BURNER ORIFICE

CAUTION

Allow the heater to cool before servicing.

1. Disconnect the heater from its electrical supply and

close all fuel supply valves to inlet of the heater.

2. Remove the case top from the heater and the right

side panel (when viewed from air inlet end of heater).

3. Disconnect the electrical lead from the igniter.

4. Remove the screw that secures the igniter to the

burner plate.  Pull the igniter from the burner plate.

5. Install the new igniter by reversing the above

procedures.

IMPORTANT

The tip of igniter electrode should be 1/8 in. gap from the

burner plate when the igniter is installed.

6. Reinstall the case top and side panel.

7. Reconnect the heater to its electrical supply.

8. Start the heater and check for proper operation.

FIG. 9

IGNITER

CAUTION

Allow the heater to cool before servicing.

RING, FLAT

ORIFICE

BURNER PLATE

RING, BOWED

MANIFOLD

IGNITER

BURNER PLATE

1/8

1. Disconnect the heater from its electrical supply and

close all fuel supply valves to the inlet of the heater.

2. Remove the case top from the heater.

3. Loosen the compression nut at the orifice inlet using

the appropriate wrench.

4. Remove the bowed retaining ring nearest the

compression nut.

5. Reaching down the heater barrel, pull the orifice from

the burner plate.

6. The replacement orifice ships with two (2) retaining

rings.  Attach the flat ring to the orifice as shown in

Fig. 8.  Reaching down the barrel, position the orifice

into the burner plate.  Secure the orifice into position

using the bowed retaining clip.  

7. Thread the compression nut onto the orifice and

tighten securely.

8. Reconnect the heater to its electrical supply and open

the fuel supply valves to the heater.

9. Start the heater and check for proper operation.

Leak check the compression sleeve and orifice

connection.

10. Shut the heater off and reinstall the top cover.

FIG. 8

13

Содержание Tradesman CP100

Страница 1: ...nts you may have call us toll free at 1 800 345 7200 Owner s Manual and Instructions Tradesman Construction Heater ATTENTION ALL USERS This heater has been tested and evaluated by CSA International in...

Страница 2: ......

Страница 3: ...n lead to property damage personal injury or loss of life GENERAL HAZARD WARNING Failure to comply with the precautions and instructions provided with this heater can result in Death Serious bodily in...

Страница 4: ...tor or the L B White Co Inc for assistance or if you have any questions about the use of the equipment or its application The L B White Co Inc has a policy of continuous product improvement It reserve...

Страница 5: ...pping Weight lbs Electrical Supply Volts Hz Phase Amp Draw Dimensions Inches L x W x H Minimum Safe Distances From Nearest Combustible Materials Minimum Ambient Temperature In Which Heater May Be Oper...

Страница 6: ...ous injury or death Symptoms of carbon monoxide poisoning can include headaches dizziness and difficulty in breathing Asphyxiation H Hazard Some p people c cannot s smell w well S Some p people c cann...

Страница 7: ...backflash switch Never operate this heater with any safety device that has been bypassed Do not operate this heater unless all of these features are fully functioning 7 Do not operate the heater with...

Страница 8: ...on heater or within owner s manual 8 This heater is provided with a pre set single stage regulator and a gas hose as specified by L B White Co of proper length diameter and construction Make sure thes...

Страница 9: ...all connections securely 4 Check a all c connections f for g gas l leaks u using a approved gas l leak d detectors HOSE AND REGULATOR ASSEMBLY FIG 2 1 Fasten the carrying handle to the heater case to...

Страница 10: ...input rating stamped on the dataplate of the heater Do not use an orifice size different than specified for the input rating of this heater fuel type configuration and altitude FIG 3 If the heater is...

Страница 11: ...VALVE 2 The valve can be adjusted to deliver either minimum heat or maximum heat When the valve handle is parallel to the gas flow the valve is completely open to deliver maximum heat output Refer to...

Страница 12: ...condition of the heater before each use to determine if a general cleaning is necessary a Use compressed air or a soft brush to clean interior and exterior surfaces and component parts of dust and di...

Страница 13: ...vice Instructions MOTOR AND FAN ASSEMBLY THERMOCOUPLE CAUTION Allow the heater to cool before servicing BURNER PLATE THERMOCOUPLE CLIP 1 2 INCH 1 Disconnect the heater from its electrical supply and c...

Страница 14: ...FLAT ORIFICE BURNER PLATE RING BOWED MANIFOLD IGNITER BURNER PLATE 1 8 1 Disconnect the heater from its electrical supply and close all fuel supply valves to the inlet of the heater 2 Remove the case...

Страница 15: ...e case top 7 Reconnect the heater to its electrical supply and open all fuel supply valves to the heater 8 Start the heater and check for proper operation FIG 10 CAP SAFETY CONTROLVALVE LOW PRESSURE G...

Страница 16: ...n the backside of the switch Be careful not to melt the switch housing when testing 3 Within thirty seconds you should here a pop coming from the switch indicating that the electrical contacts have op...

Страница 17: ...ctively use these flow charts you must first identify the problem The problems are numbered sequentially along with a brief explanation of each problem Start at the diamond closest to the identified p...

Страница 18: ...air or Replace as Necessary Yes No Yes Yes Replace Power Cord Is Proper Voltage Supplied to heater A Check Circuit Breakers B Check for Proper Length and Gauge of Extension Cord if used C Contact a qu...

Страница 19: ...e Heater See Dataplate Provide Proper Gas Pressure to Heater Inlet Check High Voltage Lead for Continuity Replace if Necessary Check Igniter Gap Gap is 1 8 in Reposition the Igniter Plugged Burner Ori...

Страница 20: ...k Determine Cause of Backflash Switch Opening See Problem 5 No Have Individual Wires Been Checked from thermocouple Energy Cut Off to Relay and Backflash Switch Check Individual Wires for Continuity N...

Страница 21: ...hten the Set Screw Yes No Yes Yes Is Heater Receiving Proper Ventilation Increase Room Ventilation or Reposition Heater to Avoid Recirculation of Hot Air Bend Switch Mounting Bracket Away from Burner...

Страница 22: ...TRICAL CONNECTION DIAGRAM WARNING THIS HEATER MAY START AT ANYTIME CAUTION REFERTOTHE HEATER S ELECTRICAL CONNECTION DIAGRAMWHEN SERVICINGTO AVOIDWIRING ERRORS AND HEATER MALFUNCTION CHECK FOR PROPER...

Страница 23: ...used on automatic spark ignition control systems Ignites gas by spark Motor Converts electrical energy into mechanical energy It is used in conjunction with the fan blade to pull air into the burner f...

Страница 24: ...Parts Identification PARTS SCHEMATIC 33 32 31 29 28 30 27 26 24 23 25 19 8 9 10 11 12 13 14 15 18 21 22 20 17 16 7 4 14 1 2 3 6 5 23...

Страница 25: ...26 Igniter 21803 27 Ring Bowed 08460 28 Ring Flat 05847 29 Orifice with Rings 21802 30 Chamber Heat with Igniter Orifice and Burner Plate 21799 31 Guard Inlet 21792 32 Case Top 21793 33 Handle with Sc...

Страница 26: ...the d date o of p purchase by t the e end u user Warranty is automatic if a component is found defective within 12 months of the date code marked on the part If the defect occurs more than 12 months l...

Отзывы: