Operation
MONITORING & INFO
The MONITORING & INFO menu provides real-time measurements and information on the amplied controller:
— For each output channel:
— real-time RMS output voltage (in percentage of the maximum value supported by the connected transducer
section)
— output temperature (in percentage of the operating range)
— minimum, maximum and average voltage of the connected power supply
— Ethernet ports current status
— version numbers of the amplied controller onboard rmware and preset library
— amplied controller's MAC address
— amplied controller's hardware version
— the ENCLOSURE CHECK function
MONITORING & INFO
‾SPK HANDLING (%) ‼
12% 10% 13% 11%
‽OUT CH TEMP (%) ‼
52% 53% 50% 48%
‽FIRMWARE ‼
V1.7.2
‽PRESET LIBRARY ‼
V5.6
‿ENCLOSURE CHECK ‼
PRESS OK TO START
‽MAC ADDRESS ‼
00:1B:92:01:90:3A
‽HARDWARE INFO ‼
ID5
‽MONITORING & INFO ‼※
OPTIONS
OK
‽MAINS VOLTAGE (V) ‼
Min:210 Avg:230 Max:255
‽ETHERNET LINKS ‼
1: 1G FULL 2:100 FULL
SPK HANDLING (%)
SPK HANDLING (%) (speaker handling) displays the RMS voltage measured at each individual amplier circuit output as
a percentage of the maximum voltage supported by the connected speaker section.
In illustration
(p.48), the RMS voltage of channels OUT 1 to OUT 4 is respectively 12, 10,
13, and 11 % of the maximum values.
LA12X user manual (en) version 2.0
48