: ......
Страница 59: ......
Страница 162: ...Splashproof TPU Drawings 6 13 ...
Страница 163: ...6 14 CHAPTER 6 Splashproof TPU Series 5000 Sonar System Operations and Maintenance Manual P N 11210060 Rev 13 0 ...
Страница 164: ...Splashproof TPU Drawings 6 15 ...
Страница 165: ...6 16 CHAPTER 6 Splashproof TPU Series 5000 Sonar System Operations and Maintenance Manual P N 11210060 Rev 13 0 ...
Страница 166: ...Splashproof TPU Drawings 6 17 ...
Страница 167: ......
Страница 170: ...A 3 Figure A 1 Cable Length vs Towfish Depth Graph 1 ...
Страница 172: ...A 5 Figure A 3 Cable Length vs Towfish Depth Graph 3 ...
Страница 174: ...A 7 Figure A 5 Cable Length vs Towfish Depth Graph 5 ...
Страница 175: ......
Страница 179: ......
Страница 203: ......
Страница 262: ...NMEA 0183 Formats and Information D 59 D 13 NMEA 0183 Formats and Information ...
Страница 264: ...NMEA 0183 Formats and Information D 61 ...
Страница 265: ......
Страница 268: ...E 3 ...
Страница 270: ...E 5 ...
Страница 272: ...E 7 ...
Страница 274: ...E 9 ...
Страница 276: ...E 11 ...
Страница 278: ...E 13 ...
Страница 280: ...E 15 ...
Страница 282: ...E 17 ...
Страница 283: ......