![Kyocera Ri 4530 Copystar Скачать руководство пользователя страница 235](http://html1.mh-extra.com/html/kyocera/ri-4530-copystar/ri-4530-copystar_service-manual_2016540235.webp)
2BC/D
1-6-31
(5) Adjusting the longitudinal squareness (reference)
Perform the following adjustment if the copy image is longitudinally skewed (longitudinal squareness is not obtained).
Caution
Before making the following adjustment, output a 1 dot-LINE PG pattern in maintenance item U089 to use as the original
for the adjustment.
Perform adjustment of straightness when proper straightness cannot be obtained even if you perform “Adjusting the
registration/vertical conveying slack amount (P.1-6-19, 20)” first and then check the straightness of copy images.
Procedure
Figure 1-6-60
Figure 1-6-61
Mirror 2 frame
Screws
Yes
No
Press the start key and make
a test copy at 100% magnification.
Start
Remove the contact glass.
Loosen the two screws and
adjust the position of the
mirror 2 frame.
For copy example 1,
move the frame in the direction of
the white arrow ( ).
For copy example 2,
move the frame in the direction of
the black arrow ( ).
End
Is the image correct?
Place the original
on the contact glass.
Retighten the two screws and
refit the contact glass.
Original
Copy
example 1
Copy
example 2
Содержание Ri 4530 Copystar
Страница 1: ...SERVICE MANUAL Published in Feb 02 2BC70941 Revision 1 Ri 4530 5530 ...
Страница 76: ...2BC D 1 1 4 13 This page is intentionally left blank ...
Страница 100: ...1 4 35 2BC D 1 This page is intentionally left blank ...
Страница 142: ...2BC D 1 This page is intentionally left blank ...
Страница 173: ...2BC D 1 This page is intentionally left blank ...
Страница 187: ...2BC D 1 1 5 42 This page is intentionally left blank ...
Страница 355: ...2BC D 2 3 20 CN1 CN7 CN5 3 1 1 6 CN2 1 6 CN6 3 1 CN4 1 1 6 16 Figure 2 3 8 Scanner drive PCB silk screen diagram ...
Страница 374: ...2BC D 1 2 4 16 This page is intentionally left blank ...
Страница 380: ...2BC D 1 2 4 22 This page is intentionally left blank ...