REGULATOR
NIPPLE
VALVE, MANUAL
SHUT-OFF
GAS HOSE
ADAPTER
SEDIMENT TRAP
TO CONTROL
VALVE INLET
REGULATOR VENT
GAS FLO
W
Assemble the tee, nipples and cap together and
tighten securely. See Fig. 5. The sediment trap
assembly must always be mounted in a vertical
position. Make sure pipe thread compound that is
resistant to both L.P. gas and natural gas is used
in making all connections.
Check all connec-
tions for gas leaks using approved gas
leak detectors.
FIG. 5
Sediment Trap Assembly
NIPPLE
HOSE ADAPTER
TEE
NIPPLE
CAP
TO GAS CONTROL
VALVE INLET
Manual Shut-off Valve,
Hose & Regulator
Assembly
1. Always use approved pipe thread compound
suitable for use with L.P. gas or natural gas on
the threaded connections.
2. Assemble the components together accord-
ing to the
fi
gure. This view is to show general
assembly of the components only. The regulator
must always be mounted so its vent, regardless
of location on the regulator, is always pointed
downward.
3. Tighten all connections securely.
4. Check all connections for gas leaks
using approved gas leak detectors.
FIG. 6
Содержание Guardian Series
Страница 46: ...Guardian with Smart Sense www lbwhite com Owner s Manual Guardian 46 Notes...
Страница 47: ...Guardian with Smart Sense Owner s Manual Guardian 47 Notes...
Страница 94: ...Guardian con Smart Sense www lbwhite com Manual del usuario Guardian 46 Notas...
Страница 95: ...Guardian con Smart Sense Manual del usuario Guardian 47 Notas...
Страница 142: ...Guardian avec Smart Sense www lbwhite com Manuel du propri taire Guardian 46 Remarque...
Страница 143: ...Guardian avec Smart Sense Manuel du propri taire Guardian 47 Remarque...