2-8
Operation
Battery Calibration In Progress...
Auto-Off When Done
Press Any Key to Abort
Battery Requires Charge
5. Press the Menu button.
6. Rotate the knob until Battery Calibration is highlighted in the menu
bar.
7.
Press the knob to Confirm battery calibration. The following screen
message appears:
8. Review the following if the calibration fails.
• The ambient temperature of the indicator must remain between
+5 C and +40 C (+41 F and +104 F) during calibration.
• If the battery SOC is not > 90% the following message is shown
in the middle of the screen:
• If the battery needs to be charged. Reapply external power to
the indicator. When the battery is charged to greater than 95%
SOC, shut the ESI down for a rest period of 2 hours for battery
stabilization. After the rest period reapply power and go to step
2 above.
• The Cal Due battery indicator continues to be observed during
normal operation if the calibration procedure is aborted.
7. When calibration is complete, the indicator automatically powers
down. A 5 hour rest period is required for the battery calibration to
be successful.
CAUTION
APPLYING POWER TO THE INDICATOR BEFORE THE
END OF THE 5 HOUR REST PERIOD WILL INVALIDATE
THE BATTERY CAPACITY CALIBRATION.
Содержание ESI-500
Страница 1: ...Electronic Standby Instrument System Aviation Products Pilot s Guide for the ESI 500 MAG 500 ...
Страница 2: ......
Страница 10: ...Pilot s Guide viii This page intentionally blank ...
Страница 18: ...ESI 500 Pilot s Guide 1 8 Operation This page intentionally blank ...
Страница 34: ...ESI 500 Pilot s Guide 2 16 Operation This page intentionally blank ...
Страница 62: ...ESI 500 Pilot s Guide 3 28 Display Features This page intentionally blank ...
Страница 74: ...Pilot s Guide A 2 NOTES ...
Страница 75: ...Pilot s Guide A 3 NOTES ...