OUT CH TEMP (%)
OUT CH TEMP (%) (output channel temperature) displays the temperature measured at each individual amplier circuit
output as a percentage of the maximum operating temperature supported by the amplied controller: 90° C / 194° F =
100%.
In illustration
(p.48), the temperature of channels OUT 1 to OUT 4 is respectively 52, 53, 50,
and 48 % of the maximum values.
Refer to
(p.60) for information on the temperature-related messages.
MAINS VOLTAGE (V)
MAINS VOLTAGE (V) displays the minimum (Min), average (Avg) and maximum (Max) voltage of the connected power
supply, measured over the past 1.5 seconds, to help visualize if the power supply is undersized or if drops in voltage are
occurring.
Ideally, the average value should correspond to the power supply nominal voltage, and minimum and maximum values
should not exceed ± 10 % of the nominal voltage.
In illustration
(p.48), the average is 230 V, minimum is 210 V, and maximum is 255 V.
To reset the measurement, press the OK key.
Refer to
(p.60) for information on the power supply related messages.
ETHERNET LINKS
ETHERNET LINKS displays the current status of the link of each Ethernet port.
The status includes, for each port:
— the Ethernet link speed: 10M (for 10 Mbits/s), 100 (for 100 Mbits/s) or 1G (for 1 Gbits/s)
— the communication mode: HALF (for half-duplex) or FULL (for full-duplex)
If no connection has been established, the displayed status is DOWN.
Possible causes: no cable connected to the port, faulty cable connected to the port, cable connected to the port but no
device connected at the other end of the cable, port failure.
In illustration
(p.48), port 1 has a speed of 1 Gbits/s, port 2 has a speed of 100 Mbits/s, and
both are in full-duplex mode.
FIRMWARE
FIRMWARE displays the version number of the amplied controller onboard rmware.
Press the encoder wheel to display the fourth digit and the build date (in the YYYYMMDD format).
‽FIRMWARE ‼
V1.7.0
‽FIRMWARE 20160217
V1.7.0.8
Network
Always ensure that all LA12X amplied controllers used in a given network run the same rmware version.
49
LA12X user manual (en) version 2.0
Содержание LA12X
Страница 1: ...LA12X user manual en...
Страница 5: ...Latency 70 Remote control and monitoring 70 Physical data 70 Approvals 71 5...
Страница 16: ...Installation Refer to the LA RAK II user manual LA12X user manual en version 2 0 16...
Страница 71: ...Approvals Approvals 71 LA12X user manual en version 2 0...
Страница 72: ......