9
E
N
G
L
I
S
H
Troubleshooting
Models CR015 and CR030
Sun Blast Operating Instructions and Parts Manual
1. Unit will not light.
1. Valve on propane cylinder not open.
1. Open cylinder valve by turning counterclockwise.
2. Propane cylinder empty
2. Have cylinder refilled.
3. Regulator not in "High" position
3. Turn regulator to "High" position.
4. Excess flow device triggered.
4. Close cylider valve, wait 5 minutes and reopen slowly.
5. Defective Regulator.
5. Replace Regulator assembly.
2. Burner will not stay lit when 1. Tilt switch open
1. Correct alignment of unit to ensure it is vertical.
gas valve plunger released.
2. Wiring of thermocouple
2. Check wiring connections are properly engaged.
3. Defective thermocouple
3. Replace thermocouple.
4. Defective tilt switch
4. Replave tilt switch.
5. Defective gas valve
5. Replace gas valve assembly.
3. Excessive flames coming out 1. Debris or spider webs in mixing tube
1. Clean burner tube with bottle brush, rinse in water
of burner, not glowing red.
or burner.
and drain thoroughly before reintsalling.
2. Clogged orifice
2. Remove and clean using compressed air.
4. Flames flashback/burn inside 1. Debris or spider webs in mixing tube.
1. Clean burner tube with bottle brush, rinse in water
the mixing tube
and drain thoroughly before reintsalling.
2. Clogged orifice
2. Remove and clean using compressed air.
PPRRO
OBBLLEEM
M
PPO
OSSSSIIBBLLEE CCA
AUUSSEE
CCO
ORRRREECCTTIIV
VEE A
ACCTTIIO
ONN
Notes
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!