main burner in operation, check all connections, hose
connections, fittings and joints as well as the gas
control valve inlet and outlet connections with
approved gas leak detectors. If a leak is detected,
check the components involved for cleanliness in the
threaded areas and proper application of pipe
compound before further tightening. Further tighten
the gas connection as necessary to stop the leak. If
necessary, replace the parts or components involved
if the leak cannot be stopped. Ensure all gas leaks
have been identified and repaired before proceeding.
16. A qualified service agency must check for proper
operating gas pressure upon installation of the
heater.
17. Light according to instructions on heater or within
owner's manual.
18. This heater can be configured for use with either L.P.
gas vapor withdrawal or natural gas. Consult the
dataplate, located on the exterior of the burner end
door for the gas type of the specific heater. Do not
use the heater in an L.P. gas liquid withdrawal system
or application. If you are in doubt, contact your local
agent or the L.B. White Co., Inc.
19. Take time to understand how to operate and maintain
the heater by using this Owner’s Manual. Make sure
you know how to shut off the gas supply to the heater.
Contact your fuel gas supplier if you have any
questions.
20. Any defects found in performing any of the service or
maintenance procedures must be eliminated and
defective parts replaced immediately. The heater
must be retested by a properly qualified service
person before placing the heater back into use.
9