DIAGNOSTIC MESSAGES
Message Description
Corrective
Action
HTR TEMP LMT
Overheat – The spa has shut down.
One of the sensors has detected that
the spa water is 118°F (47.8°C).
DO NOT ENTER THE WATER.
Remove the spa cover and allow water
to cool. Once the heater has cooled,
reset by pressing any key. If the spa
does not reset, power off spa and call
for service.
SPA TEMP LMT
Overheat – The spa has shut down.
One of the sensors has detected that
the spa water is 118°F (47.8°C).
DO NOT ENTER THE WATER.
Remove the spa cover and allow water
to cool. At 107°F (41.7°C), the spa
should automatically reset. If the spa
does not reset, power off spa and call
for service.
FREEZE COND
Ice – Potential freeze condition
detected.
No action required. All equipment will
activate regardless of spa status.
SENSOR A
SERVICE RQD
Spa is shut down. The sensor that is
plugged into the sensor A jack is not
working.
This error may appear temporarily in an
overheat condition. If the problem
persists, call for service.
SENSOR B
SERVICE RQD
Spa is shut down. The sensor that is
plugged into the sensor B jack is not
working.
This error may appear temporarily in an
overheat condition. If the problem
persists, call for service.
SENSOR SYNC
Sensors are out of balance. If
alternating with spa temperature, it may
just be a temporary condition.
If the problem persists, call for service.
SENSOR SYNC
SERVICE RQD
Sensors are out of balance. The spa is
shut down.
Reset by pressing any key. If the
problem persists, call for service.
HTR FLOW LOW
A significant difference between
temperature sensors has been
detected. This could indicate a flow
problem.
Add water if necessary. If water level is
normal, make sure the pumps have
been primed (see page 13).
LOW FLOW
Persistent low flow problems. (Displays
on the fifth occurrence of
HTR FLOW LOW
message within 24 hours.) Heater is
shut down, but other spa functions
continue to run normally.
Follow action required for
HTR FLOW LOW
message. Heating capability of the spa
will not reset automatically, press any
key to reset.
HEATER MAY BE
DRY—
WILL RETEST
SHORTLY
Inadequate water detected in the
heater.
Add water if necessary. If water level is
normal, make sure the pump has been
primed (see page 13). Press any key to
reset. This message will reset within 15
minutes.
Heater dry
service rqd
Inadequate water detected in heater.
(Displays on third occurrence of the
above message.) Spa is shut down.
Follow action required for the above
message. Spa will not automatically
reset. Press any key to reset manually.