Corrective maintenance
Screws and fasteners repair kit
This repair kit contains all the screws and fasteners necessary to perform one maintenance procedure on L-ISA Processor
II.
G03664
KR external screws L-ISA Processor II
×2
×2
×2
×23
1352
S184
S100059
S100236
spacer for rear bracket
M4×8 hex socket head cap
screw
M4×12 Torx
M3×10 Torx
×4
×12
S100214
S100085
M3.5×16 Torx
M4×10 Torx
Troubleshooting and diagnosis
For any issue, consider the diagnosis tables for the possible causes and inspection procedures (if any).
Power issues
The processor does not turn on.
possible cause
diagnosis/procedure
power cord is not connected
• check that the power cord is connected to mains
• check that the IEC C13 connector is properly connected and
locked
mains failure or incompatible voltage
check that mains are available and that voltage is compatible (100 V
AC - 240 V AC ± 10%, 50 Hz - 60 Hz)
power cord is damaged
inspect the power cord, and replace it if necessary
other causes
contact L-Acoustics
Interface issues
Start-up sequence fails (SYNC / WORD / IN / OUT LEDs ash in red).
possible cause
diagnosis/procedure
display driver failure, preventing the DSP from
starting
1.
Disconnect any device from the HDMI port.
2.
Disconnect the processor from the mains.
3.
Connect the processor to the mains.
4.
Power on the processor.
hard drive failure
contact L-Acoustics
In case of emergency, refer to
Rebooting L-ISA Processor II using the
(p.27).
L-ISA Processor II owner's manual (EN) version 1.0