114278-01C
15
WIRING DIAGRAM
Power Plug
120V/60Hz
Blue
Blue
White
Photocell
gn
ton Contro
Assemb
y
Green
Black
Black
Green
Red
Black
Yellow
Ye
llo
w
Motor
Ignitor
Thermostat
Photocell
Photocell
Ignitor
Motor Return
AC Neutral (L2)
120V (L1)
Ignitor
Motor
White
ON/OFF Switch
with Light
2
1
3
Figure 30 - Wiring Diagram
REPLACEMENT PARTS
Note:
Use only original replacement parts. This
will protect your warranty coverage for parts
replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized dealers of this product. If they
canʼt supply original replacement part(s), call
L.B.WHITEʼS Technical Service Department at
1-800-345-7200 for referral information.
When calling L.B.WHITE, have ready:
• your name
• your address
• model and serial numbers of your heater
• how heater was malfunctioning
• purchase date
Usually, we will ask you to return the part to the
factory.
PARTS NOT UNDER WARRANTY
Contact authorized dealers of this product. If
they canʼt supply original replacement part(s),
call L.B.WHITE at 1-800-345-7200 for referral
information.
When calling L.B.WHITE, have ready:
• model and serial numbers of your heater
• the replacement part number
TECHNICAL SERVICE
You may have further questions about installa-
tion, operation, or troubleshooting. If so, contact
L.B.WHITEʼS Technical Service Department at
1-800-345-7200. When calling please have your
model and serial numbers of your heater ready.
ACCESSORIES
Purchase accessories and parts from your nearest
dealer or service center. If they can not supply
these accessories or parts, contact L.B. White at
1-800-345-7200 for referral information.
L.B. White Co., Inc.
W6636 L.B. White Road
Onalaska, WI 54650
1-800-345-7200
AIR GAUGE KIT - 500-20907
Special tool to check pump pressure.
IGNITION CONTROL ASSEMBLY/
PHOTOCELL TESTER - 500-20913
Special tool used to test the ignition control as-
sembly and photocell.