7.mode save and call

7.5.1 Mode save

Click Save Mode in the main ribbon to eject the Save Mode Settings window, as shown in the

following image:

You can change the pattern as needed ID , that is, to save to the first few modes, you can also

change the schema name as needed. (excluding the pre-monitoring and hot-backup settings).

P

The device defaults to boot mode one data, so it is recommended to save the most commonly

used display mode data in the pattern 1 .

7.5.2 mode call

Click Left User Mode , click on the corresponding mode to invoke the display, in addition, if you

right-click user mode to change the mode name, make the pattern easier to remember and use.

As shown in the following illustration:

Содержание KLS24

Страница 1: ...KLS24 24 lan ports two in one video controller Version v1 1 release date November 2021 Manual ...

Страница 2: ...Version record Version Change details release time V1 0 first release 2021 10 25 V1 1 Correct size data 2021 11 18 ...

Страница 3: ... the case of lightning or long term use unplug the power plug 3 this equipment is not suitable for non professional operation debugging please use under the guidance of professionals 4 DO not plug any object from the vent hole of this device to prevent damage or accident 5 It is not advisable to place this equipment in near water or other humid places 6 It is not advisable to place this equipment ...

Страница 4: ...ION STEPS 11 7 VIDEO PROCESSOR SOFTWARE DEBUGGING INSTRUCTIONS 12 7 1 OPEN SOFTWARE 12 7 2 SOFTWARE CONNECTION 13 7 2 1 select NET connect 13 7 2 2 Select COM Connect 14 7 3 OUT PORT SETTINGS 15 7 4 OPEN WINDOW 17 7 MODE SAVE AND CALL 20 7 5 1 Mode save 20 7 5 2 mode call 20 8 CONTROL CARD SOFTWARE DEBUGGING INSTRUCTIONS 21 1 SOFTWARE CONNECTION 21 2 RECEIVING CARD PARAMETER SETTINGS 22 3 SCREEN C...

Страница 5: ...ignal source save mode open kystar control system software expert debug Receiving card debugging screen connection total save parameter 1 video processor setting 1 IP address change PC IP and KSV24 on the same network segment KLS24 default IP address 192 168 0 100 2 software connect open PC software to debug kystar software connect device select Ethernet to connect ...

Страница 6: ... the arrangement of the output ports according to the actual output 4 open window Click on the upper left corner to open a new screen or hold down the left mouse button and drag in the operation area When a rectangle is drawn release the left button and a window will be created Double click the signal source on the left to switch the signal ...

Страница 7: ...ystar control system of kystar software click kystar control system software enter control card debug interface first time debug KLS24 click 666888 in keyboard after open software select network cable direct connection mode select directly connected to sending device 2 On the receiving card interface add module configuration information through ...

Страница 8: ...re is a previously saved configuration file it can also be loaded on this interface and sent to the receiving card parameters 3 On screen connection interface set the number of card columns and card rows according to the positions of all receiving cards click the setting connection complete the connection according to the prompts and modify the load size of each receiving card ...

Страница 9: ...KLS24manual www kystar com cn 5 4 Finally after confirming that the screen is displayed normally click Solid All to complete all debugging operations of KLS24 ...

Страница 10: ...s necessary to display the screen of any size or complete computer desktop at will 4 With the continuous reduction of the distance between the LED screens and the continuous increase of the number of screen points the era of single card loading and single screen display of a single screen will soon cease to exist and more application requirements and display requirements will be highlighted LED la...

Страница 11: ...agement Group screen management the device supports two groups of screen management and the corresponding output port resolution of each group of screens can be set separately to meet the mixed control of various display terminals in special shaped screens and complex scenes Super Resolution zoom technology video compensation processing algorithm no size limit when the screen is reduced and retain...

Страница 12: ...s 4096 2160 60Hz or 7680 1080 60Hz supports custom resolution the horizontal width is up to 8000 pixels and the height is up to 4000 pixels DP1 2 1 The maximum supported resolution is 4096 2160 60Hz or 7680 1080 60Hz supports custom resolution the horizontal width is up to 8000 pixels and the height is up to 4000 pixels Output port Type quantity Specification LAN 24 LAN port used to transmit data ...

Страница 13: ...KLS24manual www kystar com cn 9 4 Working diagram ...

Страница 14: ... 60Hz module support DP1 2 HDMI2 0 input max support resolution 4096 2160 60Hz or 7680 1080 60Hz 2 Output board card 24 pcs lan cable out 3 Control board including power switch COM port network port USB 4 Power supply 100 240V AC 50 60Hz 6 6A not support backup power supply ...

Страница 15: ...onnect cable as shown in the figure connect the control computer to the LAN control port of the device through the network cable and connect the output network port of the KLS24 controller to the receiving card 3 Make sure that the wiring is correct and then power on and open the gold card debugging software The software can correctly identify the model of the sending card and the number of receiv...

Страница 16: ...he desktop open the software and go to the software start up page As shown in the following illustration The first use of no password direct click to determine if you set the user password requires the correct password to enter the software control settings Click OK to enter the software main interface As shown in the following illustration ...

Страница 17: ...twork port of the which can also be connected through a switch 2 Modify Local Area Connection IP In Windows system go to Start Control Panel View Network Tasks Change Adapter Settings you can find Local Area Connection right click Local Area Connection and select Properties the following dialog box will pop up double click Internet Protocol Version 4 TCP IPv4 and set the The data modification and ...

Страница 18: ...unication in software communication Select NET Connect and click directly OK if the connection succeeds a prompt box will pop up as shown in the following figure and click OK 7 2 2 Select COM Connect 1 Wiring Use random distribution RS230 RJ11 connector one end attached to the processor s COM1 Port one end is connected to PC Serial Port if no nine pin serial port to use serial port to turn USB Con...

Страница 19: ...n software communicates Select NET Connect and click directly OK if the connection succeeds a prompt box will pop up as shown in the following figure and click OK 7 3 Out port settings Click after device connection succeeds Primary Ribbon under Screen Configuration pop up screen parameter setting interface the six dotted field word box in the operation area corresponds to the device output port se...

Страница 20: ... and Columns set on your own above the layout diagram 1920 and the on the left 1080 the can be modified according to the actual number of load points double click the value to modify For example Screen size is 6016 2080 with six send cards with load size and arranged as shown in the following figure Then the screen parameter settings interface requires the following settings ...

Страница 21: ... after the click to determine return to the operating area 7 4 Open window Through the above settings has been the whole large screen stitching up gray area to represent the entire large screen the big screen how to display need to create a picture here to 2 Row 3 The column shows an example of how to create a picture Hold down the left mouse button and drag in the operation area and when you draw...

Страница 22: ...indow at the bottom Property Set the properties of the current window Full screen Toggle between panorama and local mode panorama is the input signal of the whole picture local is the input signal local image by changing the window properties of the input zoom to select the size and location of the local screen if not set and the window size is less than the resolution of the input signal the defa...

Страница 23: ...ch Screen parameters are set the current window size if you need the entire screen to play a screen the size of the window set to screen pixel size can be if you need to show the effect of multiple screens according to the actual situation to make adjustments When need to intercept the blue print area to play out in a window you need to set the horizontal vertical position of the window input zoom...

Страница 24: ...n also change the schema name as needed excluding the pre monitoring and hot backup settings P The device defaults to boot mode one data so it is recommended to save the most commonly used display mode data in the pattern 1 7 5 2 mode call Click Left User Mode click on the corresponding mode to invoke the display in addition if you right click user mode to change the mode name make the pattern eas...

Страница 25: ...eceiving card parameters and the screen connection 1 software connection Use the network cable to connect when debugging KLS24 for the first time after opening the software type 666888 on the keyboard select the network cable direct connection mode check the direct connection sending device and detect that the number of receiving cards is the actual number of on site loads to debug ...

Страница 26: ...to the width and height of the module the driver chip and the decoding chip the unit board loading file is made data line color The arrangement of red green and blue can be directly exchanged without resetting intelligently Draw settings The lamp panel is drawn and applied to small spacing and unconventional lamp panels Set up single card loading Receives the width and height of the cartridge load...

Страница 27: ...ule is generally adjusted to 20 83 too high has a great impact on the module itself and is troublesome to maintain 2 Reduce OE width The default is 32ns in units of 8 and it is reduced one by one note that too low will affect the low gray effect 3 Adjust the output gray level Conventional modules are generally adjusted to 12 14 12 represents 2 to the 12th power that is 4096 4 Appropriately reduce ...

Страница 28: ...to individually adjust the load and location information for each receiving card For alien items Save to file Save the display connection kcfg file separately Hub port offset Set the offset of the HUB port select the receiving card and click the port offset to set Debugging Tips Select the network port to directly change the width and height of all cards in the network port Click the number before...

Страница 29: ...he connection mode of video card video processor receiving card and large LED screen A The DVI VGA output port of the graphics card is connected to the DVI IN VGA IN input of the video processor the network port output of the video processor is connected to the terminal receiving card behind the screen through a network cable the receiving card connection control The respective part of the screen ...

Страница 30: ...he graphics card should be set If not the DVI port of the graphics card has no data output Setup steps Turn off the power supply of video processor reinsert the line from video card to video processor ATI graphics card reads and replicates automatically NVIDIA graphics card needs to enter the graphics card control center and set up multiple display double screen replicate mode Connection problems ...