74
2. Be sure propane container has fuel and valve is open.
3.
Release thermostat from “OFF” position and onto “HEAT”
position.
4. Set temperature 5 to 8 degrees above room temperature.
5. Blower will start in 0 to 15 seconds, run for 30 seconds during
heat chamber “PURGE” cycle, removing propane vapor, if any.
6. Second cycle, blower continues to run, module board will: (a)
send spark to burner tube, (b) open valve in control to release
propane to burner tube.
7. Ignition attempt will be for 7 seconds.
8. Failing to ignite, board will make 2 more attempts to light and
then go to lockout.
9. If after (3) attempts with no ignition, drop thermostat to lowest
setting, wait 1 minute and repeat steps 4 to 7.
10. After burner tube lights, set thermostat to desired setting.
11. To shut burner down, move thermostat to lowest setting or
“OFF”.
12. Blower will continue to run for about 2 minutes until heat is
removed from chamber.
To Turn Appliance Off
1. Set the thermostat to the lowest setting, then move lever to
“OFF” position.
2. Turn off all electrical power to the appliance if service is to be
performed. ALL furnaces have a 12-volt DC switch built on the
furnace and must
be turned “ON” for furnace to operate. Some
models may have a wood panel cover in front of switch, making
it difficult to have access to it.
External Vents
Always be sure these vents are clear of any objects like screens, duct
tape, etc., BEFORE OPERATING.
Ducting
Wall or floor registers, and return air grills MUST be kept clear of any
obstructions. Any such restrictions will prevent the furnace from correct
operation. Closeable registers will reduce air flow. Never shut registers
off completely, possibly causing furnace to limit out and shut down.
Propane pressure, as defined in Chapter Four - Systems, is extremely
important. A dial gauge or U-tube manometer is required to perform tests
and adjustments. Pressure must be set at 11 inches w.c. (water column)
plus or minus 1/2 inch. Incorrect gas pressure can cause any appliance
Do not install screens over the vents for any reason. Screens
will become restricted, causing unsafe or inefficient operation.