Indoor Ventilation Kit

Indoor Installation Kit • Therma Grow

3

CUT DUCT TO PROPER LENGTH,  

NO KINKS OR SAGGING

B.  Air Inlet Installation and Assembly  

(Refer to Fig. 2)

1.  From the exterior, slide the air inlet through the 

opening. The inlet’s mounting flange must be located 

against the flat exterior of the building. Mark and drill 

1/8 in. pilot holes at all flange screw holes. Secure 

the inlet to the wall with the screws provided. Seal the 

inlet’s flange edges.

2.  Evenly position the air inlet hood over the inlet at 

the exterior of the building. Mark and drill 1/8 in. pilot 

holes at all flange holes. Secure the inlet hood to the 

exterior wall with screws from kit. Seal the hood’s 

flange edges.

3.  Assemble the motor with bracket to the air inlet 

transition sleeve. Use the nuts and screws from the kit. 

Do not tighten at this time

4.  Assemble the motor arm to air inlet’s linkage arm. See 

detail in Fig. 2. Tighten the screw securely.

 

5.  Push the motor with bracket toward the wall until slots 

in bracket stop against mounting screws, and shutters 

are fully closed. Securely tighten all motor bracket 

screws. See detail in Fig. 2.

6.  Mount the air proving switch assembly to the transition 

sleeve. Tighten the mounting screws securely.

C. Locating and Installing the Exhaust Fan

1.  The exhaust fan must be located at an upper area 

of the end wall opposite from the heater, preferably 

in an area higher than the heater’s discharge. See 

Fig. 3. The exhaust fan does not need to be directly 

in line to the heater.

2.  Provide a 10 1/4 in. x 10 1/4 in. square and level  

opening. Suitable framing may be required for  

mounting.

3.  Position the kit through the opening from the inside of 

the greenhouse. The shutters are gravity operated and 

must be installed so the shutters drop to closed after 

being lifted open.

 

-- Check the assembly with a level before installing.

--  Mark and drill 1/8 in. pilot holes at all locations in the 

exhaust fan’s mounting flange.

--  Secure with 1/2 in. screws from the kit. See Fig. 4. 

-- Seal the appropriate areas to prevent water entry.

D.  Wiring the Exhaust Fan and Air Inlet 

Shutter Motor to the Heater

1.  Select a location for an electrical junction box near 

the heater. Mount the junction box.

2.  Open the heater’s control box. Remove the hole plug 

from the control box base and the wire cap(s) from 

the wire(s) labeled TO VENTILATION MOTORS. 

See Fig. 5.

3.  Route an appropriate length and gauge of electrical 

wiring from the junction box up to the bottom of the 

control box and through this hole.

4.  Connect an appropriate length and gauge of electri-

cal wiring to the leads of the exhaust fan motor and 

air inlet shutter motor.

--  Route this wiring to the electrical junction box and 

connect it to the wiring leading to the heater’s control 

box.

-- Use wire nuts provided.

--  Refer to the appropriate electrical connection diagram 

on page 6.

5.  Proceed to further wiring instructions, page 4, for 

the Therma Grow™ 120 Plus/220 Plus or Therma 

Grow™ 120/220 heaters.

 

Содержание Therma Grow 120

Страница 1: ...g must be done in accordance with local codes In absence of local codes follow ANSI NFPA 70 National Electrical Code General Information Proper installation for heaters located within the greenhouse r...

Страница 2: ...Air Inlet Locations END WALL DUCT COLLAR INSTALLED TO AIR INLET OF HEATER CLAMP CLAMP COLLAR WITH COVER INSTALLED TO AIR INLET 10 FT MAX FROM AIR INLET OF HEATER TO AIR INLET ALTERNATE INLET LOCATIONS...

Страница 3: ...n the heater s discharge See Fig 3 The exhaust fan does not need to be directly in line to the heater 2 Provide a 10 1 4 in x 10 1 4 in square and level opening Suitable framing may be required for mo...

Страница 4: ...OUNTED INSIDE GREENHOUSE GAS SUPPLY INLET HOOD MOTOR MOTOR ARM 10 32 X 1 1 4 MACHINE SCREW INSERT 10 32 WASHER WASHER SPACER 10 X 7 8 AIR PROVING SWITCH SCREW 1 4 X 3 8 2 NUT 10 32 WITH STAR WASHER 4...

Страница 5: ...ee way terminal See Fig 7 Connect this assembly to terminal IND on the ignition control FIG 7 3 Connect the wiring from the junction box to the heater s control box as follows Use wire nuts supplied f...

Страница 6: ...ontrol wiring instruc tions Ensure 115 VAC is supplied to the exhaust fan motor and air inlet shutter motor Both will operate when the heater starts a On start up the heater s fan motor will run for 5...

Страница 7: ...TH SCREWS 500 25314 SHUTTER MOTOR 500 26012 BRACKET WITH MOUNTING SCREWS AND NUTS LEAD A LEAD A BUTT SPLICE WIRE FROM IGNITION CONTROL WITH TERMINAL REMOVED IND L1 HSI HSIG L2 W PSI FSI GV PSO FSG C A...

Страница 8: ...REE WAY TERMINAL LEAD A BUTT SPLICE NEUTRAL NEUTRAL 115 VAC 115 VAC EXHAUST FAN CONNECTIONS AIR INLET SHUTTER MOTOR CONNECTIONS Contact your local L B White dealer for replacement parts and service Yo...

Отзывы: