30
The device and principle of operation L-502.
Description
Desig-
nation
Timing sample
Minimum
Typical
Maximum
The time to set the state "1" to
START_OUT before the front
CONV_OUT
(start of data collection)
t
ST_SU
45 ns
Hold time of state "1" to START_OUT
after the front CONV_OUT
(termination of data collection)
t
ST_H
150 ns
The time to set the data at the DI input
t
DI_SU
5 ns
Data hold time at the DI input
t
DI_H
-1 ns
DO delay time relative to the front
CONV_OUT
t
DO
6 ns
The group delay time of the signal at the
output of the DAC relative to the front
CONV_OUT
t
DAC
0,7 µs