Mixed Air Temperature Mode
............................................................................................... 26
MRT Control……. ............................................................................................................................................. 26
MRT-Expert Control .......................................................................................................................................... 26
MDT and MDT-Expert Controls........................................................................................................................ 26
Building Pressure Mode
........................................................................................................ 26
MRT and MDT Controls .................................................................................................................................... 26
MRT-Expert and MDT-Expert Controls ............................................................................................................ 26
100% Outside Air
................................................................................................................. 27
Minimum Ventilation
......................................................................................................... 27
Freezestat
............................................................................................................................... 27
Clogged Filter
........................................................................................................................ 27
User Configured PID Control
......................................................................................... 27
Direct Acting
............................................................................................................................ 28
Reverse Acting
....................................................................................................................... 29
Unit Resets
............................................................................................................................. 31
ALARM
..................................................................................................................................... 31
CALIBRATE
............................................................................................................................ 32
FAN COUNT
........................................................................................................................... 32
HEATING COUNT
................................................................................................................. 32
COOLING COUNT
................................................................................................................. 33
Multiplexed Inputs
.............................................................................................................. 33
Clock Set
................................................................................................................................. 34
Diagnostics – Critical Alarm Codes
........................................................................... 34
ALARM CODE:
Low Discharge Temperature
................................................................. 34
SOLUTION:
If burner was operating prior to shutdown (check prior alarm log) ..................................... 34
SOLUTION:
If burner was not operating prior to shutdown (check prior alarm log) ............................... 35
ALARM CODE:
Safety Circuit Open
................................................................................. 37
SOLUTION:
If fan is not running (check prior alarm log) ........................................................................ 37
SOLUTION:
If fan is running (check prior alarm log) .............................................................................. 37
ALARM CODE:
Burner Status
........................................................................................... 38
SOLUTION:
Inspect burner control circuit and burner ............................................................................ 38
ALARM CODE:
Burner Hand
............................................................................................. 39
SOLUTION:
Inspect burner control circuit.
This alarm has the potential to be a very serious problem.
Close the manual gas valves immediately if the fan is not running.
.................................................................. 39
ALARM CODE:
Flame Failure
........................................................................................... 40
SOLUTION:
Investigate flame relay ........................................................................................................ 40
Содержание AireLogic
Страница 1: ...1 AireLogic Digital Control System User Manual Rev 04 11 13...
Страница 53: ...53 Appendix I 10K Thermistor Output Curve...
Страница 54: ...54 Appendix II Airflow Station Layout...
Страница 59: ...59 Typical Wiring Schematic RECIRCULATING WDF MODEL DIAGRAM...
Страница 60: ...60 NON RECIRCULATING WDF MODEL DIAGRAM...