manualshive.com logo in svg
background image

PARTS LIST

26

Model

Item

Description

I

17

I

34

1

Inner Cone

130-09585

130-09557

Outer Cone

130-09588

130-09556

Combustion Cone Kit with Gasket

500-21087

500-21088

2

Gasket

130-09586

130-09560

3

Plate, Burner                                                                                                         130-21953-03  130-22212-03

4

Igniter

120-22612

5

Cover, Igniter Mounting

220-22786

6

Spacer

130-09568

7

Screw 10-32 x 1 1/2

130-23636

8

Nut 10-32

130-09578

9

Chain Assembly

--

400-09566

10

Key Ring

130-09620

11

Link, Chain Adjustment

--

130-09697

12

Clip, Chain Hanging

--

240-09567

13

Lead, Igniter w/ Boot

120-22703

14

Connector, Liquid Tight

120-08948

16

Control, Direct Spark Ignition

120-22715

17

Switch, On/Off

120-22714

18

Boot, On/Off Switch

130-09916

19

Bracket, Control Box

225-22661

225-22616

20

Control Box Cover w/ Gasket

500-23180

21

Control Box Bottom

500-23179

22

Bushing

130-01544

23

Adapter, Hose

310-01098

24

Valve, Gas Control w/ Electrical Leads

400-22705

and Screen

25

Orifice, Burner                                                                  L.P. Gas

310-21562

310-20573

Natural Gas

310-09776

310-21000

26

Injector Body w/ Air Register Plate                                 L.P. Gas

500-21838

500-20672

Natural Gas

500-21837

500-21559

27

Retaining Screw for Injector Tube

130-09572

28

Adapter 3/8 NPT x 1/8 BSP

310-22694

29

Lead, Black, On/Off Switch to Ignition Control

120-22610

30

Hose, Gas   1/4 in. x 6 ft.  Rigid x Swivel, Poultry

400-20495

1/4 in. x 10 ft.  Rigid x Swivel, Poultry

400-20496

1/4 in. x 12 ft.  Rigid x Swivel, Poultry

400-20497

1/4 in. x 6 ft.  Swivel Both Ends, Swine

400-20499

1/4 in. x 10 ft.  Swivel Both Ends, Swine

400-20242

1/4 in. x 15 ft.  Swivel Both Ends, Swine

400-20500

31

Filter Kit

500-20427

500-20428

31A

Sleeve

400-20321

400-20421

31B

Filter

130-20361

130-20429

32

Plug

130-20358

33

Cord, Power

120-22704

34

Screw, Igniter Mounting

130-06658

35

Tube, Injector

310-09597

36

Lock Nut

120-08948

37

Screw, Injector Body

130-09575

38

Screw, Direct Spark Ignition

130-02330

39

High Limit Switch, Manual Reset

120-23148

40

Screw, High Limit Switch

130-22783

41

Gasket, Liquid Tight

130-22565

42

Wire, High Limit Switch

120-22610

Содержание I17

Страница 1: ...may have call us toll free at 1 800 345 7200 Owner s Manual and Instructions Spark Ignition Infraconic Agricultural Building Radiant Heaters ATTENTION ALL USERS This heater has been tested and evalua...

Страница 2: ......

Страница 3: ...injury or loss of life GENERAL HAZARD WARNING Failure to comply with the precautions and instructions provided with this brooder can result in Death Serious bodily injury or burns Property damage or...

Страница 4: ...te distributor or the L B White Co Inc for assistance or if you have any questions about the use of the heater or its application The L B White Co Inc has a policy of continuous product improvement It...

Страница 5: ...applicable 1 There are other factors that will affect the quantity of animals each heater can cover These include building ventilation and control systems building insulation building size and populat...

Страница 6: ...hing Symptoms of improper combustion affecting livestock can be disease lower feed conversion or death Asphyxiation Hazard Some p people c cannot s smell w well S Some p people c cannot smell t the o...

Страница 7: ...uired have a qualified gas heater service agency replace the complete part Do not attempt to repair 5 This heater is intended for the heating of livestock in agricultural animal confinement buildings...

Страница 8: ...ttings and adapters upstream of the gas control with approved gas leak detectors In the event a gas leak is detected check the components involved for cleanliness and proper application of pipe compou...

Страница 9: ...s designed for either L P vapor withdrawal or natural gas depending on model number Do not use this heater in an LPG liquid withdrawal system Do not permit LPG in liquid form to enter the heater at an...

Страница 10: ...the elastic on the filter and slide the filter over the sleeve Make sure the elastic of the filter is covering the top of the sleeve and that the seam of the filter is perpendicular to the canopy edge...

Страница 11: ...fully clogged with dust and dirt A dust choked filter will restrict the combustion air causing improper combustion Signs of improper combustion include backflashing of flame into the venturi tube yel...

Страница 12: ...ill occur 5 Set the building s temperature control to desired temperature This heater includes a spark ignition control module for purposes of controlling the timing of the ignition process of the hea...

Страница 13: ...ou can no longer feel heat coming from the heater canopy or combustion cones 2 Using a soft bristle brush brush off all exterior surfaces of the heater Pay particular attention to the air inlet hole o...

Страница 14: ...ny debris that may have accumulated 2 The a appliance a area s shall b be k kept c clear a and f free f from combustible m materials g gasoline a and o other flammable v vapors a and l liquids 3 Regul...

Страница 15: ...rom the orifice body by turning counter clockwise 6 Use compressed air to clean the orifice hole Do not push or poke any small file broach etc through orifice holes Doing so may enlarge the hole causi...

Страница 16: ...sconnect the high voltage ignition lead 10 Remove the connector nut from the ignition cable This same nut will be slid over the replacement ignition cable and used to create a water tight connection a...

Страница 17: ...ater top 6 Remove the igniter from the heater The igniter rod and its insulating ceramic body must be rigid within its mounting bracket If the igniter rod or its body are capable of movement the ignit...

Страница 18: ...e heater with a bypassed high limit switch may lead to overheating possibly resulting in a fire with subsequent damage to the heater building damage or loss of livestock TERMINAL MOUNTING LEG RESET BU...

Страница 19: ...as control valve Tighten securely See Fig 15 2 Connect the gas supply hose to the hose fitting on the test kit Tighten securely See Fig 15 3 Reconnect the heater to its electrical supply 4 Open the ma...

Страница 20: ...oblem is identified by the flow chart OPERATION SEQUENCE A call for heat occurs from building thermostat Line voltage is sent from building s temperature control to heater s ON OFF switch Switch sends...

Страница 21: ...High Limit Switch and Determine Cause of Tripping No No Is ON OFF Switch on Heater Positioned to ON Position the Switch to ON Yes No Is Proper Voltage Supplied to Heater Power Cord Provide Proper Vol...

Страница 22: ...ed Methods in this Owner s Manual No No I s Heater s Venturi Tube Reasonably Clean Clean Heater According to Prescribed Cleaning Methods in this Owner s Manual Yes No Is Flame Sense Ground Lead Proper...

Страница 23: ...in this Owner s Manual Yes No Is Dust Filter Clean Are Inner Cone Inlet Venturi Injector Body or Burner Orifice Plugged Clean all Components According to Cleaning Instructions in Owner s Manual If Com...

Страница 24: ...LACK GREEN WHITE SPARK IGNITION CONTROL NOTE POWER CORD IS CONNECTEDTO THERMOSTAT OR BUILDING ENVIRONMENTAL CONTROL SYSTEM ELECTRICAL CONNECTION DIAGRAM N1 N2 GND L1 MV ON OFF SWITCH POWER CORD GAS CO...

Страница 25: ...ignition control systems Ignites gas by spark Ignition Control Module Electronic device which controls the ignition sequence and operation of the heater Injector Body Allows combustion air to be drawn...

Страница 26: ...Parts Identification PARTS SCHEMATIC 11 4 5 10 34 6 17 8 26 32 25 37 27 28 22 35 24 23 31 30 7 31B 1 31A 29 3 9 2 12 36 20 16 21 13 41 1 14 19 18 33 39 42 40 38 25...

Страница 27: ...n 25 Orifice Burner L P Gas 310 21562 310 20573 Natural Gas 310 09776 310 21000 26 Injector Body w Air Register Plate L P Gas 500 21838 500 20672 Natural Gas 500 21837 500 21559 27 Retaining Screw for...

Страница 28: ...te o of p purchase by t the e end u user Warranty is automatic if a component is found defective within 12 months of the date code marked on the part If the defect occurs more than 12 months later tha...

Отзывы: