2H9
2-3-2
Connector
Pin Signal
I/O
Voltage
Description
YC101
1
NEUTRAL
I
120 V AC
AC power input
Connected
to the AC
inlet
220 - 240 V AC
2
LIVE
I
120 V AC
AC power input
220 - 240 V AC
YC102
1
LIVE
O
120 V AC
Fuser heater lamp output
Connected
to the fuser
heater lamp
220 - 240 V AC
2
NEUTRAL
O
120 V AC
Fuser heater lamp output
220 - 240 V AC
YC103
1
+24V1
O
24 V DC
24 V DC power source
Connected
to the high
voltage
PWB
2
SGND
-
-
Ground
3
FAN
I
0/24 V DC
Left cooling fan motor: On/Off
4
THERM
O
Analog
Fuser thermistor detection voltage
5
+3.3V1
I
3.3 V DC
3.3 V DC power source
6
HEATN
I
0/3.3 V DC
Fuser heater lamp: On/Off
7
SLEEP
I
0/3.3 V DC
Sleep mode signal: On/Off
8
ZCROSS
O
0/3.3 V DC (pulse) Zero cross signal
9
+24V2
O
24 V DC
24 V DC power source (via interlock switch)
10
+24V2
O
24 V DC
24 V DC power source (via interlock switch)
11
PGND
-
-
Ground
12
PGND
-
-
Ground
YC104
1
+24V1
O
24 V DC
24 V DC power source
Connected
to the left
cooling fan
motor
2
FAN
O
0/24 V DC
Left cooling fan motor: On/Off
YC105
1
+3.3V1
O
3.3 V DC
3.3 V DC power source
Connected
to the fuser
thermistor
2
N.C.
-
-
Not used
3
THERM
I
Analog
Fuser thermistor detection voltage
YC106
1
+24V1
O
24 V DC
24 V DC power source
Connected
to the scan-
ner PWB
2
N.C.
-
-
Not used
3
GND
-
-
Ground
YC107
1
+24V1
O
24 V DC
24 V DC power source
Connected
to the power
source fan
motor
2
FAN
O
0/24 V DC
Power source fan motor: On/Off
YC108
1
-
-
-
Frame ground (Control PWB)
Connected
to the
ground ter-
minals
2
N.C.
-
-
Not used
3
-
-
-
Frame ground (Frame)
Содержание KM-2810
Страница 1: ...SERVICE MANUAL Published in May 2009 2H9SM060 First Edition KM 2810 ...
Страница 3: ...Revision history Revision Date Replaced pages Remarks ...
Страница 4: ...This page is intentionally left blank ...
Страница 10: ...This page is intentionally left blank ...
Страница 18: ...2H9 1 1 6 This page is intentionally left blank ...
Страница 22: ...2H9 1 2 4 5 Remove nine tapes Figure 1 2 5 Tape Tapes Tapes Tapes Tapes ...
Страница 24: ...2H9 1 2 6 This page is intentionally left blank ...
Страница 105: ...2H9 1 5 15 7 Unhook four hooks and then remove the scanner unit Figure 1 5 19 Scanner unit Hooks Hooks ...
Страница 138: ...2H9 1 5 48 This page is intentionally left blank ...
Страница 157: ...2H9 2 1 17 Figure 2 1 24 Paper exit section block diagram EXITN YC19 3 Fuser unit Exit sensor Control PWB ...
Страница 162: ...2H9 2 2 4 This page is intentionally left blank ...
Страница 174: ...2H9 2 3 12 This page is intentionally left blank ...
Страница 178: ...2H9 2 4 4 This page is intentionally left blank ...
Страница 179: ......
Страница 180: ......