Inspection and preventive maintenance
7.
Depending on the displayed results, follow the instructions in the table.
result
interpretation
instructions
OK
measured impedance is within expected range
enclosure is in working order electrically
?
unsupported preset family
only supported enclosures should be tested
NC
Not Connected
if cables are connected:
a.
inspect the cables and connections
b.
(p.67)
NOK
measured impedance is not within expected range
UNDEF
measured impedance is undened
a.
check that all the prerequisites are met, in
particular that the loaded preset corresponds
to the connected speaker's family
b.
inspect the cables and connections
c.
(p.67)
8.
Under NC, NOK and UNDEF results, press and hold the corresponding OUT key.
The amplied controller displays:
• the tested frequencies,
• information on the measured impedance:
• OPEN for open circuit (found in NC results),
• SHORT for short circuit (found in NOK results), or
• a percentage of variation from the expected range (found in NOK and UNDEF results)
• the number of operational transducers out of the total
Low variations from the expected range are acceptable: displayed percentage can be different from 0 and all
transducers considered operational.
A10 owner's manual (EN) version 1.1
67
Содержание A10
Страница 1: ...A10 owner s manual EN ...
Страница 38: ...Rigging system description 38 A10 owner s manual EN version 1 1 ...
Страница 121: ...Corrective maintenance If the speaker gasket is damaged remove and replace it A10 owner s manual EN version 1 1 121 ...
Страница 143: ...L Acoustics 13 rue Levacher Cintrat 91460 Marcoussis France 33 1 69 63 69 63 info l acoustics com www l acoustics com ...