background image

 

 

K2_RM_EN_0.5

 

w w w . l - a c o u s t i c s . c o m

 

7   /   52

 

 

2

 

MECHANICAL SAFETY 

2.1

 

Mechanical limits 

The K2 rigging system complies with 2006/42/EC: Machinery Directive. It has been designed following the guidelines of 
BGV-C1. 
2006/42/EC: Machinery Directive specifies a safety factor of 4:1 against the rupture. The limits specified in the tables 

below correspond to deployments with a safety factor of 4:1 or higher. Refer to SOUNDVISION for the safety factor 
of a specific deployment. 
The 

safe  limit

  gives  the  maximum  number  of  elements  for  which  the  safety  factor  is  always  compliant  with  the 

2006/42/EC: Machinery Directive, regardless of the other deployment parameters (site angles, inter-enclosure angles, 
etc.). 
The 

maximum limit

 gives the maximum number of elements for which the safety factor can be compliant with the 

2006/42/EC: Machinery Directive, when the other deployment parameters provide the best mechanical conditions.

 

Ground-stacked 

 

Safe limit 

Maximum limit 

K2 on K1-SB with K2-BUMP 

4 K2 

6 K2 

Flown 

 

 

Safe limit 

Maximum limit 

K2-BUMP 

K2-BUMP + K2-BAR 

16 K2 

14 K2 + 2 LA-RAK 

12 K1-SB + 1 LA-RAK 

24 K2 

24 K2 + 2 LA-RAK 

16 K1-SB + 2 LA-RAK 

K2-LINK under K1-BUMP 

16 K2 

24 K2 

 

 

SOUNDVISION and mechanical safety 

To  deploy  more  elements  than  the  safe  limits,  or  when  mixing  different  type  of  loudspeaker  enclosures 

within  the  same  array,  always  model  the  system  in  SOUNDVISION  before  installation,  and  check  the 
Mechanical Data section for any stress warning or stability warning. 

2.2

 

Assessing mechanical safety 

In order to assess the actual safety of any array configuration before implementation, refer to the following warnings: 

 

Rated working load limit (WLL) is not enough 

The rated WLL is an indication of the element resistance to tensile stress. For complex mechanical systems 
such as loudspeaker arrays, WLLs cannot be used per se to determine the maximum number of enclosures 

within an array or to assess the safety of a specific array configuration. 

 

Mechanical modeling with SOUNDVISION  

The working load applied to each linking point, along with the corresponding safety factor, will depend on 
numerous variables linked to the composition of the array (type and number of enclosures, splay angles) 

and the implementation of the flying or stacking structure (number and location of flying points, site angle). 
This  cannot  be  determined  without  the  complex  mechanical  modeling  and  calculation  offered  by 

SOUNDVISION 

 

Assessing the safety with SOUNDVISION 

The  overall  safety  factor  of  a  specific  mechanical  configuration  always  corresponds  to  the  lowest  safety 
factor  among  all  the  linking  points.  Always  model  the  system  configuration  with  the  SOUNDVISION 

software and check the Mechanical Data section to identify the weakest link and its corresponding working 
load. By default, a 

stress warning

 will appear when the mechanical safety goes beyond the recommended 

safety level. 

 

Safety of ground-stacked arrays in SOUNDVISION 

For  ground-stacked  arrays,  a  distinct 

stability  warning

  is  implemented  in  SOUNDVISION.  It  indicates  a 

tipping hazard when the array is not secured to the ground, stage or platform. It is user responsibility to 

secure the array and to ignore this warning. 

 

Consideration must be given to unusual conditions 

SOUNDVISION  calculations  are  based  on  usual  environmental  conditions.  A  higher  safety  factor  is 
recommended with factors such as extreme high or low temperatures, strong wind, prolonged exposition 

to salt water, etc. Always consult a rigging specialist to adopt safety practices adapted to such a situation. 

Содержание WST K2

Страница 1: ...K2 WST enclosure RIGGING MANUAL VERSION 1 0 K2_RM_EN_1 0 w w w l a c o u s t i c s c o m 1 52 ...

Страница 2: ... warnings in Mechanical Data section 9 Be cautious when flying a loudspeaker array Always verify that no one is standing underneath the loudspeaker array when it is being raised As the array is being raised check each individual element to make sure that it is securely fastened to the adjacent element Never leave the array unattended during the installation process As a general rule L ACOUSTICS re...

Страница 3: ...an be set with laser like accuracy up to a generous 10 allowing the optimization of the vertical coverage with SPL smoothly spread across the audience Horizontally the K2 coverage pattern can be adjusted to sector and match any audience or specific room geometries Four different settings are possible two symmetric 70 or 110 and two asymmetric 90 as 35 55 or 55 35 Thanks to its full range capabilit...

Страница 4: ...ing 14 4 2 Flying 15 5 SUBSET PROCEDURES 17 Preparing a block of 4 K2 17 PROCEDURE A Preset the inter enclosure angles 19 PROCEDURE B Stacking K2 on K2 BUMP 20 PROCEDURE C Attaching K2 BAR on K2 BUMP 23 PROCEDURE D Attaching a block of four K2 under K2 BUMP 25 PROCEDURE E Attaching a block of four K2 under K2 27 PROCEDURE F Attaching a block of four K2 under a K1 system element 31 PROCEDURE G Atta...

Страница 5: ...rovided with two bow shackles WLL 3 25 t K2 BAR Rigging bar designed to provide a wider range of site angles for the K2 BUMP Provided with two bow shackles WLL 3 25 t K1 DELTA Rigging plate designed to be used optionally with the K2 BUMP to adjust the azimuth angle of flown K2 K1 K1 SB arrays K2 BUMPFLIGHT Flight case dedicated to the rigging elements of the K2 system In order to be used as storag...

Страница 6: ... MANUAL VERSION 1 0 K2_RM_EN_1 0 w w w l a c o u s t i c s c o m 6 52 K2 K1 SB LA RAK K2 BUMP K2 BAR K2 LINK K1 DELTA K2 RACKMOUNT K2 CHARIOT LA SLING2T K2 BPCHAIN SOUNDVISION Main components involved in the K2 rigging process ...

Страница 7: ...gh The rated WLL is an indication of the element resistance to tensile stress For complex mechanical systems such as loudspeaker arrays WLLs cannot be used per se to determine the maximum number of enclosures within an array or to assess the safety of a specific array configuration Mechanical modeling with SOUNDVISION The working load applied to each linking point along with the corresponding safe...

Страница 8: ... with the K1 rigging system 3 1 Elements for enclosure rigging On both sides the K2 enclosure integrates two arms to connect to another element of the rigging system such as an enclosure or to a flying frame At the front a rotating arm provides a fixed point around which the enclosure can freely rotate until its connection at the rear At the rear a sliding arm allows the inter element angle settin...

Страница 9: ...portation the blocks must have an inter enclosure angle of 10 to avoid any separation of the enclosures This angle must be set using the enclosure rear rigging arm pin The automatic locking system must remain unloaded The K2 CHARIOT rear rigging arm must be at its 15 site angle position TIPPING HAZARD If the enclosures are not pinned at 10 they can separate at the back causing the stack to tip ove...

Страница 10: ...r SOUNDVISION model to know which holes to use With K1 SB and a single motor the hole no 2 provides a 0 site angle By adding a K2 BAR to the K2 BUMP the site angle range can be increased 21 holes are available on the K2 BAR which can be attached to the K2 BUMP as a rear or a front extension and in position A or B thus offering a total of 84 discrete positions for pick up points The rear extension ...

Страница 11: ...MP Alternative Two K2 BAR attached on the sides The K2 system can be flown under a K1 system element K1 K1 SB or K1 BUMP The K2 LINK is designed to make the rigging systems compatible It provides three holes and therefore three angles between the top K2 enclosure and the bottom K1 element 0 25 2 5 and 5 ...

Страница 12: ... K2 RACKMOUNT is designed to stack one or two LA RAK on top of a flown array It is composed of four rails and a stabilizer The rails are screwed on the K2 BUMP Their number and position depend on the number of racks The K2 RACKMOUNT must be used along with either one or two K2 BAR 1 LA RAK 2 rails 2 K2 BAR 2 LA RAK 4 rails 1 K2 BAR ...

Страница 13: ...are mounted side by side the stabilizer is used to prevent the assembly from tipping or toppling over The stabilizer traps one of the chains used to lift the assembly 0 site angle 30 positive site angle Refer to APPENDIX A PICKUP POINTS GUIDELINES for more information ...

Страница 14: ... are visible on the front and on both sides of the array K2 enclosures on K1 SB Stack as many K1 SB enclosures as necessary Refer to the K1 rigging manual to set up the K1 SB part of the array Position and attach a K2 BUMP on the K1 SB stack Refer to PROCEDURE H Position and attach an upside down K2 on the K2 BUMP and add as many K2 enclosures on top of the first one Refer to PROCEDURE C ...

Страница 15: ... If necessary stack one or two LA RAK on the K2 BUMP Refer to PROCEDURE I Refer to APPENDIX A when stacking only one LA RAK Attach the shackles Refer to SOUNDVISION for the number and position of the shackles Lift the assembly so you can position a block of four K2 under it Attach the block of four K2 to the K2 BUMP Refer to PROCEDURE E Verify that the rear rigging arms are secured by pins and tha...

Страница 16: ...o SOUNDVISION for the number and position of the shackles Lift the assembly so you can position a block of K1 SB under it Attach the K1 SB block to the K2 BUMP Refer to PROCEDURE H Repeat the last two steps until the K1 SB array is complete K2 array setup Prepare all the blocks of 4 K2 necessary to build the array If a block is not built already refer to PROCEDURE A Preset the inter enclosures ang...

Страница 17: ... a K2 enclosure on K2 CHARIOT Fully rotate the rear rigging arms of the K2 CHARIOT Position the K2 enclosure on the K2 CHARIOT dolly Secure the enclosure at the front using the LINK hole Lift the rear of the enclosure and rotate the dolly rear rigging arm in its upward position Secure the enclosure using the LINK hole ...

Страница 18: ...osure on the first one Keep holding the enclosure in position with the handles until the front rigging arm is secured While holding the handle rotate the front rigging arm and secure it with both LINK pins Slide the rear rigging arm and secure it with both pins in the LINK and 10 holes 3 Make sure the automatic locking system button is unloaded If the button has been pressed pull to disengage the ...

Страница 19: ... i c s c o m 1 9 52 Preset the inter enclosure angles PROCEDURE B On both sides Remove the pin from its current angle hole Position the pin at the chosen angle hole and slide the rigging arm until the pin goes in Press the lock button ...

Страница 20: ...UMP PROCEDURE C 1 Prepare the K2 block top enclosure and turn it upside down on the K2 BUMP Take out and lock the rear and front rigging arms Define the K2 line site angle with the rear rigging arm Select a value between 0 25 and 7 5 and substract 3 to obtain the final site angle Remove the lower rear and front pins ...

Страница 21: ...nd rear rigging arm to the K2 BUMP Slide the front rigging arm up and down to align the holes Secure the front rigging arm to the K2 enclosure Raise the enclosure to align the holes Push the locking system button to unblock the lock 3 Prepare the K2 block top enclosure Adjust the inter enclosure angle with the rear rigging arm Remove the lower front and rear pins ...

Страница 22: ...2 Secure the front and rear rigging arm to the lower K2 enclosure Secure the front and rear rigging arm to the K2 BUMP Slide the front rigging arm up and down to align the holes Secure the front rigging arm to the top enclosure Raise the top enclosure to align the holes Push the locking system button to unblock the lock 5 Repeat steps 3 to 5 until the line is complete ...

Страница 23: ...K2_RM_EN_0 5 w w w l a c o u s t i c s c o m 2 3 52 Attaching K2 BAR on K2 BUMP PROCEDURE D 1 Refer to your SOUNDVISION model to identify the extension and position of the bar ...

Страница 24: ... K2_RM_EN_1 0 w w w l a c o u s t i c s c o m 2 4 52 2 Remove the pins and lift the K2 BAR using the motor 3 Turn the K2 BUMP FLIGHT 90 lower the K2 BAR and pin it according to the chosen flying option position A or B in front or rear extension ...

Страница 25: ...rming this procedure Refer to PROCEDURE B Rotate the arm and secure it with the K2 BUMP pin Lower the K2 BUMP and secure the connection with the K2 pin If you cannot insert the pin move the frame back and fortt 3 Lower the rear of the K2 BUMP 4 Attach the rear rigging arm to the frame Slide the arm to its 5 position Secure the arm with the frame pin Preset the angle at 5 with the enclosure pin Do ...

Страница 26: ... K2_RM_EN_1 0 w w w l a c o u s t i c s c o m 2 6 52 5 Raise the array to lock the enclosures 6 Remove the K2 CHARIOT Hold the dolly with one hand Remove the back pin on both sides Hold the dolly with one hand Remove the front pin on both sides ...

Страница 27: ...nclosure angles Preset the K2 inter enclosure angles before performing this procedure Refer to PROCEDURE B Rotate the arm to align its hole with the K2 rigging hole Pin the arm in the LINK hole of the flown array Lower the flown array and secure the assembly with the LINK pin If you cannot insert the pin move the flown array back and forth with enclosure handle ...

Страница 28: ...osure RIGGING MANUAL VERSION 1 0 K2_RM_EN_1 0 w w w l a c o u s t i c s c o m 2 8 52 8 Lock the inter enclosure angles of the block Raise the array The lower K2 enclosures swing and the latches automatically lock ...

Страница 29: ...eels inside the dolly Pull back the bottom enclosures while lowering the array until the array and the top enclosure of the block are in contact Slide the arm upward and secure it with the pin using the LINK hole Position the pin at the entrance of the chosen angle hole and slide the rigging arm until the pin goes in Press the lock button ...

Страница 30: ...a c o u s t i c s c o m 3 0 52 10 Raise the array to lock the inter enclosure angle The latches automatically lock 11 Remove the K2 CHARIOT Hold the dolly with one hand Remove the back pin on both sides Hold the dolly with one hand Remove the front pin on both sides ...

Страница 31: ...nter enclosure angles before performing this procedure Refer to PROCEDURE B 1 Attach the front rigging arm on both sides Rotate the arm to align its hole with the K1 K1 SB rigging hole Pin the arm on the flown array Lower the flown array and secure the assembly with the LINK pin If you cannot insert the pin move the flown array back and forth with enclosure handle ...

Страница 32: ...K2 WST enclosure RIGGING MANUAL VERSION 1 0 K2_RM_EN_1 0 w w w l a c o u s t i c s c o m 3 2 52 2 Lock the inter enclosure angles Raise the array ...

Страница 33: ...he K2 LINK interfaces to the K1 K1 SB Turn the wheels inside the dolly Pull back the bottom enclosures while lowering the array until only the front wheel touches the ground On both sides attach a K2 LINK at the back of the K1 SB enclosure Do not pin K2 LINK on K2 ...

Страница 34: ...MANUAL VERSION 1 0 K2_RM_EN_1 0 w w w l a c o u s t i c s c o m 3 4 52 4 Attach the K2 LINK to the K2 enclosure Lower the array Push the K2 LINK to guide it into the K2 rigging Secure the K2 LINK on the K2 rigging middle hole 5 ...

Страница 35: ..._0 5 w w w l a c o u s t i c s c o m 3 5 52 5 Remove the K2 CHARIOT Raise the array Hold the dolly with one hand Remove the back pin on both sides Hold the dolly with one hand Remove the front pin on both sides ...

Страница 36: ... BUMP PROCEDURE H 1 Slide out K1 SB front rigging arm and pin it at 0 on both sides 2 Attach the K2 BUMP to the K1 elements block Remove the K2 BUMP rear and front pins on both sides Lower the K2 BUMP so it rest on the topmost enclosure Rotate the rear rigging arm and pin it on the frame Pin the front rigging arm on the frame ...

Страница 37: ...with 13 mm hex socket 1 Remove the nuts and bolts from the K2 RACKMOUNT rails 2 Position and secure as many rails as necessary on the K2 BUMP 1 LA RAK 2 LA RAK 3 Secure the rails on the K2 BUMP Use the wrench with a 13 mm hex socket and the electric screwdriver Set the torque to 5 N m Before securing the side rails make sure the frame pins are on the outside ...

Страница 38: ...1 0 K2_RM_EN_1 0 w w w l a c o u s t i c s c o m 3 8 52 4 Install as many K2 BAR as necessary When installing a single K2 BAR at the center of the frame make sure the pins are inserted between the central bar of the frame and the closest rail ...

Страница 39: ...the LA RAK on the rails Secure the LA RAK with the coupling bars Insert the spring loaded safety in the LA RAK rails give a quarter turn and slide the bar until the safety locks into place Insert the coupling bars from the back for a negative angle rear extension from the front for a positive angle front extension Always insert so the metallic safety is pointed upward depending on the tilt angle ...

Страница 40: ...tacking 2 LA RAK side by side on K2 BUMP insert the stabilizer between the two racks Release the locking system by raising and turning the handle Insert the stabilizer on the side opposite to the K2 BAR from the front in rear extension from the rear in front extension Secure the stabilizer by locking the handle ...

Страница 41: ...A K2 system can be lifted using one or two motors One or two motors with K2 BUMP alone Two motors with K2 BUMP and one K2 BAR Two with K2 BUMP and two K2 BAR K2 BUMP with LA RAK OK NOT OK OK With a single LA RAK on top of a K2 BUMP always implement a bridle suspension using two LA SLING2T ...

Страница 42: ...g 8 mm Steels grade 8 Nominal length incl hooks 1 m 39 4 in Maximum sling angle βmax 60 Load rating 2 8 t for β 0 45 2 t for β 46 60 Never use slings shorter that 1 m 39 4 in One leg of the LA SLING2T must always be connected to the K2 BAR hole no 1 i e the closest to the array The other leg can be connected to holes no 11 to no 21 Refer to your SOUNDVISION simulation to choose the hole ...

Страница 43: ... w w l a c o u s t i c s c o m 4 3 52 K2 BUMP with no LA RAK OK NOT OK With two K2 BAR on a K2 BUMP do not implement a bridled suspension between the two bars Do not implement a bridled suspension on a single K2 BAR ...

Страница 44: ... rear pickup point The recommended space between the two lifting point is 1 m 33 ft By adjusting the height of both pickup points you can adjust the azimuth angle from 10 to 10 K2 BPCHAIN with a climbing hoist With a climbing hoist you must use a K2 BPCHAIN adjustable sling to prevent the chain bag from hanging in front of the top enclosures of the array Electric chain hoists Climbing hoists ...

Страница 45: ...TOOLCASE SSE ProSight TEQSAS LAP TEQ XLR 3 cable T20 Torx key Medium strength thread locker blue 1 Remove the four M4 Torx screws T20 from the plate 2 Put thread locker in the four threaded inserts 3 Position the LAP TEQ so it points toward the front of the K2 BUMP 4 Secure the LAP TEQ with the four screws 5 Connect the XLR 3 cable to the sensor 6 Follow the manufacturer instructions to calibrate ...

Страница 46: ... compression driver DOSC waveguide Nominal impedance LF 2 8 Ω MF 8 Ω HF 16 Ω RMS power handling LF 450 W MF 320 W HF 160 W Connectors IN 1 8 point PA COM LINK 1 8 point PA COM Rigging components Captive 4 point rigging system Inter enclosure angles 0 25 1 2 3 4 5 7 5 or 10 Dimensions Physical data Weight net 56 kg 123 2 lb Cabinet first grade Baltic birch plywood Finish Dark Grey brown proprietary...

Страница 47: ...int SpeakON Rigging components2 Captive 4 point rigging system Inter enclosure angles 0 0 5 1 1 5 2 2 5 3 4 or 5 Handles integrated in the cabinet Dimensions Physical data Weight net 83 kg 183 lb Cabinet Baltic birch plywood Finish Dark Grey brown Pantone 426C Pure white RAL 9010 Front Steel grill with anti corrosion coating Airnet acoustically neutral fabric Protection Rating IP45 Rigging compone...

Страница 48: ... u s t i c s c o m 4 8 52 K2 BUMP Description Rigging frame for K2 enclosure Dimensions Weight 42 3 kg 93 3 lb Material High grade steel with anti corrosion coating K2 BUMP FLIGHT Description Flight case for the K2 system rigging elements Dimension s Weight 105 kg 231 lb ...

Страница 49: ...tion Rigging bar for K2 BUMP Dimensions Weight 17 kg 37 5 lb Material High grade steel with anti corrosion coating K2 LINK Description Rigging interface for K2 and K1 K1 SB or K1 BUMP Dimensions Weight 1 8 kg 4 lb Material High grade steel with anti corrosion coating ...

Страница 50: ...ing interface for stacking one or two LA RAK on top of a K2 array flown with a K2 BUMP Dimensions Weight 3 3 kg 7 3 lb Material Steel with anti corrosion coating Description Stabilizer for two LA RAK side by side on top of a K2 array flown with a K2 BUMP Dimensions Weight 2 2 kg 4 lb Material Steel with anti corrosion coating ...

Страница 51: ...scription Rigging element for the K1 system Dimensions Weight 9 5 kg 21 lbs Material High grade steel with anti corrosion coating K2 CHARIOT Description Transport dolly for the K2 enclosure Dimensions Weight 50 kg 110 2 lb Material Steel with anti corrosion coating ...

Страница 52: ...o u s t i c s c o m 5 2 52 Document reference K2_RM_EN_1 0 Distribution date December 6 2013 2013 L ACOUSTICS All rights reserved No part of this publication may be reproduced or transmitted in any form or by any means without the express written consent of the publisher ...

Отзывы: